• No results found

static voltage stability limit

Improvement of Voltage Stability in Power System by Using SVC and STATCOM

Improvement of Voltage Stability in Power System by Using SVC and STATCOM

... its stability limit. Voltage instability and line overloading have become challenging problems due to the strengthening of power system by various ...of voltage stability can be ...

7

Shunt Compensation for Improvement of Voltage Stability Using Static VAR Compensator (SVC) In a Power Transmission System

Shunt Compensation for Improvement of Voltage Stability Using Static VAR Compensator (SVC) In a Power Transmission System

... Line stability index, Line stability Factor, Reduced Jacobian Determinant, Minimum Singular Value of Power Flow Jacobian, and other voltage indices ...the voltage stability limit ...

8

Stability Analysis of Power System with the Penetration of Photovoltaic Based Generation

Stability Analysis of Power System with the Penetration of Photovoltaic Based Generation

... Static voltage instability is actually related to the reactive power ...can limit loadability of that bus and hence the entire ...the limit, the system will approach to maximum loading point ...

6

Static voltage stability assessment with continuation power flow

Static voltage stability assessment with continuation power flow

... Nowadays, voltage stability is a crucial issue as the rapid increase in the load ...critical limit due to the economical and environmental constraint for preparing new power plants and transmission ...

22

LOSS MINIMIZATION AND VOLTAGE PROFILE IMPROVEMENT IN POWER SYSTEM: A REVIEW

LOSS MINIMIZATION AND VOLTAGE PROFILE IMPROVEMENT IN POWER SYSTEM: A REVIEW

... transient stability of Nigerian 330kV Transmission Network using Static VAR Compensation ...bus voltage magnitudes and phase ...tremendously, voltage profile at seven (7) buses were improved ...

19

Static Voltage Stabilizer

Static Voltage Stabilizer

... The F2806x Piccolo (Fig.3) family of microcontrollers (MCUs) provides the power of the C28x core and CLA coupled with highly integrated control peripherals in low pin count devices. This family is code-compatible with ...

5

Enhancing Power System Stability Using Static Synchronous Series Compensator (SSSC)

Enhancing Power System Stability Using Static Synchronous Series Compensator (SSSC)

... controllable voltage in the line which in turn controls the amount of real power transmitted by the network ...injected voltage (V) we can control the compensation ...injected voltage (Vqmax ...

7

ANN based SVC FACTS Controller to Enhance Voltage Stability of Multi Machine Power System

ANN based SVC FACTS Controller to Enhance Voltage Stability of Multi Machine Power System

... the voltage stability index [6][7] and Simplified Voltage stability ...Different voltage sensitivity indices are discussed in ...the voltage profile[13][14] using reactive power ...

7

A new AHP – based reactive power valuation method

A new AHP – based reactive power valuation method

... closedloop voltage control is from a few seconds and up, depending on different ...controlled static VAR compensators, because those are much cheaper and have regulating characteristics similar to ...

37

Optimal load shedding under contingency 
		conditions using voltage stability index for real time applications in 
		power systems

Optimal load shedding under contingency conditions using voltage stability index for real time applications in power systems

... A concrete approach offering the least amount and finest location of load shedding was presented in [9]. The proposed technique uses a multi-stage and non-linear approach to find the minimum load shed at each stage. ...

12

Power Quality Enhancement and Mitigation of Voltage using DPFC in Distribution Line

Power Quality Enhancement and Mitigation of Voltage using DPFC in Distribution Line

... The effective Distributed power flow controller (DPFC) [4] is derived from the Unified Power Flow Controller. It can be considered as a Unified Power Flow Controller with an eliminated common dc link. The active power ...

5

Pedagogical practice for development of coordination potential of MMA fighters and estimation of its efficiency

Pedagogical practice for development of coordination potential of MMA fighters and estimation of its efficiency

... In comparison with the data for the fighters from reference group values of common pressure center displacement speed for the fighters from experimental group in opened yes position were lower by 1.07 mm/s, while in ...

17

Improvement of Multi Machine Power System Stability Using SSSC

Improvement of Multi Machine Power System Stability Using SSSC

... the voltage magnitude, voltage across capacitor forces opposite polarity voltage across series line reactance at given line ...increasing voltage across line impedance which causes increase in ...

8

Result of Analysis of Power System Oscillation Damping & Voltage Stability Improvement Using SSSC in A Multi-Machine System

Result of Analysis of Power System Oscillation Damping & Voltage Stability Improvement Using SSSC in A Multi-Machine System

... In this condition POD is kept „off‟. Under this condition the effect on power flow at bus no. 2 is shown in fig. 3.7. The fault clears at 0.5 sec as shown in fig. 3.7. In case 2 initially Vqref is set to zero. At 2 sec. ...

7

Shuffled Frog Leaping Algorithm based Voltage Stability Limit Improvement and Loss Minimization Incorporating FACTS Devices under Stressed Conditions

Shuffled Frog Leaping Algorithm based Voltage Stability Limit Improvement and Loss Minimization Incorporating FACTS Devices under Stressed Conditions

... for voltage stability limit improvement and loss minimization are ...The voltage stability limit improvement and real power loss minimization are done under critical loading and ...

8

Optimization of Real Power Losses and Voltage Stability Limit Enhancement by Using Bacteria Foraging Algorithm P.Sreenivasulu 1, P.B.Chennaiah2 Dr. M. Suryakalavathi 3

Optimization of Real Power Losses and Voltage Stability Limit Enhancement by Using Bacteria Foraging Algorithm P.Sreenivasulu 1, P.B.Chennaiah2 Dr. M. Suryakalavathi 3

... Where F   x , u is the objective function that is real power loss of the mesh connected with multi- machine test system. g   x , u is a set of nonlinear equality constraints to represent power flow, and h   x , u ...

9

Voltage Stability Enhancement and Loss Minimization of Bus and line Static Indicators in Presence of SVC

Voltage Stability Enhancement and Loss Minimization of Bus and line Static Indicators in Presence of SVC

... It is also observed that Bus-3 has a maximum injected load 3.45p.u. Buses 15 and 30 indicate 1.60 p.u. and 0.345 p.u as the maximum permissible reactive load respectively. Further increase in the reactive power loading ...

7

Power Factor Control at ABA Control 33/11kV Injection Substation Using Auto Tuning Regulator

Power Factor Control at ABA Control 33/11kV Injection Substation Using Auto Tuning Regulator

... Agent, Static Var Compensator Agent and the co-ordination between these agents as presented in ...OLTC, Static Var Compensator (SVC) and Load ...Automatic Voltage Regulator (AVR) regulates the ...

11

Solar Integrated UPQC to Connected to the Distribution System for Power Quality improvement

Solar Integrated UPQC to Connected to the Distribution System for Power Quality improvement

... Although PV systems are emerging as power solution to meet the increased demand of electricity, but the reliability and robustness of the PV panel is always questionable. A simulation model for PV based UPQC converter is ...

8

A comprehensive comparison of facts devices for enhancing static voltage 
		stability

A comprehensive comparison of facts devices for enhancing static voltage stability

... Voltage stability is the ability of a power system to maintain voltages of power system buses after a disturbance in operating ...hand, voltage stability is the ability of power system to ...

5

Show all 10000 documents...

Related subjects