• No results found

parallel output

Modular input-parallel output-series DC/DC converter control with fault detection and redundancy

Modular input-parallel output-series DC/DC converter control with fault detection and redundancy

... Abstract: Large offshore wind farms require extensive sub-sea cables within the collection network. Present solutions are based around medium-voltage AC collection networks. Recent studies have highlighted the potential ...

19

Modular input-parallel-output-series DC/DC converter control with fault detection and redundancy

Modular input-parallel-output-series DC/DC converter control with fault detection and redundancy

... Currently, the open literature contains few publications in the field of the IPOS converter and its control strategy. Normally, the average active sharing method or the master-slave active sharing method is chosen to ...

8

Active power sharing in input-series-input-parallel output-series connected DC/DC converters

Active power sharing in input-series-input-parallel output-series connected DC/DC converters

... input-series-input-parallel output-series (ISIPOS) connection of modules is proposed. Parallel-series architectures can be classified into four categories based on their ...input parallel ...

8

A High Gain Input-Parallel Output-Series Interleaved Boost Converter for Home Appliances

A High Gain Input-Parallel Output-Series Interleaved Boost Converter for Home Appliances

... The proposed interleaved boost converter with dual coupled inductor based topology is used to convert the given low input voltage to higher voltage and hence producing high voltage gain. Interleaved converters can ...

15

070205C CGC 7900 Parallel Output DMA Nov1983 pdf

070205C CGC 7900 Parallel Output DMA Nov1983 pdf

... Once the CPU has determined that the output port desired is available for transfer, a write operation is performed to the appropriate location in memory~ On the trailing low to high tran[r] ...

77

A Parallel Input Series Output  DC/DC Converter with High Voltage Gain

A Parallel Input Series Output  DC/DC Converter with High Voltage Gain

... in parallel and output in ...in parallel and secondary windings in series a high step up DC/DC converter is ...input parallel output series boost converter with dual coupled inductors ...

6

Impedance interaction between islanded parallel voltage source inverters and the distribution network

Impedance interaction between islanded parallel voltage source inverters and the distribution network

... in parallel to become unstable. Power sharing between parallel-connected DGs can be achieved using the well-known droop control ...inverter’s output impedance without using additional physical ...

7

Analysis of Fast Fourier Transform (FFT) Of Phase Staggered Pulse Width Modulator for Two Switch Forward Converter

Analysis of Fast Fourier Transform (FFT) Of Phase Staggered Pulse Width Modulator for Two Switch Forward Converter

... in output voltage FFT and output current FFT ...with parallel input and serial output to demonstrate the impact of phase staggering on 50 kHz (switching frequency) component of output ...

8

Comparison of Traditional Approach for Edge Detection with Soft Computing Approach

Comparison of Traditional Approach for Edge Detection with Soft Computing Approach

... which few edges left by being detected. Fuzzy logic a branch of soft computing provides us flexibility by allowing the values without any such restrictions. Fuzzy logic have IF- THEN rules and have simple structure to ...

7

Design of DC To DC Converter for Hybrid Wind Solar Energy System

Design of DC To DC Converter for Hybrid Wind Solar Energy System

... the output of the PV array and the other input connected to the output of a generator ...converters output is combined and it is given to the rectifier ...

9

An Overview on Piezoelectric  Power Generation System for Electricity Generation

An Overview on Piezoelectric Power Generation System for Electricity Generation

... the output current, but also match the equivalent load of energy storage ...the output power of AC-DC-DC conver- ter is almost 3 times greater than AC-DC converter ...

9

RIOT : a parallel input/output tracer

RIOT : a parallel input/output tracer

... trace parallel file opera- tions performed by the ROMIO message passing interface input/output (MPI- IO) layer [16] and relate these to underlying POSIX operations including file locking, unlocking and ...

16

Power Flows and Torque Analyses of an Independently Controllable Transmission with a Parallel Type

Power Flows and Torque Analyses of an Independently Controllable Transmission with a Parallel Type

... n the automation engineering, many applications have widely employed infinitely and continuously variable transmission (IVT, CVT), because CVTs are capable of providing any ratio between output and input speeds. ...

5

Coreference Resolution for Swedish and German using Distant Supervision

Coreference Resolution for Swedish and German using Distant Supervision

... Parallel corpora have been used to transfer syntac- tic annotation. Hwa et al. (2005) is an example of this. In the case of coreference, Rahman and Ng (2012) used statistical machine translation to align words and ...

10

A High Efficiency Balanced Frequency Tripler Incorporating Compensation Structure for Millimeter-Wave Applications

A High Efficiency Balanced Frequency Tripler Incorporating Compensation Structure for Millimeter-Wave Applications

... the output circuit is composed of the right compensation solder pad, optimized output matching network and the low insertion loss transition from the microstrip to the ...the output port, while the ...

10

The topology of connections between rat prefrontal, motor and sensory cortices

The topology of connections between rat prefrontal, motor and sensory cortices

... and output connections to and from prefrontal regions shows an ordered arrange- ment of connections occurring in and across three axes of orientation, most significantly so in the anterior-posterior and ...

10

133002-00_Televideo_9320_Video_Display_Terminal_Maintenance_Manual_Aug88.pdf

133002-00_Televideo_9320_Video_Display_Terminal_Maintenance_Manual_Aug88.pdf

... The character generator data that goes into the gate array is shifted from parallel to serial data, and is combined with attribute data, the BLANK output of the CRT controller,[r] ...

57

Solar AC Generator

Solar AC Generator

... AC output, wave the solar cell pair is connected in ...AC output terminals are Aout and ...AC output terminal Aout, while the remaining solar cells represented by solar cells B1, B2, B3, B4 and B5 ...

5

Design of a Self-test Vehicle for AC Coupled Interconnect Technology

Design of a Self-test Vehicle for AC Coupled Interconnect Technology

... Since the Pattern Detector has to generate the expected data values to compare with the incoming data, it contains another instance of the Pattern Generator module, same as the one on the transmit side. When the reset is ...

108

Time-Interleaved Delta-Sigma Modulator for Wideband Digital GHz
 Transmitters Design and SDR Applications

Time-Interleaved Delta-Sigma Modulator for Wideband Digital GHz Transmitters Design and SDR Applications

... time-interleaved parallel modulator that need to work in original clock, are delays and down-samplers at the input and up-samplers and delays at the output of modulator as shown in ...

19

Show all 10000 documents...

Related subjects