• No results found

harmonic distortion and reactive power compensation

Harmonic Distortion and Reactive Power Compensation in Single Phase Power Systems using Orthogonal Transformation Strategy

Harmonic Distortion and Reactive Power Compensation in Single Phase Power Systems using Orthogonal Transformation Strategy

... Active power Filter Ratings The frequency of switching of the IGBT devices, constituting the active power filter, is inversely related to the hysteresis controller ...active power filter isolating ...

11

Harmonic Analysis and Its Mitigation Technique In Industrial Environment

Harmonic Analysis and Its Mitigation Technique In Industrial Environment

... of harmonic filters would help in the reduction of ...a harmonic filter comprises an inductor and a capacitor. Harmonic filters are mainly classified into Passive harmonic filters, Active ...

6

Simulation Modeling and Analysis of Reactive Power Compensation using Thyristor controlled LC Compensator in smart grid

Simulation Modeling and Analysis of Reactive Power Compensation using Thyristor controlled LC Compensator in smart grid

... A large number of nonlinear loads are used in applications at various power levels. Examples of nonlinear loads include variable speed drives, lighting systems, switch mode power supplies and many more ...

10

Reactive Power Compensation and Limiting Harmonic Current using Shunt Active Power Filter

Reactive Power Compensation and Limiting Harmonic Current using Shunt Active Power Filter

... the harmonic current ...utility power source current after the harmonic compensation has some harmonics components but these can be ignored as per the IEEE ...(total harmonic ...

5

Power Quality Improvement using Shunt Hybrid Power Filter (SHPF) and Thyristor Controlled Reactor (TCR)

Power Quality Improvement using Shunt Hybrid Power Filter (SHPF) and Thyristor Controlled Reactor (TCR)

... the reactive power ...with harmonic and reactive power compensation and analysis through the total harmonic distortion (THD) of the source voltage and the source ...

10

Asingle Phase Active Device for Power QualityImprovement of Electric Field Transportation

Asingle Phase Active Device for Power QualityImprovement of Electric Field Transportation

... days, power quality has been given attention due to the intensive use of power electronic equipments in all types of industries such as steel, paper, textile industries and so ...These power ...

10

Index Terms: Active power filter (APF), cascaded multilevel inverter, close-loop control, feed forward of fundamental load current I INTRODUCTION

Index Terms: Active power filter (APF), cascaded multilevel inverter, close-loop control, feed forward of fundamental load current I INTRODUCTION

... current compensation by means of active power filter (APF) is a well-known effective solution for the reduction of current distortion and for power quality improvement in electrical ...the ...

7

Modelling of Photo Voltaic Array with Active Power Filter

Modelling of Photo Voltaic Array with Active Power Filter

... maximum power point, high efficiency, control power injected into the grid, high power factor and low total harmonic distortion of the currents injected into the grid ...to power ...

8

Design and Simulation of Shunt Active Power Filter for Harmonic Compensation Using Fuzzy Logic Controller

Design and Simulation of Shunt Active Power Filter for Harmonic Compensation Using Fuzzy Logic Controller

... active power filter used to compensate for harmonic distortion in three-phase four-wire ...the power transmission capacity and extend the transient ...the power factor, compensate the ...

7

Enhancement of Power Quality using Fuzzy Logic based UPQC

Enhancement of Power Quality using Fuzzy Logic based UPQC

... continuous power supply is not the need of ...of power is a major issue these days. Power quality engineers are concerned about keeping the supply purely sinusoidal and at acceptable frequency but ...

7

Improved Performance of FOPI Based Wind Energy Conversion System Using Multilevel Inverter

Improved Performance of FOPI Based Wind Energy Conversion System Using Multilevel Inverter

... Another power change framework is investigated in this paper pointing wind turbines evaluated at the megawatt level. The proposed setup comprises of a medium-voltage, lasting magnet synchronous generator ...

8

Improvement of Power Quality by Reduction of Harmonics

Improvement of Power Quality by Reduction of Harmonics

... total harmonic distortion value will be very much reduced on connecting this ...total harmonic distortion is shown in Fig 8 and ...of distortion of wave form after connecting the ...

7

Reactive Power Compensation Capability and Active Power Transfer of PMSG Based Variable Speed WECS

Reactive Power Compensation Capability and Active Power Transfer of PMSG Based Variable Speed WECS

... on power quality of the system where as weak grids can accept limited number of wind turbines, or the grid has to be ...between power co-efficient (C p )and wind power captured by the wind ...

9

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES MANAGEMENT STUDY OF TOTAL HARMONIC DISTORTION IN THYRISTOR CONTROLLED REACTOR EMPLOYED IN STATIC VOLTAGE COMPENSATOR Mukti Verma and Satyadharma Bharti

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES MANAGEMENT STUDY OF TOTAL HARMONIC DISTORTION IN THYRISTOR CONTROLLED REACTOR EMPLOYED IN STATIC VOLTAGE COMPENSATOR Mukti Verma and Satyadharma Bharti

... of harmonic distortion, DC components, real and reactive power and other variables is obtained in the firing angle range of thyristor between 85 0 to 120 0 ...of distortion we should ...

9

SEVEN LEVEL CONTROL OF SHUNT ACTIVE POWER FILTER FOR POWER QUALITY ENHANCEMENT

SEVEN LEVEL CONTROL OF SHUNT ACTIVE POWER FILTER FOR POWER QUALITY ENHANCEMENT

... Active Power Filter (SAPF) is one of the controllers to enhance power quality ...compensate reactive power, improve the power factor and to suppress the total harmonic ...

10

Exploring the Impact of Work Life Balance on the Employee and Organisational Growth

Exploring the Impact of Work Life Balance on the Employee and Organisational Growth

... total harmonic distortion(THD) in the load voltage waveform, current Waveform, Active power, Reactive power are compare for the same DC input voltage and same load using MATLAB ...total ...

5

Improvement of Power Quality by Reduction of Harmonics

Improvement of Power Quality by Reduction of Harmonics

... Increase of harmonic distortion is becoming an important factor in commercial and industrial side now-a-days. The reduction of harmonics in this side is becoming mandatory for Engineers in recent surveys. ...

8

A Review on Selection and Usage of Modern Active Power Filter

A Review on Selection and Usage of Modern Active Power Filter

... active power filter for particular application for compensation of parameters as listed in Table ...appropriate harmonic reduction method for a given application on an easier ...

6

CONTROLLING TECHNIQUES OF SHUNT ACTIVE POWER FILTER FOR POWER QUALITY IMPROVEMENT

CONTROLLING TECHNIQUES OF SHUNT ACTIVE POWER FILTER FOR POWER QUALITY IMPROVEMENT

... In this paper detail discussion about the main working principle of shunt active power filter in section II. Here the mathematical analysis of controlling methods of SAPF explains in section III. The simulation ...

10

Comparison of Shunt Active Power Filter with Different Control Algorithms Using Particle Swarm Optimization Technique

Comparison of Shunt Active Power Filter with Different Control Algorithms Using Particle Swarm Optimization Technique

... Instantaneous symmetrical component theory is used for both current and voltage compensation.The Technique was introduced by “Fortescue”. It is applied to resolve an unbalanced Three-phase system of voltages and currents ...

12

Show all 10000 documents...

Related subjects