• No results found

Rapid antigen detection test (RADT)

Spectrum Bias of a Rapid Antigen Detection Test for Group A β-Hemolytic Streptococcal Pharyngitis in a Pediatric Population

Spectrum Bias of a Rapid Antigen Detection Test for Group A β-Hemolytic Streptococcal Pharyngitis in a Pediatric Population

... the test for each stratum of Centor ...the RADT has the same specificity ( ⬍ 100%) in each Centor score stra- tum, then there will be larger differences in the sen- sitivities for the Centor score strata ...

7

Relationship Between the Clinical Likelihood of Group A Streptococcal Pharyngitis and the Sensitivity of a Rapid Antigen-Detection Test in a Pediatric Practice

Relationship Between the Clinical Likelihood of Group A Streptococcal Pharyngitis and the Sensitivity of a Rapid Antigen-Detection Test in a Pediatric Practice

... shows RADT results stratified by clinical characteristics of study ...that test sensitivity increased (P ⬍ ...in RADT sensitivity according to patient gender, year of visit, season of year, history ...

8

Performance of a Rapid Antigen-Detection Test and Throat Culture in Community Pediatric Offices: Implications for Management of Pharyngitis

Performance of a Rapid Antigen-Detection Test and Throat Culture in Community Pediatric Offices: Implications for Management of Pharyngitis

... office RADT and the office BAP culture dem- onstrated relatively low sensitivity ...The RADT, office BAP culture, and office BAP culture confirmation of negative RADT results all exhibited spectrum ...

10

DEVELOPMENT OF RAPID ANTIGEN DETECTION TEST FOR METHICILLIN RESISTANT Staphylococcus aureus INFECTION

DEVELOPMENT OF RAPID ANTIGEN DETECTION TEST FOR METHICILLIN RESISTANT Staphylococcus aureus INFECTION

... Strip preparation and cassette assembly: The sample pad, nitrocellulose membrane, and conju- gation pad were prepared, as previously desc- ribed(Huang, 2006) with modifications: The sam- ple pad (Cellulose fiber) was cut ...

7

Accuracy of a new rapid antigen detection test for pulmonary tuberculosis

Accuracy of a new rapid antigen detection test for pulmonary tuberculosis

... a rapid, accurate and cost-effective diagnostic test is a major obstacle for TB ...Pasteur rapid TB antigen detection kit (PrTBK) at Pasteur institute of Iran could give a rapid ...

5

Development of a fast and low-cost qPCR assay for diagnosis of acute gas pharyngitis

Development of a fast and low-cost qPCR assay for diagnosis of acute gas pharyngitis

... a rapid antigen detection test (RADT) to evaluate its clinical performance in 687 ...the RADT and the qPCR test were ...GAS detection. Conclusion: We showed that ...

6

Group A Streptococcus-Associated Upper Respiratory Tract Infections in a Day-Care Center

Group A Streptococcus-Associated Upper Respiratory Tract Infections in a Day-Care Center

... tococci isolated during the subsequent survey, a total of 47% of the day-care center population had positive cultures or rapid antigen detection test results (49% of children and 33% of [r] ...

7

Diagnostic Accuracy of Rapid Antigen Detection Tests for Respiratory Syncytial Virus Infection: Systematic Review and Meta analysis

Diagnostic Accuracy of Rapid Antigen Detection Tests for Respiratory Syncytial Virus Infection: Systematic Review and Meta analysis

... the test was performed nor whether or not it was done at the point of care had a significant impact on RADT ...the rapid tests were inter- preted without knowledge of the result of the reference ...

12

A Comparative Study of Rapid Immuno Chromatography Test with Elisa For Detection of Dengue Ns1 Antigen, IgM and IgG Antibody

A Comparative Study of Rapid Immuno Chromatography Test with Elisa For Detection of Dengue Ns1 Antigen, IgM and IgG Antibody

... IgG Capture ELISA is an Enzyme Linked Immunosorbent Assay for the qualitative detection of IgG antibodies against Dengue virus antigen in human serum. This kit contains a microplate, which is pre-coated ...

148

Study of clinical presentation of falciparum malaria and correlation with laboratory indices of poor prognosis

Study of clinical presentation of falciparum malaria and correlation with laboratory indices of poor prognosis

... This prospective observational study was conducted at the department of general Medicine, R N T Medical College Udaipur, India. All falciparum malarial patients, either sex, aged between 10-70 years, were selected from ...

