• No results found

instantaneous reactive power compensation

Instantaneous Reactive Power Compensation and Voltage Stability with Thyristor Switch Capacitor (TSC) and Static Var Compensator (SVC)

Instantaneous Reactive Power Compensation and Voltage Stability with Thyristor Switch Capacitor (TSC) and Static Var Compensator (SVC)

... a power system to be termed as reliable it should not be affected by temporary overloads ,Voltage should be constant with very less loss in transmission and ...of compensation, viz .shunt and series .In ...

5

Comparison of Shunt Active Power Filter with Different Control Algorithms Using Particle Swarm Optimization Technique

Comparison of Shunt Active Power Filter with Different Control Algorithms Using Particle Swarm Optimization Technique

... providing compensation for harmonics, reactive power, and/or neutral current in ac ...active power filter is to inject opposing harmonic current to cancel the harmonics produced by nonlinear ...

12

A New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)

A New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)

... sinusoidal reference currents in the utility side those are in-phase with utility voltages too. Using this strategy makes it possible to regulate the voltage of DC side capacitor in a very simple manner by a closed loop ...

6

Performance Comparison of Shunt Active Power Filter with Different Control Algorithms Using Particle Swarm Optimization

Performance Comparison of Shunt Active Power Filter with Different Control Algorithms Using Particle Swarm Optimization

... providing compensation for harmonics, reactive power, and/or neutral current in ac ...active power filter is to inject opposing harmonic current to cancel the harmonics produced by nonlinear ...

11

Reactive Power Compensation by Controlling the DSTATCOM

Reactive Power Compensation by Controlling the DSTATCOM

... The instantaneous load power has two ...load power can be filtered by a set of either a low pass filter (cut off frequency 10Hz) or a moving average filter (averaging time 1/2f where f source ...For ...

7

Active AC/DC Voltage Source Converter with Function of Reactive Power Compensation for Neighboring Inductive Loads

Active AC/DC Voltage Source Converter with Function of Reactive Power Compensation for Neighboring Inductive Loads

... DC power supply with harmonic free ac-line ...for reactive power absorbed byneighboring ...system power factor and decrease the additional cost of compensating ...on instantaneous ...

6

A Simulation Model for Reactive Power Compensation

A Simulation Model for Reactive Power Compensation

... the reactive power is defined as the ac component of the instantaneous power, with a frequency equal to 100/120 Hz in a 50- or 60-Hz ...The reactive power generated by the ac ...

7

Article Description

Article Description

... The power quality at the distribution system is governed by various standards such as IEEE-519 standard ...to power quality problems are reported in the literature and are known by the generic name of ...

11

Simulation Analysis of Harmonic Eliminator using PQ Theory

Simulation Analysis of Harmonic Eliminator using PQ Theory

... the compensation of odd harmonics, reduces the THD and improve power quality compared to the other ...the power grid to improve the power ...

5

Research on Current Detection Method Based on Instantaneous Reactive Power Theory

Research on Current Detection Method Based on Instantaneous Reactive Power Theory

... b) In the case of voltage distortion, the harmonic power of the same frequency and the active power generated by the harmonic current are also dc components. In this case, the low-pass filter of the p-q ...

6

Series Active Power Filter Using Generalised Instantaneous Power Theory

Series Active Power Filter Using Generalised Instantaneous Power Theory

... active power filtering, with an objective to reduce inverter capacity, the Series Hybrid Active Power Filter (SHAPF) has been taken into account ...Generalised Instantaneous Power Theory ...

5

A Review on Reactive Power Compensation Techniques Using Power Filter

A Review on Reactive Power Compensation Techniques Using Power Filter

... When integrated to the power system, large wind farms pose stability and control issues. A through study is needed to identify the potential problems and to develop. This thesis investigates the use of a Static ...

6

Reactive Power Compensation for LV Distribution Network

Reactive Power Compensation for LV Distribution Network

... Fig. 6.3 Voltage profile of system for 20% load increment It can be seen that the voltage at different buses are within the limit between 0.920 to 1.00 pu when decentralized capacitor is used for reactive ...

8

Fuzzy Decision Method Applied in Action of Reactive Power Compensation Devices in Wind System

Fuzzy Decision Method Applied in Action of Reactive Power Compensation Devices in Wind System

... Fuzzy Multi-Attribute Decision Making Theory Applied in Wind Power System’s Reactive Power Compensation Device Action Plan Optimization It assumes that available reactive power compensat[r] ...

8

Importance of TSC on Reactive Power Compensation for Power Quality Improvement

Importance of TSC on Reactive Power Compensation for Power Quality Improvement

... absorb reactive energy have been increased with either developments at technology or rising of wealth level in offices and ...In power systems, load models are classified into two categories: static load ...

11

Research on Active Management Strategy of Distributed Power Supply Access to Distribution Network

Research on Active Management Strategy of Distributed Power Supply Access to Distribution Network

... distributed power generation access, the voltage on the line along the direction away from the distribution of continuous ...distributed power generation access line, the line on the trend changes, the ...

8

A Five Level DSTATCOM for Compensation of Reactive Power and Harmonics

A Five Level DSTATCOM for Compensation of Reactive Power and Harmonics

... A multilevel inverter can reduce the device voltage and the output harmonics by increasing the number of output voltage levels. There are several types of multilevel inverters: cascaded H-bridge (CHB), neutral point ...

7

Design and implementation of TSC-TCR for reactive power compensation

Design and implementation of TSC-TCR for reactive power compensation

... new kind of measure to control volt ,svc can rapidly and continuously adjust volt of installation area. this paper kind of svc system that include TSC-TCR section though simulink of matlab.the simulation result show that ...

6

Fuzzy Controller For Reactive Power Compensation With Statcom To Improve Power Factor

Fuzzy Controller For Reactive Power Compensation With Statcom To Improve Power Factor

... the reactive power for improvement of power factor on the variation of DC link ...the reactive power we are introduced fuzzy controller for the improvement of power factor with ...

11

Fuzzy Controller for Reactive Power Compensation with Statcom to Improve Power Factor

Fuzzy Controller for Reactive Power Compensation with Statcom to Improve Power Factor

... Varsha L. Bade received her B. E. degree in Electrical Electronics and Power (EEP) from M.B.E. Society’s, College of Engineering, Ambajogai, India,in 2014, and pursuing M.E. degree in Control System Engineering ...

12

Show all 10000 documents...

Related subjects