high interrupting capacity circuit breaker

Top PDF high interrupting capacity circuit breaker:

SUGGESTED SPECIFICATION For Medium Voltage Automatic Transfer Switches

SUGGESTED SPECIFICATION For Medium Voltage Automatic Transfer Switches

2. Entrance to the stationary primary disconnecting contacts shall be automatically covered by metal shutters when the circuit breaker is withdrawn from the connected position to the test or disconnected position or removed from the circuit breaker compartment. Extend a ground bus into the circuit breaker compartment to automatically ground the breaker frame with high-current spring type grounding contacts located on the breaker chassis when in the test and connected positions. Guide rails for positioning the circuit breaker and all other necessary hardware are to be an integral part of the circuit breaker compartment. Blocking devices shall interlock breaker frame sizes to prevent installation of a lower ampere rating or interrupting capacity element into a compartment designed for one of a higher rating. It shall be possible with indoor switchgear to install a circuit breaker into a bottom compartment without use of a transport truck or lift device.
Show more

15 Read more

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

Manufacturers have also developed nonfused current- limiting circuit breakers, designed to protect downstream equipment or to obtain a higher interrupting capacity rating for the circuit breaker. Again, a short-time delay would not be appropriate in these applications because the circuit breaker trips in the first half-cycle for a high-magnitude fault. Smaller-frame current-limiting MCCBs can be series rated to protect downstream equipment, but in general circuit breakers above 400-ampere frame size cannot be series rated. Larger-frame current-limiting MCCBs, ICCBs, and LVPCBs are usually applied for their high interrupting capacity. The current-limiting capabilities may limit arc flash hazards and do allow space-saving applications, but selective coordination typically is sacrificed due to the instantaneous tripping.
Show more

6 Read more

Alternatives to SF6 in HV circuit breaker insulation

Alternatives to SF6 in HV circuit breaker insulation

One of the earliest methods for making or breaking current was a plain knife switch in air, perhaps best envisioned to that of the switch that turned Edison ear power systems on. This simply device was limited in terms of capacity where early experimentation revealed high voltages could re-spark across the open air gap and high currents would maintain the arc across the open air gap. More sophisticated interpretations of the knife switch are still used in industry today however, manually operated air break switches (ABS) are still commonly used for electrical current interruption at lightly loaded rural substations or feeders. ABS’s are also still the isolation mechanism of choice for no-load breaking visual isolation in most high voltage switch yards. It is known now that interrupting the resulting self sustaining electrical arc in air is directly related to the natural deionisation process in the air surrounding the arc. Cooling the arc increases the deionisation which in turn increases the arc resistance. Increased arc resistance limits the arc sustaining electrical current flow and increases the success rate of arc interruption.
Show more

154 Read more

Systemic risk in the US: interconnectedness as a circuit breaker

Systemic risk in the US: interconnectedness as a circuit breaker

Third, a plot of the average systemic risk against its variability (for each firm) effectively separates three groups of financial firms and high- lights two areas of considerable regulatory interest. The first consists of firms which are consistently ranked amongst the most risky in the economy and rarely move outside of this range – including JP Mor- gan, Wells Fargo, Bank of America and Lehman (before its demise). The second category of interest is firms with an average systemic rank- ing somewhere in the middle of our sample but with high variabil- ity, including AIG, KeyCorp, and Regions Financial Corp in our sam- ple. These are firms which on average do not seem to be a source of concern, but which have the capacity to quickly become a prob- lem. Financial firms are predominantly found in these two groups, providing strong evidence of the important role that macro pruden- tial regulation may play in ensuring financial and economic stability. The final group is firms which are consistently display little systemic risk.
Show more

11 Read more

Semiconductor devices in solid state/hybrid circuit breakers: current status and future trends

Semiconductor devices in solid state/hybrid circuit breakers: current status and future trends

