• No results found

Fundamental of Base Isolation

Seismic Analysis of RC Structures using Base Isolation Technique

Seismic Analysis of RC Structures using Base Isolation Technique

... of base isolation is to reduce the earthquake force produced on building ...the base isolated structure fundamental period and through damping caused by dissipation energy within bearing the ...

8

A Review Paper on Base Isolation Technique

A Review Paper on Base Isolation Technique

... The base isolation technique is a seismic design approach in which, due to the insertion of a flexible layer between the foundation and the superstructure, the fundamental frequency of the system ...

5

Natural Seismic Base Isolation of Structures Having Raft Foundations

Natural Seismic Base Isolation of Structures Having Raft Foundations

... In base isolation technique approach, the structure is essentially decoupled from earthquake ground motions by providing separate isolation devices between the base of the structure and its ...

16

Effect of Base Isolation in Multi-Storeyed RC Building

Effect of Base Isolation in Multi-Storeyed RC Building

... Earthquakes are one of nature‟s greatest hazards, throughout historic time they have caused significant loss of life and severe damage to property, especially to man-made structures. The first step in understanding ...

10

Effect of Base Isolation on Seismic Performance of RC Irregular Buildings

Effect of Base Isolation on Seismic Performance of RC Irregular Buildings

... most fundamental of these hazards is faulting, that is, the surface expression of the differential movement of blocks of the Earth’s ...loss Base isolation is used which enables a building to survive ...

8

Assesment Of Seismic Response Of Building Frame With Base Isolation

Assesment Of Seismic Response Of Building Frame With Base Isolation

... of base isolation devices in the foundation of critical structures as a mean of seismic design has attracted considerable attention in the recent years, however the shear wall frame interaction system is ...

8

Seismic Response Reduction Of Structures Using Base Isolation

Seismic Response Reduction Of Structures Using Base Isolation

... adoptive.The base isolation system is one such passive control system that decouples the structure from the horizontal components of the ground motion by imposing flexible isolation elements with low ...

8

Sustainability of Structure Using Base Isolation Techniques for Seismic Protection

Sustainability of Structure Using Base Isolation Techniques for Seismic Protection

... utilize isolation system with added damping was the Toetoe viaduct in North Island of New ...The Isolation system consisted laminated steel and rubber bearings incorporating a specially formulated high ...

14

Base Isolation

Base Isolation

... Abstract: Base isolation is one of a most popular means of protecting a structure against earthquake ...as base isolation. A base isolated structure is supported by the series of ...

5

Seismic Base Isolation of RC Frame Structures with and Without Infill

Seismic Base Isolation of RC Frame Structures with and Without Infill

... earthquake. Base isolation is one such type of method used to prevent the damage to the ...behind base isolation is to separate substructure from ...The base shear and the storey drifts ...

10

Base Isolation Systems – A State of the Art Review According to Their Mechanism

Base Isolation Systems – A State of the Art Review According to Their Mechanism

... As shown in Fig. 3, the horizontal stiffness of the LDRB isolator is much less than its vertical stiffness, which is necessary for the isolation. The disadvantage of this isolator is that it dissipates little ...

25

A Review Paper on Comparative Study of Fixed Base, Base Isolation & Damper System in RC Building

A Review Paper on Comparative Study of Fixed Base, Base Isolation & Damper System in RC Building

... with base, with base ...basement. Base isolation system is the passive control device which decouples the super structure from substructure resting ground motion by insinuating structural ...

5

A Review of Behaviour of Building under Earthquake with or without Base Isolation

A Review of Behaviour of Building under Earthquake with or without Base Isolation

... Seismic Base-isolation of building is an innovative technique used in recent years, for reducing seismic energy transmitted to buildings, in highly seismic prone ...the base-isolation system ...

5

Base Isolation of Mass Irregular RC Multi Storey Building

Base Isolation of Mass Irregular RC Multi Storey Building

... seismic isolation is to protect the structure from the damaging effects of an earthquake by introducing a flexible support isolating the building from the shaking ...Seismic isolation consists of ...

5

Evaluation of G+ 10 Structure for Seismic Performance Under Base Isolation

Evaluation of G+ 10 Structure for Seismic Performance Under Base Isolation

... hazards base isolation is one of the best technique against the ...“base isolation”. Base isolation consist the various system which are to be installed under the superstructure ...

9

Seismic Performance of Low-Ductility Precast Wall Structure with Base Isolation

Seismic Performance of Low-Ductility Precast Wall Structure with Base Isolation

... seismic base isolation although the founding of such technology can be traced back to few decades ...seismic base isolation does not hundred percent absorb and dissipate energy from ground ...

10

Time History Analysis of Multi Story Building with and without Base Isolation

Time History Analysis of Multi Story Building with and without Base Isolation

... at base level considerably increases the time period of the structure, which means it reduces the possibility of resonance of the structure giving rise to better seismic performance of the ...of base the ...

5

Study on 3-Dimensional Base-Isolation System applying to New Type Power Plant Reactor: Part 2 (Hydraulic 3-Dimensional Base-Isolation System)

Study on 3-Dimensional Base-Isolation System applying to New Type Power Plant Reactor: Part 2 (Hydraulic 3-Dimensional Base-Isolation System)

... The performances and the applicability have already been evaluated by the technical feasibility tests and performance tests for each system. In this study, it was evaluated that the performance of the 3D base ...

12

Semi active damping control for vibration isolation of base disturbances

Semi active damping control for vibration isolation of base disturbances

... When performing numerical simulations with semi-active dampers the so-called chatter problem occurs under certain dynamic conditions. To observe the onset and persistence of chatter in a on-off skyhook semi-active ...

194

Study   On 3-Dimensional Base Isolation System Applying to New Type Power Plant   Reactor (Hydraulic 3-Dimensional Base Isolation System: No.1) (K148)

Study On 3-Dimensional Base Isolation System Applying to New Type Power Plant Reactor (Hydraulic 3-Dimensional Base Isolation System: No.1) (K148)

... In this paper, we propose a new three-dimensional base isolation system that should solve the foregoing problem. The system is constituted of a set of hydraulic load-carrying cylinders connected to ...

8

Show all 9358 documents...