• No results found

Thoracostomy tube

Necessity of routine thoracostomy tube insertion after transhiatal esophagectomy

Necessity of routine thoracostomy tube insertion after transhiatal esophagectomy

... chest tube. There was no statistically relation between chest tube insertion and hospital mortality ...of thoracostomy tube output was more than 400 ml in 3 (75%) ...chest tube drainage ...

5

Ultrasound-guided thoracostomy site identification in healthy volunteers

Ultrasound-guided thoracostomy site identification in healthy volunteers

... that tube thoracostomy became common in the treatment of injured patients ...point, thoracostomy tube placement became a mandatory skill for all providers taking care of trauma ...from ...

5

Infant and Young Child Feeding Practices among the Mothers in Urban Slums of Dibrugarh Town: A Cross Sectional Study

Infant and Young Child Feeding Practices among the Mothers in Urban Slums of Dibrugarh Town: A Cross Sectional Study

... Chest tube placement, under radiologic guidance, is the least invasive and most common non-surgical modality for ...Optimal thoracostomy tube size has been a controversial topic amongst chest ...

6

Primary spontaneous hemopneumothorax: A meta-analysis study

Primary spontaneous hemopneumothorax: A meta-analysis study

... of thoracostomy tube drainage; it is reported that initial drainage even in large amount is not necessarily an indication for operation provided that patient being stable and replaced well [11, ...

6

In Dogs With Pyothorax Does Medical Management Alone, Invasive Medical Management, or Surgical Management Result in Better Long term Outcome?

In Dogs With Pyothorax Does Medical Management Alone, Invasive Medical Management, or Surgical Management Result in Better Long term Outcome?

... a thoracostomy tube (invasive medical, 26) with or without pleural lavage and heparin, or a thoracotomy (surgical, 13) and thoracostomy tube with or without pleural lavage and ...

14

Oesophageal Perforation: A diagnostic and therapeutic challenge in a resource limited setting. A report of three cases

Oesophageal Perforation: A diagnostic and therapeutic challenge in a resource limited setting. A report of three cases

... Following the methylene blue swallow the patient was observed for 2 days and there was no leakage into the thoracostomy tube, fever or cough. At this time (1 month) after the perforation oesophageal healing ...

5

Management for Pediatric Pleural Empyema in Resource Poor Country: Is Chest Tube Drainage with Antiseptic Lavage Irrigation Better than Tube Thoracostomy Alone?

Management for Pediatric Pleural Empyema in Resource Poor Country: Is Chest Tube Drainage with Antiseptic Lavage Irrigation Better than Tube Thoracostomy Alone?

... Meta analysis comparing operative and non-operative procedures has concluded that conservative manage- ment leads to recovery in more than 76% of the patients [22]. However, it needs to be emphasised that a less in- ...

8

Therapy of Parapneumonic Effusions in Children: Video-Assisted Thoracoscopic Surgery Versus Conventional Thoracostomy Drainage

Therapy of Parapneumonic Effusions in Children: Video-Assisted Thoracoscopic Surgery Versus Conventional Thoracostomy Drainage

... conventional thoracostomy arm (see Fig 1) had chest tube placement within 24 hours of effusion ...the thoracostomy tube was left in place until it drained ⬍ 1 mL/kg per day for ⬎ 24 ...chest ...

9

A case report of thoracic compartment syndrome in the setting of penetrating chest trauma and review of the literature

A case report of thoracic compartment syndrome in the setting of penetrating chest trauma and review of the literature

... right thoracostomy tube was placed, which returned 800 mL of ...mL thoracostomy output and hemodynamic stabi- lity), therefore planning the workup for potential surgi- cal sources of bleeding ...

5

The Frequency of Reexpansion Pulmonary Edema after Trocar and Hemostat Assisted Thoracostomy in Patients with Spontaneous Pneumothorax

The Frequency of Reexpansion Pulmonary Edema after Trocar and Hemostat Assisted Thoracostomy in Patients with Spontaneous Pneumothorax

... der to exclude decompression pressure variation by diame- ter of pleural opening. Nevertheless, the opening of the pleura might be bigger in hemostat technique because the opening of the pleura was made manually prior to ...