8

Evaluation of a Novel Stool Antigen Rapid Test Kit for Detection of Helicobacter pylori Infection

Evaluation of a Novel Stool Antigen Rapid Test Kit for Detection of Helicobacter pylori Infection

... pylori antigen testing using fecal samples is adopted because of its ...fecal antigen and drug susceptibility tests can be performed using the same specimen, and the usefulness of the fecal antigen ...

6

Pneumococcal and Haemophilus influenzae Type b Antigen Detection in Children at Risk for Occult Bacteremia

Pneumococcal and Haemophilus influenzae Type b Antigen Detection in Children at Risk for Occult Bacteremia

... enzae b antigen detection using serum and/or urine is a highly sensitive and specific test for rapid diagnosis of occult bacteremia due to H influenzae. The speed (15-minute total incuba[r] ...

7

Rapid bacterial antigen detection is not clinically useful

Rapid bacterial antigen detection is not clinically useful

... bacterial antigen is a frequently performed laboratory procedure, but its use is ...this test, we reviewed all LA tests performed over a 10-month period at two sites, a major university-based referral ...

6

Evaluation of a rapid diagnostic test, NanoSign® Influenza A/B Antigen, for detection of the 2009 pandemic influenza A/H1N1 viruses

Evaluation of a rapid diagnostic test, NanoSign® Influenza A/B Antigen, for detection of the 2009 pandemic influenza A/H1N1 viruses

... To date, there are few studies on the analytical sensitiv- ity of commercialized RDT kits for detecting novel influenza viruses [9,22,23]. In this study, chicken embryos were used to culture the novel influenza A/ ...

5

Test characteristics of the SD FK80 Plasmodium falciparum/Plasmodium vivax malaria rapid diagnostic test in a non endemic setting

Test characteristics of the SD FK80 Plasmodium falciparum/Plasmodium vivax malaria rapid diagnostic test in a non endemic setting

... in test performance were presently found for samples stored for several (> 5) years compared to those stored for a shorter periods (results not ...HRP-2 antigen detection ...

8

Rapid Detection of Contagious Caprine Pleuropneumonia Using aMycoplasma capricolum subsp  capripneumoniaeCapsular Polysaccharide Specific Antigen Detection  Latex Agglutination Test

Rapid Detection of Contagious Caprine Pleuropneumonia Using aMycoplasma capricolum subsp capripneumoniaeCapsular Polysaccharide Specific Antigen Detection Latex Agglutination Test

... diagnostic test based upon the detection of carbohydrate rather than protein or DNA could offer certain advantages, since polysaccharides are the end product of multienzyme syn- thesis pathways and random ...

8

Evaluation of an immunochromatography rapid diagnosis kit for detection of chikungunya virus antigen in India, a dengue endemic country

Evaluation of an immunochromatography rapid diagnosis kit for detection of chikungunya virus antigen in India, a dengue endemic country

... The detection limit of the IC kit was determined using serially diluted CHIKV recovered from cell culture supernatants; the limit was approximately 10 4 ...of detection of the immunochromatography ...

6

African swine fever Detection on Field with Antigen Rapid Kit Test

African swine fever Detection on Field with Antigen Rapid Kit Test

... early detection of ASF, by not only veterinarians and the authorities, but also by hunters and ...field test on both WB and illegal free-ranging pigs can be a valuable tool with economic and time saving ...

8

Evaluation of novel rapid detection kits for dengue virus NS1 antigen in Dhaka, Bangladesh, in 2017

Evaluation of novel rapid detection kits for dengue virus NS1 antigen in Dhaka, Bangladesh, in 2017

... NS1 antigen detection RDT, we obtained 12 MAbs against DENV-NS1 from Bio Matrix Research, ...each test in ap- proximately 15 min (depending on humidity ...

15

Rapid Urease Test and Faecal Antigen Detection for Rapid Diagnosis of Helicobacter pylori Infection in Dyspepsia

Rapid Urease Test and Faecal Antigen Detection for Rapid Diagnosis of Helicobacter pylori Infection in Dyspepsia

... for detection of active ...faecal antigen test, serological parameters and the [13C]-urea breath test serve as surrogate markers of ...

6

Show all 10000 documents...

Related subjects