• No results found

pull test

Analysis of morphology and tensile 
		strength of banana kapok fibres using a scanning electron micrograph (SEM) 
		and pull test equipment

Analysis of morphology and tensile strength of banana kapok fibres using a scanning electron micrograph (SEM) and pull test equipment

... Tensile test was conducted to determine the interfacial shear strength by embedding a single fibre banana fibre into the epoxy matrix as deep as 1 ...The test results showed that the soaking treatment ...

7

Reactive transport with wellbore storages in a single well push–pull test

Reactive transport with wellbore storages in a single well push–pull test

... (SWPP) test to determine the in situ biogeochemical reaction kinetics, a chase phase and a rest phase were recommended to increase the duration of reaction, besides the injection and extrac- tion ...SWPP ...

17

Bible binding techniques: Analysis of spine lining constructions and endpaper reinforcements

Bible binding techniques: Analysis of spine lining constructions and endpaper reinforcements

... 39 the Also, statistical following hypotheses There be will should no indicated that the differences in the Page-pull test Smyth-sewn hardcover Bible bindings 2 four-page tipped-on with [r] ...

79

Alternative Substrates for Estimating TCE-degrading Capabilities of Toluene-oxidizing Bacteria

Alternative Substrates for Estimating TCE-degrading Capabilities of Toluene-oxidizing Bacteria

... While cyclopentane satisfied a number of the criteria for selection as a surrogate substrate, the ensuing kinetics data demonstrated its impracticality. The Michaelis constant for all organisms was large (0. 0006-0.4 M) ...

75

Effect of test setup on the fiber to mortar pull out response in TRM composites: experimental and analytical modeling

Effect of test setup on the fiber to mortar pull out response in TRM composites: experimental and analytical modeling

... the pull-out response is usually performed following the shear-lag ...of pull-out problems in cementitious based matrices [28,36,37,40,41,46] and is therefore also used in this ...the ...

54

Stabilometric analysis in individuals with parkinson`s disease

Stabilometric analysis in individuals with parkinson`s disease

... Romberg test, pull test and gait examination, but all of them are quantitative methods and techniques for the measurement of postural control in geriatric assessment, whichwere not established in the ...

6

Evaluation of Tensile and Interfacial Strength of Coconut Palm Leaf Midrib as a potential Reinforcement for Plastics

Evaluation of Tensile and Interfacial Strength of Coconut Palm Leaf Midrib as a potential Reinforcement for Plastics

... fiber pull-out test [11,12,25]. In the present study single fiber pull- test is carried out for determination of interfacial bonding strength between MCL fiber and polyester resin as matrix ...

6

Application Of Value Stream Mapping In The Manufacturing Industry

Application Of Value Stream Mapping In The Manufacturing Industry

... viii i) Current Layout of Pull Test Machine 56 ii) Future Layout of Pull Test Machine 61 5.2.2.2 Summary of the Improvement Result 63 5.2.3 High Lead Time at the Cutting, Accessories Fitment, ...

24

Task Design Influences Prosociality in Captive Chimpanzees (Pan troglodytes)

Task Design Influences Prosociality in Captive Chimpanzees (Pan troglodytes)

... Although chimpanzees acted prosocially in Study 1 the rates of animals’ prosocial choices were quite modest, which starkly contrasts with the prosocial acts frequently observed in laboratory interactions between humans ...

13

The Usage of Bamboo as the Concrete Carcass Due to the Pressure and Diffraction Strength

The Usage of Bamboo as the Concrete Carcass Due to the Pressure and Diffraction Strength

... Bamboo is as one of building material but it is rarely used for construction design if it is compared with the other material [3][4]. It is due to some factors such as to be easily attacked by insect, easily to be ...

8

Predicting the Workability of Fresh Concrete Using Simple Pull-out Test

Predicting the Workability of Fresh Concrete Using Simple Pull-out Test

... the pull- out test as an alternative test for workability of fresh ...and pull-out strength for fresh concrete with water/cement ratios of ...a pull-out strength of 72 – 94N/mm 2 is ...