6

Study on Computer Generated Electromagnetic Effects on Computer Users

Study on Computer Generated Electromagnetic Effects on Computer Users

... [4] Jiangfeng Guo, Lin Cheng, Mingtian Xu ,Optimization design of shell-and-tube heat exchanger by entropy genera- tion minimization and genetic algorithm Applied Thermal Engineering, Volume 29, Issue 14 (2009) ...

5

RECITAL SCRUTINY ON TUBE-IN- TUBE COMPACT HEAT EXCHANGERS

RECITAL SCRUTINY ON TUBE-IN- TUBE COMPACT HEAT EXCHANGERS

... This paper focused on the investigational cram of the recital characteristics of tube-in-tube compact heat exchangers. Experiments are conducted in the compact heat exchangers with R-134a and liquefied ...

6

Influence of flowing fluid property through an elastic tube on various deformations along the tube length

Influence of flowing fluid property through an elastic tube on various deformations along the tube length

... elastic tube (320 mm in length, 20 mm inner diameter, 1 mm thickness), is mounted between the two aluminum pipes with a slight axial extension to avoid the longitudinal bending especially when the tube ...

31

Optimization of Shell and Tube Heat Exchanger for Tube Arrangements

Optimization of Shell and Tube Heat Exchanger for Tube Arrangements

... and tube heat exchanger is the most common type heat exchanger widely used in oil refinery and other large chemical process, because it suits high pressure ...and tube heat exchanger and optimize the shell ...

5

A Review on Experimental Investigation of U-Tube Heat Exchanger using Plain Tube and Corrugated Tube

A Review on Experimental Investigation of U-Tube Heat Exchanger using Plain Tube and Corrugated Tube

... The current project is focus on to reduce pressure drop at shell side and at u-tubes side as well as to increase heat transfer rate. This can be done in UTHX using plain tube and corrugated tube. In ...

5

Experimental Investigation of U tube heat exchanger using Plain tube and Corrugated tube

Experimental Investigation of U tube heat exchanger using Plain tube and Corrugated tube

... Gulsah Cakmak had been used U-tube heat exchanger for water heating storage. Water was used as heat transfer fluid and calcium-chloride hexa-hydrate with 29 °C melting temperature was used. In U-tube bundle ...

6

Evaluation of performance of two different chest tubes with either a sharp or a blunt tip for thoracostomy in 100 human cadavers

Evaluation of performance of two different chest tubes with either a sharp or a blunt tip for thoracostomy in 100 human cadavers

... In 2009, the National Patient Safety Agency in the Uni- ted Kingdom reported that equipment problems, ade- quate training, and site selection are crucial factors influencing effective and safe chest drain insertion [20]. ...

6

Enhancing the Heat Transfer Parameters in Double Pipe Heat Exchanger by Creating Turbulence in Inner and Outer Tube

Enhancing the Heat Transfer Parameters in Double Pipe Heat Exchanger by Creating Turbulence in Inner and Outer Tube

... Plain tube, Corrugated tube, Plain tube with helically twisted wire and Plain tube with twisted clip ...Concentric tube heat ...

6

Comparison of a novel, endoscopic chest tube insertion technique versus the standard, open technique performed by novice users in a human cadaver model: a randomized, crossover, assessor-blinded study

Comparison of a novel, endoscopic chest tube insertion technique versus the standard, open technique performed by novice users in a human cadaver model: a randomized, crossover, assessor-blinded study

... chest tube is subsequently inserted through the trocar [4, ...Nevertheless, tube thor- acostomy using a trocar-type device or the Reactor™ has not yet been compared with the standard, open ...of tube ...

9

Creep Life Assessment of Primary Reformer HP40-NB Modified Steel Tube of an Ammonia Plant

Creep Life Assessment of Primary Reformer HP40-NB Modified Steel Tube of an Ammonia Plant

... reformer tube was performed, wherein the experimental Larson–Miller diagram and area fraction of creep voids were ...the tube in service was metallographically analyzed by using light and electron ...

8

Show all 4207 documents...

Related subjects