In recent times, power semiconductor devices have been applied expansively in circuit breakers as they are practically controlled switches [2]. The object called ‘solid-state circuit breaker (SSCB)’, is the CB with pure semiconductor devices [3,4]. With silicon-based power devices, SSCBs offer tripping speeds of up to hundreds of microseconds. Furthermore, as there is no mechanical components or parts, neither contact erosion, electric arc, nor strong mechanical shake exists. On the other hand, SSCBs present several disadvantages: (a) the unignorable on-state resistance means significant power loss, which could cause critical heat and lower system efficiency; (b) semiconductors are sensitive to transit over-voltage and heat-causing over-currents, which makes them a natural weakness of the whole electric system and needs more self-protection technology; (c) the costs and physical volume of semiconductor devices is no doubt a limitation for further development; (d) bidirectional semiconductor devices [5,6] are needed for bidirectional applications (e.g., AC or power regeneration fields), thus doubling the number of devices, redoubling the costs and complexity of control, and reducing reliability. As a result, pure SSCBs are now used in low-power low-voltage (e.g., 24 V) systems, where switching speed must be guaranteed, and power loss is not a priority. In future, by applying next-generation wide bandgap devices e.g., silicon carbide (SiC) or gallium nitride (GaN), the performance of SSCBs may be improved because of lower power loss, higher junction temperature, better avalanche breakdown capability and so on.
Show more

25 Read more

High Performance Circuit Breaker S800HV-K for applications up to 1000 V AC

High Performance Circuit Breaker S800HV-K for applications up to 1000 V AC

Group protection: One single S803HV-SCL-SR can protect several mounted downstream S803HV-K. This case is cost effective as all of the used S803HV-K will have a short-circuit breaking capacity of 15 kA. In case of a failure, only the defective branch will open. The other branches with S803HV-K will remain operative.

8 Read more

Circuit breaker prognostics using SF6 data

Circuit breaker prognostics using SF6 data

Type II systems give a “stressor-based prediction” [1], which combine the average component lifetime of a type I model with information about the environmental conditions experienced by a given asset. A type II system takes account of the different ways an asset can be used. For example, some circuit breakers are exercised frequently for switching operations, whereas others are expected to operate only to clear faults, and may remain unexercised for years at a time. These different environmental factors can exert different stresses on the breaker - one experiences regular, low level wear while the other experiences infrequent, high levels of wear - and consequently, one particular model of breaker could fail at different rates depending on whether it is used primarily for switching or fault clearance.
Show more

6 Read more

Molded Case Circuit Breakers. Section 6. BuyLog Catalog 6-1

Molded Case Circuit Breakers. Section 6. BuyLog Catalog 6-1

These breakers are available with either noninterchangeable trip (designated Type TJJ) or interchangeable trip (designated Type TJK and THJK). Type TJJ product numbers include frame, trip, Cu/Al line, and load lugs factory assembled. If line lugs are not required on the breaker, eliminate “WL” from product number, and subtract price of line lugs from price of complete breaker. TJK breakers are available in two frames, 400 ampere frame (125 to 400 amperes) and 600 ampere frame (250 to 600 amperes). Trip units are not interchangeable between frames. “Complete Circuit Breaker” price includes frame, trip unit, Cu/Al line, and load lugs. Unit will be shipped unassembled unless order specifies “must be factory assembled.” If line lugs are not required, eliminate “WL” from product number and subtract price of line lugs from price of complete breaker.
Show more

106 Read more

Accurate, Re-Settable Electronic Circuit Breaker

Accurate, Re-Settable Electronic Circuit Breaker

HV320 is an ideal alternative to thermal and manual circuit breakers in DC input applications. It has wide variety of uses in the automotive industry, such as PCB trace / device protection and DC motors and solenoid actuator current limit protection. These devices are typically used in windows and seat adjustment operations as well as automatic trunk opening mechanisms. Since these devices are operated manually, they can remain energized by the operator even after the mechanical lever has reached its end of travel. In this case, back EMF that normally opposes the supply voltage will drop to zero and a large current surge can begin to flow. HV320 can accurately be programmed to trip the current. In industrial applications, HV320 can offer broad solutions in DC solenoid-operated valves, DC motors and other electromagnetic loads.
Show more