5

An Investigation on In-situ Strength and Bonding Strength of Polymer Modified Concretes (PMC) as Repair Overlays on Conventional Concrete Substrate

An Investigation on In-situ Strength and Bonding Strength of Polymer Modified Concretes (PMC) as Repair Overlays on Conventional Concrete Substrate

... The durability of polymer modified concrete against aggressive and corrosive environments is considerable compared to unmodified concretes [6-8]. Dogan et al. [9] have studied high performance concretes containing ...

12

Test Station for Measuring Electromechanical Relay Parameters Using Microcontroller

Test Station for Measuring Electromechanical Relay Parameters Using Microcontroller

... The Pull-in voltage and dropout voltage are measured by controlling the coil voltage through the DAC and polling the open and close status of contacts through the I/O port of ...

7

Quantitative CT-based bone strength parameters for the prediction of novel spinal implant stability using resonance frequency analysis: a cadaveric study involving experimental micro-CT and clinical multislice CT

Quantitative CT-based bone strength parameters for the prediction of novel spinal implant stability using resonance frequency analysis: a cadaveric study involving experimental micro-CT and clinical multislice CT

... Methods: Micro-CT scans before/after screw insertion ( n = 68) and MSCT scans before screw insertion ( n = 58) of human cadaveric vertebrae were assessed for conventional test forces and ISQ value. ...

10

Effect of Surface Roughness Morphology on Bond Strength of Thermal Sprayed WC-10Co-4Cr Ceramic/Metal Coating

Effect of Surface Roughness Morphology on Bond Strength of Thermal Sprayed WC-10Co-4Cr Ceramic/Metal Coating

... 3.3. Pull–off test Results of the average failure load for all samples which were performedaccording to ASTM C-633-79 standards are almost 52-55 MPa.It can be seen that maximum strength is almost similar in ...

5

A Study on Interfacial Shear Parameters of Rock Flour with Geotextile from Modified Direct Shear Box and Pull out Test

A Study on Interfacial Shear Parameters of Rock Flour with Geotextile from Modified Direct Shear Box and Pull out Test

... shear test and Pullout test are conducted using rock flour and geotextiles (woven and non-woven) to evaluate interfacial shear parameters in dry and wet ...from pull out tests are observed to be less ...

9

Testing and modelling of connections with post-installed undercut anchors under seismic loading - assessment of safety margins

Testing and modelling of connections with post-installed undercut anchors under seismic loading - assessment of safety margins

... The test setup mainly consists of a horizontally movable concrete slab on which an anchor plate is connected with four undercut anchors. The main dimensions of the setup are shown in figure 1. The component is ...

10

Test retest strength reliability of the Electronic Push/Pull Dynamometer (EPPD) in the measurement of the quadriceps and hamstring muscles on a new chair

Test retest strength reliability of the Electronic Push/Pull Dynamometer (EPPD) in the measurement of the quadriceps and hamstring muscles on a new chair

... the test and re-test peak isometric force production scores for all ...Electronic Pull/Push Dynamometer scores differed little between the knee extensors and flexors strength at 90˚ and 60˚ during ...

6

Accurate Determination of the Pull-in Voltage for MEMS Capacitive Microphone with Clamped Square Diaphragm

Accurate Determination of the Pull-in Voltage for MEMS Capacitive Microphone with Clamped Square Diaphragm

... MEMS capacitive devices have been studied by many researchers because of their superior performances, e.g. high sensitivity, low power consumption, flat frequen- cy response in wide bandwidth, low noise level, stability ...

6

A. Push and Pull Strategies

A. Push and Pull Strategies

... In a first step, basic components of a product are produced and stocked on an intermediate storage based on forecast or pre-defined schedules. As soon as a customer order is placed, the previously stocked components are ...

6

Show all 10000 documents...

Related subjects