• No results found

failure of closed reduction.

Closed reduction and percutaneous annulated screw fixation in the treatment of comminuted proximal humeral fractures

Closed reduction and percutaneous annulated screw fixation in the treatment of comminuted proximal humeral fractures

... suffered closed reduction failure or the fracture had re-displaced and underwent ORIF treatment, and the remaining 2 patients suffered humeral head splitting frac- tures involving the articular ...

7

Effect of phenylephrine spray on closed reduction of nasal fractures in patients under general anesthesia

Effect of phenylephrine spray on closed reduction of nasal fractures in patients under general anesthesia

... The findings of this study indicated a significant reduction in the amount of intraoperative bleeding in patients receiving phenylephrine spray. However, the amount of postoperative bleeding, the need for tampon ...

6

A comparative analysis between methods of open reduction and closed reduction in internal fixation of proximal tibia fractures

A comparative analysis between methods of open reduction and closed reduction in internal fixation of proximal tibia fractures

... are failure to reduce and maintain reduction of plateau surface, ligament laxity secondarily to an unrepaired collateral or cruciate ligament injury, and traumatic arthritis with loss of articular cartilage ...

136

Medium-term results following arthroscopic reduction in walking-age children with developmental hip dysplasia after failed closed reduction

Medium-term results following arthroscopic reduction in walking-age children with developmental hip dysplasia after failed closed reduction

... the failure rate of this treatment can be up to 50%. The high failure rate of closed reduction can be largely attrib- uted to excessive intra-acetabular contents such as hypertrophic ...

8

A comparative study of analysis of functional outcome of intra articular distal radius fractures treated with dynamic external fixator and locking compression plate.

A comparative study of analysis of functional outcome of intra articular distal radius fractures treated with dynamic external fixator and locking compression plate.

... About 47 patients with distal radius intraarticular fractures were treated, among which 5 patients had lost follow up and only 42 patients are included in the study. All of them were skeletally matured, came with pain, ...

135

Surgical Treatment of Lower Cervical Locked Facet  An Experience in 20 Cases

Surgical Treatment of Lower Cervical Locked Facet An Experience in 20 Cases

... The patients followed clinically and radiologically (with lateral cervical radio- graphy performed in the bed) until reduction is obtained. Traction at any point of time whenever there is evidence of distraction ...

12

Efficacy of traditional closed reduction versus closed reduction in conjunction with osteotomyin nasal bone fractures

Efficacy of traditional closed reduction versus closed reduction in conjunction with osteotomyin nasal bone fractures

... traditional closed reduction and closed reduction in conjunction with osteotomy regarding patient satisfaction and ...traditional closed reduction (traditional CR) (n=38) or ...

6

Comparative study of effectiveness of rush pin with long arm cast and dynamic compression plate in management of closed diaphyseal fracture of radius and ulna in adults

Comparative study of effectiveness of rush pin with long arm cast and dynamic compression plate in management of closed diaphyseal fracture of radius and ulna in adults

... elbow flexed 900 for the nailing of the ulna, whereas for radius, the arm was extended while making entry into the bone. Traction was applied to reduce the fragments. A 1cm incision at olecranon tip was made deep to the ...

6

Original Article Analysis of early imaging prediction signs of type 2 avascular necrosis of the femoral head after DDH treatment

Original Article Analysis of early imaging prediction signs of type 2 avascular necrosis of the femoral head after DDH treatment

... after closed reduction or simple open reduction or Salter’s pelvic osteotomy + open reduction were reviewed to find the early imag- ing signs of avascular necrosis of the femoral head proposed ...

7

Internal plate fixation versus plaster in displaced complete articular distal radius fractures, a randomised controlled trial

Internal plate fixation versus plaster in displaced complete articular distal radius fractures, a randomised controlled trial

... Methods/Design: This multicentre randomised controlled trial will randomise between open reduction and internal plate fixation (intervention group) and closed reduction and plaster immobilisation ...

8

Comparison of infraorbital nerve recovery after open and closed reduction of zygomaticomaxillary complex fractures

Comparison of infraorbital nerve recovery after open and closed reduction of zygomaticomaxillary complex fractures

... Ahmed with other coworkers concluded the superiority of using miniplate osteosynthesis for the better healing of infraorbital nerve in 2010 and majority of the patients (32.4%) in their study recovered in 4 months ...

5

On Locally b#-Closed Sets and Weakly b#-Closed Sets

On Locally b#-Closed Sets and Weakly b#-Closed Sets

... regular closed set and let G be a b # -open set containing ...regular closed we have A= cl(int(A)) ...regular closed. This proves (ii). Now to prove (iii). Let A be any closed set and let G be ...

16

Closed reduction and percutaneous k-wire fixation for distal end radius fractures

Closed reduction and percutaneous k-wire fixation for distal end radius fractures

... The patients were admitted to the hospital and were operated on as soon as possible, depending on the condition of the local tissue, hematoma, tissue oedema and other associated injuries. Under axillary block or general ...

5

—FMEA, Fuzzy FMEA, Discontinuous

—FMEA, Fuzzy FMEA, Discontinuous

... Abstract—A comparative study between fuzzy and common Failure Mode and Effect Analysis (FMEA) was performed on a Discontinuous Distillation Plant. Fuzzy FMEA provides a tool that can work in a better way with ...

6

Analysis of Boiler Tube Failure

Analysis of Boiler Tube Failure

... in failure caused by short heating area unit uniform tube growth, absence of serious internal deposits, absence of enormous amounts of thermally fashioned magnetic iron-ore, and violent ...level, failure ...

6

Steimann Pin Repair of Zygomatic Complex Fractures

Steimann Pin Repair of Zygomatic Complex Fractures

... Patient Selection: Only patients with type B fractures were included in this study. Patients with other midface fractures were also excluded. Patients who revealed ocu- lar symptoms and/or major depression of the orbital ...

5

Complex Lisfranc Fracture: Bidirectional Cuneiform Dislocation with Successful Closed Reduction:  A Case Report

Complex Lisfranc Fracture: Bidirectional Cuneiform Dislocation with Successful Closed Reduction: A Case Report

... Giventhis patient’s active duty status, a collaborative decision was reached atfollow-up to convert to stabilization with a Synthes X Plate design (Fig 4). During the post-operative evaluation of his films and review of ...

7

The 4Cs in Harm Reduction Programmes: A Case of Needle Syringe Exchange Programme Using Total Quality Management.

The 4Cs in Harm Reduction Programmes: A Case of Needle Syringe Exchange Programme Using Total Quality Management.

... harm reduction into direct costs and indirect costs ( Shiell and Law, 2001) , whereby direct costs include all expenditures incurred in detecting and treating the ...harm reduction into three main costs; ...

26

Vol 3, No 11 (2012)

Vol 3, No 11 (2012)

... Velicko[23] introduced the notions of θ -open subsets, θ -closed subsets and θ -closure, for the sake of studying the important class of H-closed spaces in terms of arbitrary filterbases. Dontchev and Maki ...

6

Original Article A retrospective study of open reduction and traction bed-assisted closed reduction intramedullary nailing for femoral shaft fracture

Original Article A retrospective study of open reduction and traction bed-assisted closed reduction intramedullary nailing for femoral shaft fracture

... Abstract: Objective: To compare treatment of femoral shaft fractures using traction bed assisted closed reduction (CR) or conventional open reduction (OR) for intramedullary nail fixation. Methods: ...

6

Show all 10000 documents...

Related subjects