• No results found

High gradient magnetic separation(HGMS)

Optimized high gradient magnetic separation for isolation of Plasmodium infected red blood cells

Optimized high gradient magnetic separation for isolation of Plasmodium infected red blood cells

... principle, high gradient magnetic separation (HGMS) offers a way to concentrate or deplete malaria irbc from suspensions, relying solely on their intrinsic magnetic ...particle, ...

9

Study on Optimizing High Gradient Magnetic Separation—Part 1: Improvement of Magnetic Particle Retention Based  on CFD Simulations

Study on Optimizing High Gradient Magnetic Separation—Part 1: Improvement of Magnetic Particle Retention Based on CFD Simulations

... a high-gradient magnetic separation laboratory plant which consists of a magnetic separator, a pump and a flow ...The high-gradient magnetic separator type HGF10 ...

14

Study on Optimizing High Gradient Magnetic Separation—Part 2: Experimental Evaluation of the Performance of a  New Designed Magnetic Filter

Study on Optimizing High Gradient Magnetic Separation—Part 2: Experimental Evaluation of the Performance of a New Designed Magnetic Filter

... a high-gradient magnetic separator, a filter matrix is inserted in the filter chamber to build a highly inhomogeneous magnetic field ...improving high-gradient magnetic ...

15

Parameterization of high magnetic field gradient fractionation columns for applications with Plasmodium falciparum infected human erythrocytes

Parameterization of high magnetic field gradient fractionation columns for applications with Plasmodium falciparum infected human erythrocytes

... of magnetic fractionation of erythrocytes infected with Plasmodium falciparum conducted to ...of separation column and specific parasite strains, the present approach can be used to guide quanti- tation of ...

9

Upgrading Feldspar by WHIMS and Flotation Techniques

Upgrading Feldspar by WHIMS and Flotation Techniques

... Thai feldspar reserves are founded in many provinces such as Tak, Uthaithani, Ratchaburi, Nakhonsithammarat, Chiangmai, Lamphun, Sukhothai, and Kanchanaburi. Although most of the reserves are saleable, either directly or ...

10

Applications of Thermomagnetic Convection in Thermal Management of Electronic Systems.

Applications of Thermomagnetic Convection in Thermal Management of Electronic Systems.

... sensitive magnetic fluid (Mn-Zn ferrite based) operating under steady-state laminar flow conditions in a partially heated thermomagnetic circulation loop under the influence of an external magnetic field ...

110

Preconcentration Feasibility of Gravity and Magnetic Techniques for Banded Hematite Jasper

Preconcentration Feasibility of Gravity and Magnetic Techniques for Banded Hematite Jasper

... The iron recovery achieved through MDS shown in Table 2 varies from 59.3 % at -10+0.5mm to 68.5% at -3+0.5mm size fraction. Similarly the concentrate grade varies from 52.37% Fe at -10+0.5mm s ize to 57.4% Fe at -3+0.5mm ...

8

Rotating magnetic field separation of minerals

Rotating magnetic field separation of minerals

... The rotation index The relationship between particle magnetic moment lifting fields and rotation indices The relationship between rotation indices and anisotropy constants The effect of [r] ...

296

Measurements of Micro-Turbulence in High Beta and High Density Regimes of LHD and Comparison with Resistive G-Mode Scaling

Measurements of Micro-Turbulence in High Beta and High Density Regimes of LHD and Comparison with Resistive G-Mode Scaling

... to high performance plasma operation, including operation at low field (B ∼ ...T), high volume average beta (up to 5%) [1], as well as at high field (B > 2 T), high central beta with ...

10

Upregulation of CD47 in Regulatory T Cells in Atopic Dermatitis

Upregulation of CD47 in Regulatory T Cells in Atopic Dermatitis

... LC gradient began with 5% B for 5 min and was increased to 15% B over 5 min, to 50% B over 100 min, and then to 95% B over 5 min, at which point it remained at 95% B for 5 min and then decreased to 5% B for ...

11

Sanchez Antequera, Yolanda
  

(2010):


	Magselectofection: A novel integrated technology of magnetic separation and genetic modification of target cells.