9 Read more

Multipurpose Lightning Auto Reset For Houses

Multipurpose Lightning Auto Reset For Houses

Low-voltage circuit breakers also made for direct-current (DC) applications. Example; DC supplied for subway lines. A direct current needs a special breaker because the arc does not have a natural tendency to go out on each half cycle as for alternating current. A direct current circuit breaker will blow-out coils which it generates a magnetic field that rapidly stretches the arc when interrupting direct current. Small circuit breakers are either installed directly in equipment, or are arranged in a breaker panel.
Show more

24 Read more

INDUSTRIAL SPARE PARTS SUPPLIER

INDUSTRIAL SPARE PARTS SUPPLIER

Single-pole circuit breaker: it usually operates with two tripping coils and one closing coil. Each bay contains 3 single-pole breakers, one per phase. When a single-phase fault occurs, a single-pole breaker opens the affected phase separately, without needing to open all the phases and enabling a single-phase reclosing.

24 Read more

Disconnect Switch and Circuit Breaker Mechanism Specifications

Disconnect Switch and Circuit Breaker Mechanism Specifications

Bulletin 1494G, 1494GX, 1494GY Enclosed Disconnect Safety Switches Type 3R/4/12 (Enclosure Code “F”) Painted Metal Enclosures.. Approximate dimensions are shown in inches..[r]

26 Read more

Terrestrial laser scanning for 3D zone substation modelling and safety clearances

Terrestrial laser scanning for 3D zone substation modelling and safety clearances

Nevertire Zone Substation was scanned on site with a high definition laser scanner and a 3D model produced in the form of a point cloud file. This point cloud file was then used to produce a 3D wireframe model which can be used for design purposes. The point cloud file and wireframe model were checked for accuracy against on site measurements and both models produced extremely accurate results. These results were then compared directly with conventional survey measurements (already completed at Nevertire Zone Substation) to highlight the differing levels of accuracy available in the different data capture techniques.
Show more

173 Read more

DC Microgrids: Architectures, Control and Economic Analysis.

DC Microgrids: Architectures, Control and Economic Analysis.

In the worst case, when the fault happens very close to the converter in fact at the converter DC link, R is small compared to L and the time constant is high consequently. This means that a high current is passing through the anti-parallel diodes for a long time, which causes serious damage to the converter. Therefore, the control algorithm itself would not be able to protect the converter station during the worst situation. The performance of the control algorithm when the DC fault occurs 200m away from the converter and when it happens very close to the converter station are shown in Figure 6.23. It can be seen that when the fault happens far enough from the converter, the time constant, T = R L , is small and the fault current decreases fast enough before damaging the converter. However, when the fault happens at the converter DC link, the time constant is large and the high fault current flows through the anti-parallel diodes for a long time, which will result in a serious converter damage. As it was mentioned and shown in the simulations, the control algorithm itself cannot protect the converter in the worst case scenario. In the next section, a novel method which employs a Hybrid FCL discussed earlier with the mentioned control algorithm is proposed to solve the discussed issue. This method works based on adding an additional resistance whenever the fault is close to the converter. The resistance should be added to the line whenever it is needed and should have no impact on the system in the normal operation. To overcome the discussed challenges, the hybrid FCL discussed in Section 6.4.5 will be used.
Show more

226 Read more

Multiprocessor Based Architecture for Controlled Switching of Circuit Breaker

Multiprocessor Based Architecture for Controlled Switching of Circuit Breaker

Energizing shunt reactors shunt capacitors and power transformers may cause high over-voltage, under-voltage or high in-rush currents. De-energizing capacitive loads, harmonic filters and shunt reactors result in restrikes. Re- ignition may occur, resulting in steep voltage surges. The magnitude of transient depends upon the instant on the voltage waveform where opening or closing of breaker contacts occur. In an uncontrolled situation, sooner or later switching is bound to occur at the worst possible points-on- wave. Conventional methods used to limit the magnitude of these switching transients like Pre-insertion resistors, Damping Reactors, Arrestors or upgrading the insulation are inefficient, unreliable or expensive and do not address the root problem.
Show more

7 Read more

A Fast Acting DC Solid State Circuit Breaker.

A Fast Acting DC Solid State Circuit Breaker.

