• No results found

neutron time-of-flight data

Crystal structure of magnesium selenate heptahydrate, MgSeO4·7H2O, from neutron time of flight data

Crystal structure of magnesium selenate heptahydrate, MgSeO4·7H2O, from neutron time of flight data

... the data pertaining to the sulfate, but it is worth observing that the neutron scattering cross-section of selenium is almost three times greater than that of sulfur so our result should be considered more ...

9

Crystal structure of magnesium selenate hepta­hydrate, MgSeO4·7H2O, from neutron time of flight data

Crystal structure of magnesium selenate hepta­hydrate, MgSeO4·7H2O, from neutron time of flight data

... these was removed from the liquid, dried on filter paper and cut into a pair of fragments each with dimensions 1 x 1 x 4 mm. The two fragments were placed side-by-side in an aluminium foil pouch suspended inside a ...

8

Structure of magnesium selenate enneahydrate, MgSeO4·9H2O, from 5 to 250 K using neutron time of flight Laue diffraction

Structure of magnesium selenate enneahydrate, MgSeO4·9H2O, from 5 to 250 K using neutron time of flight Laue diffraction

... Structure refinement was carried out using SHELX2014 (Sheldrick, 2008; Gruene et al., 2014) starting from the atomic coordinates – including estimated H positions – determined by the structure solution from X-ray powder ...

16

Glycine zinc sulfate penta­hydrate: redetermination at 10 K from time of flight neutron Laue diffraction

Glycine zinc sulfate penta­hydrate: redetermination at 10 K from time of flight neutron Laue diffraction

... Howard et al. (2016) and is in excellent agreement with the spectrum shown in Tepavitcharova et al. (2012). Numerical data of the Raman spectrum are provided as an electronic supplement; peak positions and ...

13

Fast neutron measurements at the nELBE time-of-flight facility

Fast neutron measurements at the nELBE time-of-flight facility

... the neutron beam, whereby the uranium chamber was placed closer to the neutron ...The flight path of the neutrons was between ...individual data acquisition ...

6

Crystal structures of deuterated sodium molybdate dihydrate and sodium tungstate dihydrate from time of flight neutron powder diffraction

Crystal structures of deuterated sodium molybdate dihydrate and sodium tungstate dihydrate from time of flight neutron powder diffraction

... coherent neutron scattering lengths of the constituent elements differ by less than a factor of two, being ...incoherent neutron scattering cross section of 1 H is large ...These data were therefore ...

14

Residual Thermal Phase Stresses in α γ Fe Cr Ni Alloys Measured
by a Neutron Diffraction Time of Flight Method

Residual Thermal Phase Stresses in α γ Fe Cr Ni Alloys Measured by a Neutron Diffraction Time of Flight Method

... The obtained results are displayed in Fig. 7. Consistently with the thermal expansion coefficient data, the strains in γ phase were positive and those in α phase were negative, showing good agreements with those ...

7

Neutron induced fission of 237Np – status, challenges and opportunities

Neutron induced fission of 237Np – status, challenges and opportunities

... in neutron-induced reaction experimental data repositories and in the present evaluated data libraries, based on the different sets of experimental data (see ...different data libraries ...

6

Quasielastic neutron scattering experiment on water using TOFLAR (Time Of Flight and LARmor precession) technique at SNS

Quasielastic neutron scattering experiment on water using TOFLAR (Time Of Flight and LARmor precession) technique at SNS

... The aim of a quasielastic scattering experiment is to extract F (Q, t ) and to test various dynamical models against it. Raw data (described by Eq. (3)) contain a few variables that can be removed by a suitable ...

6

Silicon Revisited: Understanding Pure Phonon Anharmonicity and the Effects on Thermophysical Properties

Silicon Revisited: Understanding Pure Phonon Anharmonicity and the Effects on Thermophysical Properties

... optimal neutron scat- tering ...geometry time-of-flight inelastic neutron scattering spectrometer (ARCS) [25] at the Spallation Neutron Source at Oak Ridge National ...(q,ε) data ...

116

Present status and future programs of the n_TOF experiment

Present status and future programs of the n_TOF experiment

... precision neutron cross-section data are of major importance for a wide variety of research fields in basic and applied nuclear physics ...particular, neutron data on neutron-nucleus ...

13

The measurement programme at the neutron time-of-flight facility n_TOF at CERN

The measurement programme at the neutron time-of-flight facility n_TOF at CERN

... the data available for further use in nuclear data ...measured data for a typical measurement are a set of detector count spectra as a function of neutron ...nuclear data evaluations, ...

6

Neutron xyz – polarization analysis at a time-of-flight instrument

Neutron xyz – polarization analysis at a time-of-flight instrument

... beneficial to expand the traditional 6-pt protocol, because this allows one to fully cancel out the angles and minimize the set of assumptions in the data analysis. It may also be pointed out that at an instrument ...

6

Crystal structures of deuterated sodium molybdate dihydrate and sodium tungstate dihydrate from time of flight neutron powder diffraction

Crystal structures of deuterated sodium molybdate dihydrate and sodium tungstate dihydrate from time of flight neutron powder diffraction

... as a function of hydrostatic pressure (to 5 GPa). Both compounds exhibit evidence of a ‘conformational change’ on cooling through 120 K: the molybdate appears to undergo two high-pressure phase transitions, one at 3 GPa ...

15

Neutron inelastic scattering of 232Th: measurements and beyond

Neutron inelastic scattering of 232Th: measurements and beyond

... reactions using prompt gamma spectroscopy. Incident neutron energies were determined using the neutron time-of-flight technique. Sources of uncertainty have been examined and their ...

7

Kinematics analysis of selected rhytmic gymnastic leaps

Kinematics analysis of selected rhytmic gymnastic leaps

... During flight phase, technical figures are performed by the ...reaction time, explosive leg power and average jump height in elite level gymnasts for leap training evaluation purposes, but they did not ...

8

Development of a predictive model for on-time arrival flight of airliner by discovering correlation between flight and weather data

Development of a predictive model for on-time arrival flight of airliner by discovering correlation between flight and weather data

... arrival flight is proposed with using flight data and weather ...between flight data and weather ...and flight data of Peach Aviation, which is LCC (low-cost carrier) in ...

17

Evaluation of stable tungsten isotopes in the resolved resonance region

Evaluation of stable tungsten isotopes in the resolved resonance region

... the neutron time of flight facility GELINA (Geel Electron LINear ...slow neutron component is enhanced by using a water moderator canned in ...m flight path stations at 800 and 50 Hz ...

5

Real time capabilities of a digital analyzer for mixed field assay using scintillation detectors

Real time capabilities of a digital analyzer for mixed field assay using scintillation detectors

... acquiring data, and the filtering influence is displayed in real ...the time taken for the HV to stabilize and acquire an adequate data ...137 data acquired from an EJ309 liquid ...and ...

6

ANALYSIS OF TIME-OF-FLIGHT DIFFRACTION DATA FROM LIQUID AND AMORPHOUS SAMPLES

ANALYSIS OF TIME-OF-FLIGHT DIFFRACTION DATA FROM LIQUID AND AMORPHOUS SAMPLES

... Furthermore our experience to date has shown that there really is no fundamental barrier to diffraction data being accurately analysed to structure factor or even pair [r] ...

8

Show all 10000 documents...