• No results found

open-ended coaxial probe method

An Improved Method for Microwave Nondestructive Dielectric Measurement of Layered Media

An Improved Method for Microwave Nondestructive Dielectric Measurement of Layered Media

... using open-ended coaxial (OEC) probe [21– 24], open-ended rectangular waveguide [25–28] and free-space method ...OEC probe due to its simplicity and accuracy in ...

17

Measurement of the complex dielectric constant down to helium temperatures. I. Reflection method from 1 MHz to 20 GHz using an open ended coaxial line

Measurement of the complex dielectric constant down to helium temperatures. I. Reflection method from 1 MHz to 20 GHz using an open ended coaxial line

... an open ended coaxial probe pressed against a material under test is used to determine the complex microwave 共 1 MHz–20 GHz 兲 dielectric response of the ...the probe, in terms of the ...

6

A Broadband Complex Permittivity Probe Using Stepped Coaxial Line

A Broadband Complex Permittivity Probe Using Stepped Coaxial Line

... SMA coaxial connectors have been applied to be open-ended coaxial ...The probe structure is very simple and conven- ient for complex permittivity ...new probe using a modified ...

7

Fast and Stable Integration Method for the Aperture Admittance of an Open-Ended Coaxial Probe Terminated into
 Low-Loss Dielectrics

Fast and Stable Integration Method for the Aperture Admittance of an Open-Ended Coaxial Probe Terminated into Low-Loss Dielectrics

... MUTs are shown in Fig. 3. Firstly, comparison between TIM and CIT indicates that they render the same calculated values in the whole frequency range for different dielectrics. This is attributed to the same theoretical ...

9

Systematization of reliable open ended networks

Systematization of reliable open ended networks

... of open ended networks using Wiener ...constructed open ended networks by introducing new ...new open ended networks have been done and compared with existing open ...

6

Study Of Different Etmsa For Wideband Application

Study Of Different Etmsa For Wideband Application

... feed method is easy to fabricate and has low spurious radiation ...increased probe length makes the input impedance more inductive, leading to matching ...

6

Open-Ended Interview Questions and Saturation

Open-Ended Interview Questions and Saturation

... In this article, we estimate the point of complete thematic saturation and the associated sample size and domain size for 28 sets of interviews in which respondents were asked to list all the things they could think of ...

20

Dielectric characterization of vegetation at L band using an open-ended coaxial probe

Dielectric characterization of vegetation at L band using an open-ended coaxial probe

... the probe could be used to monitor the hydraulic properties of trees including water storage and the amount of frozen water in the ...the probe will have to be ...the probe over full seasonal cycles ...

14

Determination of quality and storage-time of dielectric mixtures using time domain spectroscopy

Determination of quality and storage-time of dielectric mixtures using time domain spectroscopy

... Abstract. This paper presents a novel approach for deter- mining certain material properties from permittivity mea- surements. It does not rely on physical models and mixture formulas. Instead, the reflection time domain ...

5

Comparative Kinetic Analysis of Closed Ended and Open Ended Porous Sensors

Comparative Kinetic Analysis of Closed Ended and Open Ended Porous Sensors

... the open-ended membranes to provide process tol- erance during membrane fabrication and mechanical support but were also included in the closed-ended PSi samples for ...mm open-ended ...

9

The Use of Open Ended versus Closed Ended Questions in Turkish Classrooms

The Use of Open Ended versus Closed Ended Questions in Turkish Classrooms

... of open ended questions after ...more open ended questions than the experienced ...more open to changes in teaching practice; however, experienced teachers may have had difficulties ...

11

Construction and Implementation of Coaxial Probe Feed Microstrip Patch Array Antenna

Construction and Implementation of Coaxial Probe Feed Microstrip Patch Array Antenna

... II. MICROSTRI P PATCH ARRAY ANTENNA In this paper, coaxial probe feed patch antenna array has been designed by using feeder network in circuit design at a center frequency of 1.48GHz using a dielectric ...

8

Rigorous Closed Form Expressions for the Input Admittance of  a Coaxial Probe Radiating into
 a Lossy Parallel Plate Waveguide. a Dyadic Green's Function Approach.

Rigorous Closed Form Expressions for the Input Admittance of a Coaxial Probe Radiating into a Lossy Parallel Plate Waveguide. a Dyadic Green's Function Approach.

... The parallel plate waveguide, PPWG henceforth, is the simplest waveguiding structure available and is studied in every textbook of engineering electromagnetics. In spite of its simplicity, PPWG has been used to realize ...

15

Precision Permittivity Measurement for Low-Loss

Precision Permittivity Measurement for Low-Loss

... Keywords: large coaxial probe, thin planar materials, low-loss materials, relative permittivity, reflection 20.. coefficient, calibration.[r] ...

8

A Novel Broadband Coaxial Probe to Conical Wire Transition at THz
 Frequency

A Novel Broadband Coaxial Probe to Conical Wire Transition at THz Frequency

... the coated conical metal wire and uncoated conical metal wire were much larger than those around the coated cylindrical metal wire. Through the simulation results, it is clearly that both the coated conical metal wire ...

15

EQ UI L A TE RAL TR I A NGU L A RM I C RO S TR I P ANTE NNA FO RC I R CU L A RL Y- P OL AR I Z E D S YNTHE TI CA P E R TU READR .B a h a r u d d i n , V . Wi s s a n , J . T. S . S u ma n t y o, a n dH. Ku z e

EQ UI L A TE RAL TR I A NGU L A RM I C RO S TR I P ANTE NNA FO RC I R CU L A RL Y- P OL AR I Z E D S YNTHE TI CA P E R TU READR .B a h a r u d d i n , V . Wi s s a n , J . T. S . S u ma n t y o, a n dH. Ku z e

... The configuration of the radiating element together with the microstrip line feed and ground plane is shown in Fig. 2(a), where important parameters are labeled. Side view is depicted in Fig. 2(b). The equilateral ...

14

Rectangular Microstrip patch antenna using coaxial probe feeding technique on different dielectric constant for instrumentation and receivers

Rectangular Microstrip patch antenna using coaxial probe feeding technique on different dielectric constant for instrumentation and receivers

... “Rectangular Microstrip patch antenna using coaxial probe feeding technique on different dielectric constant for instrumentation and receivers”, International Journal of Current Research[r] ...

10

Clustering students' open ended questionnaire answers

Clustering students' open ended questionnaire answers

... A common special technique used in short text clustering and information retrieval is document expansion. The underlying idea is to create the missing context by augmenting short texts, for example with web search ...

14

An EFficient Method for Computing the Interaction of Open Ended Circular Waveguide with a Layered Media

An EFficient Method for Computing the Interaction of Open Ended Circular Waveguide with a Layered Media

... transform method to calculate the input admittance of an air filled circular waveguide covered with dielectric ...the method in [6] for calculating the reflection coefficient, and thereby complex dielectric ...

7

Amplitude-Only Measurements of a Dual Open Ended Coaxial Sensor System for Determination of Complex Permittivity of Materials

Amplitude-Only Measurements of a Dual Open Ended Coaxial Sensor System for Determination of Complex Permittivity of Materials

... dual open ended coaxial sensor system requiring only amplitude measurements of the reflection coefficients from two different open-ended coaxial sensors to calculate the complex ...

13

Show all 10000 documents...

Related subjects