As a part of ongoing research on MVDC, a 400V DC testbed is being developed in FREEDM systems center. The 400V system is shown in figure 1.4. It can be seen that there are several loads connected to DC bus some of which could be sensitive loads which need faster fault isolation in order to protect them from damage. In a real MVDC system, fault severity could be even higher owing to higher bus voltage. This thesis focuses on developing DC solid state circuit breaker hardware for 400V system shown in figure 1.4. Simulations are also performed for a 7.5kV MVDC system using different devices and results are compared.
Show more

112 Read more

A Design of Intelligent controller for controlled switching of circuit Breaker

A Design of Intelligent controller for controlled switching of circuit Breaker

Controlled opening refers to controlling the contact separation of each circuit breaker pole with respect to the phase angle of the current. Controlling the point of contact separation determines the arcing time of the contacts to help prevent breaker and circuit switcher failures and to minimize stress and disturbances to the power system. The implementation of controlled opening is approximately the same regardless of the equipment being switched. The control is straightforward once timing data for a breaker is available, particularly the time from energizing the trip coil to contact separation. Although controlled opening is best done using the current through the breaker, the bus voltage can be used if the voltage current phase relationship is always known, such as for shunt reactor and shunt capacitor switching. The breaker is controlled so that its contacts will part just after a current zero. As the contacts continue to open they draw out an arc that will extinguish less than a half cycle later at the next current zero. When the arc does extinguish, the contacts have been separated as far apart as practical, which provides the maximum dielectric strength available for the circumstances. This gives the breaker its best chance of successfully withstanding the recovery voltage and not having a re-ignition or a re- strike. Re-ignition is a dielectric breakdown that re- establishes current within 90 electrical degrees of interruption. Re-strike is a dielectric breakdown after 90 degrees. Figure shows the timing sequence for controlled opening. The control command is issued randomly with CIRCUIT
Show more

7 Read more

Automatic earth leakage circuit breaker with backup supply

Automatic earth leakage circuit breaker with backup supply

ELCB has become one of the home safety systems in our life today. ELCB has reset button which is to reclosed circuit breaker when the tripping occur. Today, many of people busy with work and usually not at home. The problem are during the over current, short circuit or current leakage at live conductor, it can trip the circuit breaker “OFF” and cut off the whole house power supply. This situation can make certain important component or equipment cannot be operated. Most household ELCB need to be reclosed manually during tripping, hence is a troublesome thing for user who is not at home and may be would take long time to reset on back the button at circuit breaker. The main mechanism in operation is tripping coil which is it can operation either in live or off condition. This ELCB will operate when current is exceeding the rating of the current ELCB. This high current not flows into equipment after ELCB tripped. It will flow directly into ground by using ground rod. This ground rod must has the lower resistance it because easy to flow high current. There are two types of ELCB[5]:-
Show more

39 Read more

Fault diagnosis method for energy storage mechanism of high voltage circuit breaker based on CNN characteristic matrix constructed by sound-vibration signal

Fault diagnosis method for energy storage mechanism of high voltage circuit breaker based on CNN characteristic matrix constructed by sound-vibration signal

Because of the selection of singular value and wavelet threshold for Singular value decomposition (SVD) and wavelet decomposition, denoising effects are not ideal. Based on the geometric characteristics of sound signals in energy storage process, morphology is transformed by structural elements to achieve signal matching, signal extraction, detail preservation, and noise suppression. It only needs algebraic operation without calculating frequency domain information and has a considerable speed [20]. Moreover, the highly efficient non-linear filtering function is very suitable for the noise signal filtering in the energy storage process of circuit breakers.
Show more

14 Read more

Evaluation of High-Voltage Circuit Breaker Performance with Modified Schavemaker Arc Model

Evaluation of High-Voltage Circuit Breaker Performance with Modified Schavemaker Arc Model

because these anode spots do not stop emitting ions at the current zero crossing. Their heat capacity enables the anode spots to evaporate anode material even when the power input is zero and thus can cause the vacuum arc not to extinguish. Directly after contact separation, when the arc ignites, evaporation of contact material is the main source of charged particles. When the contact distance increases, the evaporation of contact material remains the main source of charged particles for the vacuum arcs. For high-pressure arcs burning in air, oil, or SF 6 , the effect of evaporation of
Show more

6 Read more