• No results found

Percutaneous aortic valve replacement

Transcatheter versus surgical aortic valve replacement: a systematic review and meta-analysis of randomised and non-randomised trials

Transcatheter versus surgical aortic valve replacement: a systematic review and meta-analysis of randomised and non-randomised trials

... trans-catheter aortic valve implantation, percutaneous aortic valve implantation, percutaneous aortic valve replacement, transfemoral aortic ...

8

Determinants of clinical improvement after surgical replacement or transcatheter aortic valve implantation for isolated aortic stenosis

Determinants of clinical improvement after surgical replacement or transcatheter aortic valve implantation for isolated aortic stenosis

... CoreValve Percutaneous System, Medtronic CV) was implanted in 11 ...Two valve sizes were available, 23- and 26-mm expanded diameter for Edwards SAPIEN valve and 26- and 29-mm for ...

10

Imaging techniques in transcatheter aortic valve replacement

Imaging techniques in transcatheter aortic valve replacement

... the valve opening, but the fused raphe results in a nonuniform ...bicuspid valve is considered a limitation of percutaneous treatment of aortic valve stenosis, then correct ...

13

Abstract Introduction: Other aortic interventions are often compared to surgical aortic valve replacement (SAVR),

Abstract Introduction: Other aortic interventions are often compared to surgical aortic valve replacement (SAVR),

... Transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN valve was superior to medical therapy in the treatment of inoperable patients with aortic stenosis (cohort B) and ...

5

Immediate and Evolutionary Recovery of Left Ventricular Diastolic Function after Transcatheter Aortic Valve Replacement: Comparison with Surgery

Immediate and Evolutionary Recovery of Left Ventricular Diastolic Function after Transcatheter Aortic Valve Replacement: Comparison with Surgery

... abdominal aortic an- eurysm, bleeding diathesis or coagulopathy, creatinine clear- ance <20 mL/min, and life expectancy <1 ...by percutaneous coronary intervention before ...

10

Vol 1, No 2 (2013)

Vol 1, No 2 (2013)

... of valve disease in modern ...surgical valve replacement remains the gold standard treatment for survival benefit, durability and symptomatic ...relief. percutaneous transcatheter ...

6

Exercise-based cardiac rehabilitation for patients following open surgical aortic valve replacement and transcatheter aortic valve implant: a systematic review and meta-analysis

Exercise-based cardiac rehabilitation for patients following open surgical aortic valve replacement and transcatheter aortic valve implant: a systematic review and meta-analysis

... This systematic review and meta-analysis aimed to eval- uate the efficacy, safety and costs of exercise-based CR in TAVI or SAVR patients. In addition to RCTs, we also included non-RCTs to allow us evaluate the safety of ...

8

Usefulness of Del Nido cardioplegia in adult cardiac surgery.

Usefulness of Del Nido cardioplegia in adult cardiac surgery.

... John Gibbon found that only 9 out of 142 who had undergone procedures worldwide were alive after the procedure. This made him think about the work on pump oxygenator which could maintain circulation. He initiated the use ...

60

Effect of postoperative positive airway pressure on risk of postoperative atrial fibrillation after cardiac surgery in patients with obstructive sleep apnea: a retrospective cohort study

Effect of postoperative positive airway pressure on risk of postoperative atrial fibrillation after cardiac surgery in patients with obstructive sleep apnea: a retrospective cohort study

... tion, valve surgery, chronic obstructive pulmonary disease, and perioperative withdrawal of beta-blockers—are associ- ated with POAF after cardiac surgery (Mathew et ...

7

Atypical Presentation of Unicuspid Unicommissural Aortic Valve in Infant

Atypical Presentation of Unicuspid Unicommissural Aortic Valve in Infant

... annulus, aortic valve has no commissures and appears as a pinhole opening on Echocardiogram; and if it grows in with two coaptation points, there is one lateral commissural attachment to the aorta at the ...

5

Percutaneous heart valves; past, present and future

Percutaneous heart valves; past, present and future

... fully percutaneous access to the common femoral ...reduce aortic flow and prevent distal migration of the ...native valve. Once in the correct position, the valve is unsheathed to enable the ...

22

Journal of Applied Pharmaceutical Science

Journal of Applied Pharmaceutical Science

... We could not trace the patients’ serum albumin level in this study. However, except patients with some underlying diseases like persistent sepsis, hepatic impairment, nephrotic syndrome or hyperthyroidism that decreased ...

6

Vol 6 (2016)

Vol 6 (2016)

... the valve in valve procedure feasible and effective [see figure 1], although in all but four cases [CRS 26 into a predominantly regurgitant Pericarbon Freedom 21, CRS 26 into a predominantly stenosed ...

7

Cardiovascular magnetic resonance assessment of 1st generation CoreValve and 2nd generation Lotus valves

Cardiovascular magnetic resonance assessment of 1st generation CoreValve and 2nd generation Lotus valves

... pacemaker replacement or death, which may have introduced bias, although the final analysed population did not differ from the recruited population in terms of demographics and ...

20

Cardiovascular magnetic resonance assessment of 1st generation CoreValve and 2nd generation Lotus valves

Cardiovascular magnetic resonance assessment of 1st generation CoreValve and 2nd generation Lotus valves

... for aortic valve regurgitation, haemodynamics and impact on LV reverse remodelling over ...of aortic regurgitation immediately post-replacement, with over a third of patients having at least ...

20

Comparison 30-day clinical complications between transfemoral versus transapical aortic valve replacement for aortic stenosis: a meta-analysis review

Comparison 30-day clinical complications between transfemoral versus transapical aortic valve replacement for aortic stenosis: a meta-analysis review

... device. Valve implantation was performed using the first generation Edwards SAPIEN prosthesis (Edwards Lifescience, Irvine, CA) or the Medtronics COREVALVE (Med tronics ...large aortic annulus (diameter ...

7

Quantitative assessment of paravalvular regurgitation following transcatheter aortic valve replacement

Quantitative assessment of paravalvular regurgitation following transcatheter aortic valve replacement

... regurgitant aortic flows using through- plane phase-contrast velocity mapping (free breathing, retrospective gating) (Figure ...the aortic valve at end-diastole, but a position in the aortic ...

6

One stage surgical treatment of aortic valve disease and aortic coarctation with aortic bypass grafting through the diaphragm and aortic valve replacement

One stage surgical treatment of aortic valve disease and aortic coarctation with aortic bypass grafting through the diaphragm and aortic valve replacement

... Treatment options include surgery, balloon angio- plasty and endovascular stenting. Stent implantation has gained great success and become a widely accepted therapeutic option for CoA in children and adults during the ...

5

Original Article microRNA-194 in the development of aortic aneurysms and dissection

Original Article microRNA-194 in the development of aortic aneurysms and dissection

... the aortic wall was signifi- cantly increased in patients with aortic aneu- ...the aortic wall and play a key role in the pathogen- esis of aortic dissection ...

8

Early Doppler-echocardiography evaluation of Carpentier-Edwards Standard and Carpentier-Edwards Magna aortic prosthetic valve: comparison of hemodynamic performance

Early Doppler-echocardiography evaluation of Carpentier-Edwards Standard and Carpentier-Edwards Magna aortic prosthetic valve: comparison of hemodynamic performance

... of valve types available on the market, and multicenter echocardiographic assessment ...functioning aortic prosthetic valve, similar to a native valve, assuming as normal value a DVI ...

7

Show all 10000 documents...

Related subjects