• No results found

stator turn fault detection

A New Scheme Based on Correlation Technique for Generator Stator Fault Detection-Part π

A New Scheme Based on Correlation Technique for Generator Stator Fault Detection-Part π

... generator stator besides identifying faulted phase(s) and detecting inter-turn faults in the same phase of stator ...generator stator winding internal and external faults by using both ...

7

Modelling and Wavelet Based Analysis of Stator Turn to Turn Fault in Induction Motor

Modelling and Wavelet Based Analysis of Stator Turn to Turn Fault in Induction Motor

... A wavelet based analysis [9-12] is used in this work to extract the feature from motor currents. Wavelet decomposition results in useful data contained in ‗details‘ and ‗approximate‘ parts. The ‗approximation‘ signal can ...

7

PWM Ripple Currents Based Turn Fault Detection for Multiphase Permanent Magnet Machines

PWM Ripple Currents Based Turn Fault Detection for Multiphase Permanent Magnet Machines

... circuit fault (also known as turn fault, or inter-turn fault) is one of the most severe faults ...ter-turn fault occurs, excessively high current will circulate in the ...

11

INTERN-TURN AND BEARING WEAR FAULT DETECTION IN THREE PHASE INDUCTION MOTOR MATLAB SIMULINK

INTERN-TURN AND BEARING WEAR FAULT DETECTION IN THREE PHASE INDUCTION MOTOR MATLAB SIMULINK

... This paper present simulation of three phase induction motor in Matlab for two types of incipient fault i.e., intern turn and insulation failure of the winding. The simulated result shows decrease in ...

18

Stator Fault Detection in Induction Machines by Parameter Estimation Using Adaptive Kalman Filter

Stator Fault Detection in Induction Machines by Parameter Estimation Using Adaptive Kalman Filter

... under stator faults. For instance, for increased resistance in one stator phase, the number and structure of differential equations describing the IM should clearly remains the ...the stator leaves ...

11

Modeling and Diagnosis of the Inter-Turn Short Circuit Fault for the Sensorless Input-Output Linearization Control of the PMSM

Modeling and Diagnosis of the Inter-Turn Short Circuit Fault for the Sensorless Input-Output Linearization Control of the PMSM

... circuit fault Modeling and detection for the sensorless input-output linearization control of the permanent magnet synchronous motor (PMSM) based on the Extended Kalman Filter observer ...The fault ...

10

Improving the Reliability in PMSM for Wind Turbine

Improving the Reliability in PMSM for Wind Turbine

... for fault diagnosis of a PMSM. In a fault model has been proposed for inter-turn fault of stator winding in a ...the fault model, a series of algorithms have been proposed for ...

7

Characterization of coil faults in an axial flux variable reluctance PM motor

Characterization of coil faults in an axial flux variable reluctance PM motor

... single stator coil may have relatively little effect on motor perfor- mance but may affect overall motor reliability, availability, and ...These fault characterization and analysis results are a necessary ...

9

DEVELOPMENT OF MODEL FOR STATOR WINDING INTER-TURN FAULT IN PERMANENT MAGNET SYNCHRONOUS MOTOR

DEVELOPMENT OF MODEL FOR STATOR WINDING INTER-TURN FAULT IN PERMANENT MAGNET SYNCHRONOUS MOTOR

... early fault detection and diagnosis helps in reducing the machine wear and tear, machine down time and maintenance ...different fault detection techniques have been applied for electric motors ...

12

Internal Fault Detection, Location, and Classification in Stator Winding of the Synchronous Generators Based on the Terminal Voltage Waveform

Internal Fault Detection, Location, and Classification in Stator Winding of the Synchronous Generators Based on the Terminal Voltage Waveform

... single turn-turn ones), other methods had been proposed to achieve this goal by considering a model for the stator ...These fault models suppose that the ratio between the winding inductances ...