Dissertation, LMU München: Fakultät für Chemie und Pharmazie

Sanchez Antequera, Yolanda (2010): Magselectofection: A novel integrated technology of magnetic separation and genetic modification of target cells. Dissertation, LMU München: Fakultät für Chemie und Pharmazie

... of magnetic particle and viral vector were found by serial titrations of tranducing units of lentivirus with magnetic particles followed by magnetic sedimentation of the complexes and determination ...

145

Mathematical Model of Blood Flow in Small Blood Vessel in the Presence of Magnetic Field

Mathematical Model of Blood Flow in Small Blood Vessel in the Presence of Magnetic Field

... of magnetic field on blood flow has been analyzed theoretically by treating blood as an electrically conductive fluid ...a magnetic fluid, it may be possible to control blood pre- ssure and its flow ...

6

Experimental Study of Hall Effect on a Formation Process of an FRC by Counter-Helicity Spheromak Merging in TS-4

Experimental Study of Hall Effect on a Formation Process of an FRC by Counter-Helicity Spheromak Merging in TS-4

... its high-beta. High-beta mag- netic confinement is important for economical fusion re- actor, and the simply-connected structure of an FRC en- ables to make a fusion reactor ...need high-voltage fast ...

5

Analysis of the Magnetic Field Homogeneity for an Equilateral Triangular Helmholtz Coil

Analysis of the Magnetic Field Homogeneity for an Equilateral Triangular Helmholtz Coil

... lower magnetic field homogeneity than the CH coils for the parameters side length (2 a , √ 3 a ) and radius ( a ) ...(ELF) magnetic fields and its choice basically depends on the applications and constraints ...

9

Design of high magnetic field gradient sources for controlling magnetically induced flow of ferrofluids in microfluidic systems

Design of high magnetic field gradient sources for controlling magnetically induced flow of ferrofluids in microfluidic systems

... The use of miniature electromagnets for ferrofluid-actuated liquid dispensing into microfluidic channels has been investigated by numerical simulations using the finite element method and measurements of fluid ...

6

Mathematical Modelling on blood flow through Stenosed artery under the influence of Magnetic field

Mathematical Modelling on blood flow through Stenosed artery under the influence of Magnetic field

... Consider an axially symmetric, laminar and steady flow of blood through a rigid circular artery with a mild stenosis under the influence of an externally applied uniform magnetic field. This model is developed ...

7

Scale-up of affinity separation based on magnetic support particles

Scale-up of affinity separation based on magnetic support particles

... the magnetic adsorbents were recovered in a batch ...of magnetic particles without dismantling the canister was not possible because of physical entrapment caused by the natural filtration effect of the ...

212

Effect of combined density gradient centrifugation on X- and Y- sperm separation and chromatin integrity

Effect of combined density gradient centrifugation on X- and Y- sperm separation and chromatin integrity

... discontinuous gradient techniques such as albumin and PureSperm are used routinely to separate and purify human motile, morphologically normal spermatozoa, although possible chromatin anomalies cannot be directly ...

6

Amine Functionalized Kit-6 Mesoporous Magnetite Nanocomposite as an Efficient Adsorbent for Removal of Ponceau 4R Dye from Aqueous Solutions

Amine Functionalized Kit-6 Mesoporous Magnetite Nanocomposite as an Efficient Adsorbent for Removal of Ponceau 4R Dye from Aqueous Solutions

... of no salt addition was performed for the kinetic and isotherm studies. According to the results, the presence of high ionic content in the sample reduces removal efficiency. Effect of pH on the removal efficiency ...

12

Surfactant Assisted Dispersion of Single-Walled Carbon Nanotubes in Polyvinylpyrrolidone Solutions

Surfactant Assisted Dispersion of Single-Walled Carbon Nanotubes in Polyvinylpyrrolidone Solutions

... Biercuk et al. used 1% wt/v of nanotubes as filler for epoxy resin composites and successfully doubled the thermal conductivity compared to their sample without the nanotubes. Comparatively, a quality control of carbon ...

128

Show all 10000 documents...

Related subjects