fluid dampers

Experimental Building Demonstration Model With Viscous Fluid Dampers

Experimental Building Demonstration Model With Viscous Fluid Dampers

... HSS 1.5” x 2” x ⅛” aluminum tubing was chosen for the beams and columns, ¼” thick, bolted steel connections were chosen for the necessary “moment” connections, and clevises were chosen to simulate “pinned” connections. ...

92

Study on the Seismic Response of a Steel Building with Viscous Fluid Dampers – Chevron Configuration

Study on the Seismic Response of a Steel Building with Viscous Fluid Dampers – Chevron Configuration

... of fluid dampers to a structure does not significantly alter its natural period, but it increases damping from about 2 to 5% (internal damping) to between 20% and 40%, and sometimes even more[3] (Haskell ...

8

Limit cycle behavior of smart fluid dampers under closed loop control

Limit cycle behavior of smart fluid dampers under closed loop control

... (ER) fluid is controlled by an applied magnetic or electric field, which changes the resistance to flow of the fluid and hence controls the damping behaviour of the ...smart fluid dampers for ...

36

Supporting brace sizing in structures with added linear viscous fluid dampers: A filter design solution

Supporting brace sizing in structures with added linear viscous fluid dampers: A filter design solution

... Viscous fluid dampers have proved to be effective in suppressing unwanted vibrations in a range of engi- neering ...When dampers are fitted in a structure, a brace is typically used to attach them to ...

16

Vibration isolation with smart fluid dampers: a benchmarking study

Vibration isolation with smart fluid dampers: a benchmarking study

... Similarly, Figures 14(b) and 14(c) compare the motorway PSD plots of the passive system with the fully active and ideal semi-active modified skyhook systems respectively. Skyhook gains equal to 3kNs/m have been used in ...

38

Comparative Study on Seismic Effects of Fluid Viscous and Viscoelastic Dampers in RC Building

Comparative Study on Seismic Effects of Fluid Viscous and Viscoelastic Dampers in RC Building

... used dampers are fluid dampers, just like the shock absorbers in ...vehicles. Fluid viscous damper is composed of a piston head, a piston rod and a cylinder full of a viscous ...fluid. ...

7

Analysis and Control of Cable-Stayed Bridges Subject to Seismic Action

Analysis and Control of Cable-Stayed Bridges Subject to Seismic Action

... dynamic behaviour of a cable-stayed bridge is the connection between the deck and the towers. 6 The current trend in the design of cable-stayed bridges in earthquake-prone areas is to incorporate seismic devices in the ...

11

Study on the Analysis and Optimization of Brake Disc: A Review

Study on the Analysis and Optimization of Brake Disc: A Review

... with fluid dampers is done & manufactured by Taylor devices ...The fluid volume is reduced by the product of travel distance and piston rod ...the fluid is compressible, the reduction in ...

17

Seismic Response Study of Multistoried Reinforced Concrete Building with Fluid Viscous Dampers

Seismic Response Study of Multistoried Reinforced Concrete Building with Fluid Viscous Dampers

... The viscous fluid dampers (VFD) are the more applied tools for controlling responses of the structures. These tools are applied based on different construction technologies in order to decrease the ...

5

Evaluation of various fluid film models for use in the analysis of squeeze film dampers with a central groove

Evaluation of various fluid film models for use in the analysis of squeeze film dampers with a central groove

... nonzero fluid static stiffness, which is a characteristic of hydrostatic bearings, where deep recesses and orifices around the bearing housing are the sources of this stiffness [14, 15, ...a fluid static ...

40

Review on Viscoelastic Materials used in Viscoelastic Dampers

Review on Viscoelastic Materials used in Viscoelastic Dampers

... viscoelastic dampers were tested under static loading to failure. Half of the dampers were comprised of VE material and A36 steel, typical of most VE dampers, while the other half used wood in lieu ...

7

Review on seismic isolation and response control methods of buildings in Japan

Review on seismic isolation and response control methods of buildings in Japan

... viscoelastic dampers. The left is a 50-story building with dampers, and the right is one without ...without dampers becomes larger and larger, and eventually reaches the level where the furniture and ...

10

A Review on Seismic Analysis of Buildings using Passive Energy Dissipating Devices

A Review on Seismic Analysis of Buildings using Passive Energy Dissipating Devices

... friction dampers, velocity-dependant VE dampers and hybrid system which was a combination of friction and VE ...diagonal dampers, friction and VE chevron brace dampers, hybrid friction-VE ...

7

Innovative Designs And Technologies In Foundation Engineering And Geotechnics

Innovative Designs And Technologies In Foundation Engineering And Geotechnics

... vibration dampers (DVD) are used in practice - systems with increased damping ...dynamic dampers, it is necessary to regulate the masses of the system elements and the stiffness of the connections between ...

5

Seismic Vibration Control of Multi-Storey Asymmetric Building

Seismic Vibration Control of Multi-Storey Asymmetric Building

... (MR) dampers are semi-active systems using MR fluids to cater control forces that are fairly promising in civil engineering ...the fluid to be semisolid in state, showing plastic behavior. These ...

9

Assessment of capacity design of columns in steel moment resisting frames with viscous dampers

Assessment of capacity design of columns in steel moment resisting frames with viscous dampers

... viscous dampers may experience column plastic hinges under strong earthquakes and highlighted the need to further assess the efficiency of capacity design ...with dampers are prone to column plastic hinging ...

21

Seismic Response Evaluation of a RC Structure with Embedded Passive Dampers

Seismic Response Evaluation of a RC Structure with Embedded Passive Dampers

... when dampers are provided in the bottom storeys while there is ...when dampers are provided in all ...provide dampers in all storey thereby reducing the base ...when dampers are provided in ...

9

Design of hysteretic dampers with optimal ductility for the transverse seismic control of cable-stayed bridges

Design of hysteretic dampers with optimal ductility for the transverse seismic control of cable-stayed bridges

... In order to give a broader view of the response, Fig. 11 shows the arithmetic mean of the peak damper displacement demand (u max d,i , where i = A for the abutments and T for the towers) in the three bridges, considering ...

23

Online Full Text

Online Full Text

... some dampers were first installed between the mega-frame and substructure to ameliorate structural response control effect, the research show that the control effectiveness with additional dampers is ...

6

International Journal of Emerging Technology and Advanced Engineering

International Journal of Emerging Technology and Advanced Engineering

... three dampers of coefficient c3, c4 and c5 as shown in ...by dampers c3, c4 and c5. Springs k1 and k4; and dampers c4 and c5 are attached to rigid ...

9