10

Bispectrum of stator phase current for fault detection of induction motor

Bispectrum of stator phase current for fault detection of induction motor

... Healthy 1.5766 0.9170 0.9577 0.8795 40.0879 5 Turn Short 0.9104 0.6554 0.9934 0.8370 40.2341 10 Turn Short 0.5640 0.4944 0.9671 0.8297 40.1754 15 Turn Short 0.3046 0.2896 0.9473 0.8534 40.0233 Broken ...

15

A New Scheme Based on Correlation Technique for Generator Stator Fault Detection-Part І

A New Scheme Based on Correlation Technique for Generator Stator Fault Detection-Part І

... to stator earth and phase faults, inter-turn faults, unbalanced stator currents, overheating, overvoltage, undervoltage, loss-of-excitation, over excitation, over speed, generator motoring, rotor ...

9

Induction Machine Stator Inter-Turn Short Circuit Fault Detection using Discrete Wavelet Transform

Induction Machine Stator Inter-Turn Short Circuit Fault Detection using Discrete Wavelet Transform

... 5% stator turn short and for 10% stator turn short, the %tage variations are ...5% stator turn short and for 10% stator turn short, these the %tage variations are ...

8

Fault detection in three phase induction motor using artificial intelligence

Fault detection in three phase induction motor using artificial intelligence

... to stator defects will set up an axial homopolar flux in the shaft, which can be sensed by a search coil fitted around the ...of stator ir drop and approximately independent of motor leakage reactance ...

24

Stator Turn-to-Turn Fault Detection of Induction Motor by Non-Invasive Method Using Generalized Regression Neural Network

Stator Turn-to-Turn Fault Detection of Induction Motor by Non-Invasive Method Using Generalized Regression Neural Network

... Therefore, in this research, GRNN is used in the design of fault diagnosis system and non-invasive criterion, i.e. negative sequence current is considered as efficient indi- cators of stator fault. ...

12

STATOR TURN-TO-TURN FAULT DETECTION OF SYNCHRONOUS GENERATOR USING TOTAL HARMONIC DISTORTION (THD) ANALYZING OF MAGNETIC FLUX LINKAGE

STATOR TURN-TO-TURN FAULT DETECTION OF SYNCHRONOUS GENERATOR USING TOTAL HARMONIC DISTORTION (THD) ANALYZING OF MAGNETIC FLUX LINKAGE

... of fault diagnosis system in transverse flux motor that is presented in Table ...possible fault modes ...the fault to the magnetic flux signals. Hence, as a recent trend, fault monitoring of ...

22

1. Comparison Of Interturn and Turn to turn fault in Transformer By SFRA Method

1. Comparison Of Interturn and Turn to turn fault in Transformer By SFRA Method

... the fault in the transformer ...inter turn fault and turn to turn fault Hence different fault could be simulated in MATLAB by SFRA ...

6

Healthy Monitoring and Fault Detection Outer Race Bearing in Induction Motor Using Stator Current

Healthy Monitoring and Fault Detection Outer Race Bearing in Induction Motor Using Stator Current

... damage detection study using noise but in practice it did not show accurate results because there were other disturbing noise ...the stator core, so that the motor operation must be stopped, and the small ...

13

Analysis of Dynamic Behaviour of a DFIG Based Wind Turbine during Symmetrical Three Phase Fault at Grid End Using Crowbar Protection

Analysis of Dynamic Behaviour of a DFIG Based Wind Turbine during Symmetrical Three Phase Fault at Grid End Using Crowbar Protection

... As electrical power demand is increasing day-by-day, new generating units must be installed to the grid. Renewable energy resources are connected to grid because this form of energy is pollution free. Among all the ...

8

Turn turn short circuit fault management in permanent magnet machines

Turn turn short circuit fault management in permanent magnet machines

... From Table IV, it can be seen that there is a slight difference in both the resistance and the inductances of the vertical conductor wound machine with respect to conventional round conductor wound machine. This is ...

24

Show all 10000 documents...