• No results found

grid protection

Assessment On The Impact Of Distributed Generation (Dg) Penetration On Grid Protection System

Assessment On The Impact Of Distributed Generation (Dg) Penetration On Grid Protection System

... Yadav and Srivastava (2014) suggested that Distributed Generation (DG) is the generation of electricity from small scale of generation and is located closer to the user, or customer which is commonly at the distribution ...

24

Design and Testing of Three Earthing Systems for Micro Grid Protection during the Islanding Mode

Design and Testing of Three Earthing Systems for Micro Grid Protection during the Islanding Mode

... A MG consists of a cluster of micro sources, energy storage systems (e.g. flywheel, battery, ultra capacitor, …) and loads, operating as a single controllable system. The voltage level of the MG is 400 Volt or less. The ...

11

Measurement and analysis of PMU reporting latency for smart grid protection and control applications

Measurement and analysis of PMU reporting latency for smart grid protection and control applications

... system protection and control applications require faster-responding measurements and more accurate knowledge of the actual latency of the measurement and communications ...PMU-based protection and control ...

10

Assessment On The Impact Of Distributed Generation (Renewable Energy) Penetration To The National Grid Protection System Performance Using Eracs Software

Assessment On The Impact Of Distributed Generation (Renewable Energy) Penetration To The National Grid Protection System Performance Using Eracs Software

... the protection system is also straightforward as the fault current can only flow in one ...present protection system. This is because the present protection system do not cater the problem cause by ...

24

Comparison the Performances of Three Earthing Systems for Micro Grid Protection during the Grid Connected Mode

Comparison the Performances of Three Earthing Systems for Micro Grid Protection during the Grid Connected Mode

... Figure 8 shows a single line diagram of the studied MG. The studied MG is connected to the main grid through three phase 400 kVA, 20/0.4 kV ∆/Ү transformer. MG consists of 7 buses. Flywheel (storage device) with ...

10

Study of Micro Grid Safety & Protection Strategies with Control System Infrastructures

Study of Micro Grid Safety & Protection Strategies with Control System Infrastructures

... micro grid in both the grid-connected and the islanded mode of operation against all different types of ...micro grid protection and safety concept with central control and monitoring unit ...

9

Safety Assured Reliable Microgrid

Safety Assured Reliable Microgrid

... adaptive/intelligent protection system for micro grid is described ...advanced protection system can potentially solve the problems identified ...The protection scheme must ensure safe ...

10

An Adaptive Limited Wide Area Differential Protection for Power Grid with Micro-Sources

An Adaptive Limited Wide Area Differential Protection for Power Grid with Micro-Sources

... relaying protection principle, system structure, and wide area ...relaying protection. Recently, wide area differential protection (WADP) and wide area directional comparison protection ...

10

A Comprehensive Review on LVRT Capability for DFIG System

A Comprehensive Review on LVRT Capability for DFIG System

... the grid-side inverter, the main reason of the LVRT control schemes was to insert reactive power into the grid that depends on the grid-code ...

8

Adaptive protection architecture for the smart grid

Adaptive protection architecture for the smart grid

... wide protection and primary system performance in ...evaluation, protection action and protection ...the protection action ...where protection schemes can act against the operator [14]. ...

8

Protection Strategies against Cascading Failure for Power Systems of Ring Network

Protection Strategies against Cascading Failure for Power Systems of Ring Network

... Power failures are more often caused by unstable voltage levels and frequencies [2]. The instability of fre- quency from generated voltage will cause asynchronization of generators, greatly reducing power generation and ...

12

Analysis of Attenuation Effect of Grid-Like Spatial Shields Used in Lightning Protection of Buildings

Analysis of Attenuation Effect of Grid-Like Spatial Shields Used in Lightning Protection of Buildings

... lightning protection of buildings to attenuate the effects of radiated electromagnetic field produced by lightning strikes and are primarily used for protection of building zones that contain particularly ...

13

Course Catalogue SOLVINA OFFERS A RANGE OF HIGHLY REQUESTED PROFESSIONAL COURSES PRESENTED BY TOP LEVEL SPEAKERS AT WORLD-WIDE LOCATIONS

Course Catalogue SOLVINA OFFERS A RANGE OF HIGHLY REQUESTED PROFESSIONAL COURSES PRESENTED BY TOP LEVEL SPEAKERS AT WORLD-WIDE LOCATIONS

... SPEAKER’S PROFILE Charles Henville is a specialist in electric power system protection. After thirty-year career with BC Hydro in Canada, he retired in 2005 from the position of principal engineer. He now runs his ...

13

1.
													An adaptive directional over – current protection and earth fault protection of distributed systems

1. An adaptive directional over – current protection and earth fault protection of distributed systems

... the grid up-stream to improve the reliability of power ...transmission grid. Hence the overcurrent protection system designed for the grid connected condition results in longer fault clearing ...

8

Frequency Control Scheme Using Integrated Grid Inverter for Wind Mill Applications

Frequency Control Scheme Using Integrated Grid Inverter for Wind Mill Applications

... Under normal operating condition there is no change in the grid frequency. While there is an increase in the load inductance, then a lagging power factor occurs which cause a change in grid frequency. The ...

5

Voltage and stability analysis of distribution networks with non-conventional energy sources

Voltage and stability analysis of distribution networks with non-conventional energy sources

... Fielding, 'Protection against loss of utility grid supply for a dispersed storage and generation unit', IEEE Transactions on Power Delivery,. Vol 8, Iss 3, pp 948-54, Julyl993[r] ...

209

Simulation of Power Flow and Protection of a Limited Bus Grid System with Injected Solar Power

Simulation of Power Flow and Protection of a Limited Bus Grid System with Injected Solar Power

... A small 50 Hz grid system of ten buses with overcurrent protection system is constructed in ETAP as in Figure 1. There are three buses at extra high voltage level devel- oped in ring main system. Four ...

11

Cyber-physical security of Wide-Area Monitoring, Protection and Control in a smart grid environment

Cyber-physical security of Wide-Area Monitoring, Protection and Control in a smart grid environment

... Special Protection Schemes (Remedial Action Schemes) respectively and their im- ...the protection relays and substation commu- nications happening in different locations, staggered in ...

9

Threat Assessment for Multistage Cyber Attacks in Smart Grid Communication Networks

Threat Assessment for Multistage Cyber Attacks in Smart Grid Communication Networks

... electric grid must be able to give out information on the expected time to recovery and delays (if any) to the start of the ...smart grid about the potential consequence of the cyber ...

198

Grid Computing Models for Discovering the Resources

Grid Computing Models for Discovering the Resources

... the grid causes the system to use efficient routings algorithms for queries, to enhance the scalability of the grid ...in grid will cause loss of queries in the ...

5

Show all 10000 documents...

Related subjects