• No results found

Locked plating

Does Single Locked Plating Provide A standard treatment
Modality for Bicondylar tibial Plateau Fractures? A prospective study

Does Single Locked Plating Provide A standard treatment Modality for Bicondylar tibial Plateau Fractures? A prospective study

... lateral locked plating is less effective for fractures with coronal medial fracture ...of locked screws is fixed and is, for the most part, parallel rather than perpendicular to a coronal fracture ...

8

Clinical outcomes of locked plating of distal femoral fractures in a retrospective cohort

Clinical outcomes of locked plating of distal femoral fractures in a retrospective cohort

... Except in extreme circumstances, operative treatment for supracondylar femoral fractures is the standard, while nonsurgical treatment has largely fallen out of favor as the result of further advances in technique and ...

9

Is immediate weight bearing safe for periprosthetic distal femur fractures treated by locked plating? A feasibility study in 52 consecutive patients

Is immediate weight bearing safe for periprosthetic distal femur fractures treated by locked plating? A feasibility study in 52 consecutive patients

... We treated a consecutive cohort of 52 patients with periprosthetic distal femur fractures with a standardized approach including early surgery, minimally invasive locked plating and early mobilization ...

5

Quality of life after volar locked plating: a 10 year follow up study of patients with intra articular distal radius fractures

Quality of life after volar locked plating: a 10 year follow up study of patients with intra articular distal radius fractures

... The study design, patient recruitment and surgical tech- nique were published in our previous cohort analysis [10]. The study protocol was approved by the local eth- ics committee (Ethics committee of the Medical Univer- ...

7

A Finite Element Model of Locked Plating in Femoral Shaft Fractures

A Finite Element Model of Locked Plating in Femoral Shaft Fractures

... compression plating bridging plastic pipes in that strain was minimized when the screws were placed farthest from the fracture (increased working length) in the “no gap” ...compression plating studies are ...

9

Comparison of outcomes and analysis of risk factors for non-union in locked plating of closed periprosthetic and non-periprosthetic distal femoral fractures in a retrospective cohort study

Comparison of outcomes and analysis of risk factors for non-union in locked plating of closed periprosthetic and non-periprosthetic distal femoral fractures in a retrospective cohort study

... Although non-weightbearing is commonly the practice followed in many centres, recent studies [7, 46] have shown successful outcomes including high union rates in patients allowed full weightbearing after locked ...

10

Current concepts to reduce mechanical stiffness in locked plating systems: a review article

Current concepts to reduce mechanical stiffness in locked plating systems: a review article

... Far cortical locking (FCL) is an approach requiring special- ized screws in a locking plate. FCL aims to reduce stiffness whilst maintaining strength of a construct. The screws have th[r] ...

5

Pronator quadratus repair after volar plating of distal radius fractures or not? Results of a prospective randomized trial

Pronator quadratus repair after volar plating of distal radius fractures or not? Results of a prospective randomized trial

... volar locked plating of distal radius fractures only a posi- tive trend could be shown on forearm pronation strength in the early postoperative period of 3 ...volar plating of distal radius fractures ...

8

Biomechanical Investigation of Locked Plate Fixation with Suture Augmentation in a Comminuted Three Part Proximal Humerus Fracture Model

Biomechanical Investigation of Locked Plate Fixation with Suture Augmentation in a Comminuted Three Part Proximal Humerus Fracture Model

... [1]-[6]. Locked plate technology has emerged as a tool to improve fixation in osteoporotic bone and affords the surgeon the option of fixing fractures previously relegated to management by ...standard ...

12

Failure of volar locking plate fixation of an extraarticular distal radius fracture: A case report

Failure of volar locking plate fixation of an extraarticular distal radius fracture: A case report

... Volar locked plating represents the new “gold standard” of distal radius fracture ...volar locked plating, particularly in patients with a high risk of developing a ...

6

An Electroless Plating   A Review Paper

An Electroless Plating A Review Paper

... the plating quality (adhesion and appearance) was obtained from the activation in zincate and palladium chloride ...Higher plating rates (g/mm2/min) of ...

5

Investigations on the Characteristics of Pulse Plating on Printed Circuit Board

Investigations on the Characteristics of Pulse Plating on Printed Circuit Board

... Printed Circuit Boards (PCB) are the vital components of any electronic system. They are made of glass fiber with reinforced epoxy resin. Here efforts are taken to optimize the plating characteristics of a double ...

6

Rhodium Plating to Specification13-18

Rhodium Plating to Specification13-18

... Most of the metals and alloys commonly used may readily be rhodium plated directly, although for reasons of skin conductivity, exposure to high temperatures or other spe[r] ...

6

Study of Tantalum nitride diffusion barrier films for coppper interconnect technology

Study of Tantalum nitride diffusion barrier films for coppper interconnect technology

... When this de-plating the it current constant layer is less than the in figure 4.4, giving lesser thickness than that electrolytic solution The is thus causing under plating of wafer and [r] ...

112

Firearm Ownership and Storage Patterns Among Families With Children Who Receive Well-Child Care in Pediatric Offices

Firearm Ownership and Storage Patterns Among Families With Children Who Receive Well-Child Care in Pediatric Offices

... a locked cabinet but to store ammuni- tion separate from their ...guns locked or use a gun lock but least likely to store bullets separately from their ...

11

Electroplating   Plating Metals pdf

Electroplating Plating Metals pdf

... The hard chromium electroplating industry has been affected by numerous air quality regulations on both the state and federal levels. In 1995, the U.S. Environmental Protection Agency promulgated its National Emission ...

212

Electroless Plating on Porous Carbon Felts in Redox Flow Batteries and Thickness Effect on the Electrical and Mechanical Properties

Electroless Plating on Porous Carbon Felts in Redox Flow Batteries and Thickness Effect on the Electrical and Mechanical Properties

... electroless plating technique on the carbon felt, the effects of plating thickness and relevant impact on the mechanical, electrical and morphological properties is ...

11

Polarization Behavior of Electroless Ni-P Plating on Magnesium Alloys

Polarization Behavior of Electroless Ni-P Plating on Magnesium Alloys

... complete plating bath (Curve a in ...three plating bath indicated that the sum of partial contributions could not represent the experimental result obtained in a complete ...

14

Title: Analysis and Design of a Three-Phase PLL Structure

Title: Analysis and Design of a Three-Phase PLL Structure

... phase locked loops detects phase angle ...phase locked loop with proper controller is proposed which detects phase appropriately in balanced situation of input ...

6

Interlocking Nailing Versus Plating in Tibial Shaft Fractures in Adults: A Comparative Study

Click here to download PDF version of the article !

... The patients were taken up for surgery after all routine preoperative investigations were found to be within normal limits. Fifty six patients with 62 affected limbs were included in the study. After obtaining due ...

6

Show all 878 documents...

Related subjects