• No results found

fracture fixation

RESPONSE OF METACARPAL FRACTURE FIXATION CONSTRUCTS TO PHYSIOLOGICAL LOADINGS

RESPONSE OF METACARPAL FRACTURE FIXATION CONSTRUCTS TO PHYSIOLOGICAL LOADINGS

... metacarpal fracture fixation indicates that an optimal result is not necessarily associated with the strongest ...ideal fixation would require a minimum amount of materials capable of anatomical ...

6

Outcome Analysis of Intra-Articular Scapula Fracture Fixation with Distal Radius Plate: A Multicenter Prospective Study

Outcome Analysis of Intra-Articular Scapula Fracture Fixation with Distal Radius Plate: A Multicenter Prospective Study

... of fracture encountered was type 2A according to Ideberg classification described in Table ...of fracture and associated ...for fracture fixation to know the amount of ...

8

Total hip arthroplasty for intertrochanteric fracture fixation failure

Total hip arthroplasty for intertrochanteric fracture fixation failure

... the fixation failure rate can reach ...extramedullary fixation LPFP/DHS fail- ure including 3 with internal fixation loosening, 3 with cutting of femoral head, 5 with fixation fracture ...

7

Biomechanical evaluation of fracture construct for fracture fixation of the tibia

Biomechanical evaluation of fracture construct for fracture fixation of the tibia

... fracture fixation using a plate and screws as the fixation devices and it also one of the direct method for fracture ...the fracture site by maintaining the fracture bones align ...

33

Are there too many screw holes in plates for fracture fixation?

Are there too many screw holes in plates for fracture fixation?

... a fracture of the four extremities, clavicle, hand or foot after plate osteosynthesis fixation when screws were placed in the holes of the plate adja- cent to the fracture ...the fracture ...

10

Management of comminuted patellar fracture fixation using modified cerclage wiring

Management of comminuted patellar fracture fixation using modified cerclage wiring

... band fixation using AO principles is the current standard of care and the most widely accepted method of fixation for displaced simple transverse fractures without significant comminution ...patellar ...

8

Surgical and functional outcomes of distal third tibia fracture fixation

Surgical and functional outcomes of distal third tibia fracture fixation

... whether anteromedial or anterolateral , 1999), The anteromedial approach the articular surface centrally and ment of a medial buttress plate metaphyseal portion of the fracture. ageous for exposure of the lateral ...

5

Study of Functional Outcome in Proximal Humerus Fracture Fixation using Deltoid Splitting Approach

Study of Functional Outcome in Proximal Humerus Fracture Fixation using Deltoid Splitting Approach

... benefits for fracture healing, but new surgical approaches often must be used to take full advantage of these newer methods. Splitting the anterior deltoid raphe from the acromion distally allowed direct access to ...

95

Tibia plateau fracture mapping and its influence on fracture fixation

Tibia plateau fracture mapping and its influence on fracture fixation

... only fracture pat- terns in the axial plane were considered. Fracture pat- terns in the sagittal and coronal planes also need to be taken into account when making a preoperative ...the fracture line ...

6

Finite element stress analysis of a hybrid fracture fixation plate

Finite element stress analysis of a hybrid fracture fixation plate

... the fixation plate should produce a more equitable distribution of axial compressive loads between the plate and bone while still maintaining good primary ...the fracture site, which promotes callus ...

12

A prospective study of functional and radiological outcome of neck of femur fracture treated by biplane double supported screw fixation method

A prospective study of functional and radiological outcome of neck of femur fracture treated by biplane double supported screw fixation method

... The current conventional method for femoral neck fracture fixation uses three parallel cannulated screws, but this does not always provide appropriate fixation strength. This is especially true if ...

106

A case report depicting patient’s installation on the fracture table when an ankle spanning external fixator is already in place

A case report depicting patient’s installation on the fracture table when an ankle spanning external fixator is already in place

... femur fracture and a diaphyseal or distal tibia or ankle fracture on the same limb might represent management and positioning issues in the operating ...proper fracture re- duction for proximal ...

5

Efficacy of drill free screws vs self tapping screws in zygomatico maxillary complex fractures – a randomized controlled trial

Efficacy of drill free screws vs self tapping screws in zygomatico maxillary complex fractures – a randomized controlled trial

... screw fixation time for fixing mini plates using self-tapping screws was ...screw fixation time is less in drill free screw group than self tapping screw ...complex fracture fixation with ...

6

A protocol for staged arthroplasty to salvage infected nonunion of hip fractures

A protocol for staged arthroplasty to salvage infected nonunion of hip fractures

... capsular fracture neck of the femur were treated with a staged protocol for total hip arthro- ...initial fracture fixation and presentation was 16 months (range 8–36 ...

8

Open Reduction and Internal Fixation in Pediatric Mandibular Fracture

Open Reduction and Internal Fixation in Pediatric Mandibular Fracture

... the fracture fixation ...that fracture healing is a dynamic process in which masticatory forces are slowly intensifying carried by the healing ...

117

Becoming confident about confidence intervals

Becoming confident about confidence intervals

... Acute Fracture Fixation Trial (DRAFFT) concerning the fixation of dorsally displaced distal radial fractures has been one of the most influential trials in orthopaedic surgery, 9-11 and has met with ...

5

Surgical Fixation of Subtrochanteric Fracture in Patient with Cancellous Screw Fixation for Neck of Femur Fracture: Surgical Decision-Making and Outcome

Surgical Fixation of Subtrochanteric Fracture in Patient with Cancellous Screw Fixation for Neck of Femur Fracture: Surgical Decision-Making and Outcome

... of fracture fixation complication such as revision rate, fixation failure rate, and non-union rate with intramedullary f i x at ion compared to ex tramedul lar y f i x at ion for subtrochanteric ...

6

Biologic plating of unstable distal radial fractures

Biologic plating of unstable distal radial fractures

... biologic fixation through bridge plating (BFBP) is more accurate than MIPO, since the two incisions might be larger in size than those of the conventional ...

8

A prospective study of functional outcome of displaced middle third clavicular fractures treated by plate osteosynthesis.

A prospective study of functional outcome of displaced middle third clavicular fractures treated by plate osteosynthesis.

... patients complained of hard ware irritation. Implant removed in two patients and there is no re fracture. One case had superficial infection which was treated with intravenous antibiotics. There is no difference ...

115

Delayed methicillin resistant Staphylococcus aureus induced osteomyelitis of the tibia after pin tract infection: two case reports

Delayed methicillin resistant Staphylococcus aureus induced osteomyelitis of the tibia after pin tract infection: two case reports

... external fixation is applied for a limited time to treat open fractures and periarticular fractures associ- ated with severe soft tissue ...ring fixation is applied for longer periods to address infected ...

6

Show all 5732 documents...