• No results found

Total Harmonics Distortion

TOTAL HARMONICS DISTORTION REDUCED BY USING STATCOM

TOTAL HARMONICS DISTORTION REDUCED BY USING STATCOM

... the total harmonics ...the total harmonics distortion as the STATCOM provide compensation it is shunt connected FACTS controller power electronic based or IGBT basesd device which ...

5

Integration of Smart Grids and PV System Total Harmonics Distortion (THD) Reduction

Integration of Smart Grids and PV System Total Harmonics Distortion (THD) Reduction

... In the new era the smart grid plays an important role as the network is automated and monitored using the modern IT/communication/ control technology [4]. Those electronic automated equipment has negative effects on the ...

9

Average Current Mode Control Technique Applied To Boost Converter For Power Factor Improvement And Thd Reduction

Average Current Mode Control Technique Applied To Boost Converter For Power Factor Improvement And Thd Reduction

... Power factor has a high impact on power system industries. A load with low power factor draws more current than a load with high power factor for the same amount of useful power transferred. The high current increases ...

9

Fault Detection and Analysis of Three Phase Induction Motors using MATLAB Simulink Model

Fault Detection and Analysis of Three Phase Induction Motors using MATLAB Simulink Model

... For analysis of fault condition typical methodology of quick Fourier transform area unit initial use and take a look at for various winding fault conditions. Then fuzzy logic controller supported fuzzy rule base style ...

7

MODELING OF DSTATCOM USING NON LINEAR LOAD

MODELING OF DSTATCOM USING NON LINEAR LOAD

... of harmonics and compensate reactive power in Power ...low harmonics distortion, reduced number of switches, suppression of switching losses and take out the Total Harmonics ...

9

Harmonics Distortion Analysis of Multipulse Converter
                 

Harmonics Distortion Analysis of Multipulse Converter  

... There are two types of conversion techniques , one is uncontrolled in which diodes are implemented and other is controlled in which thyristors are implemented respectively [8].The performance improvement is achieved for ...

5

Harmonic reduction of a single phase multilevel inverter using genetic algorithm and particle swarm optimization

Harmonic reduction of a single phase multilevel inverter using genetic algorithm and particle swarm optimization

... reduce total harmonics distortion, modulation technique and switching ...of total harmonics distortion and voltage boosting ...both total harmonics ...

52

Implementation and Analysis of Cascaded H Bridge Multilevel Inverter Using Space Vector PWM

Implementation and Analysis of Cascaded H Bridge Multilevel Inverter Using Space Vector PWM

... In this modulation the signal is generated by injecting harmonics to the sine wave. The result is a flat topped wave form and it reduces the amount of over modulation. A higher fundamental amplitude and low ...

12

Calculating Total Harmonic Distortion by Measuring Sine Wave

Calculating Total Harmonic Distortion by Measuring Sine Wave

... Harmonic distortion may be measured by applying a spectrally clean sine wave voltage signal to the input of the amplifier under ...fourth harmonics, ...

6

Performance Optimization of Pi Controller in Three Phase Shunt Hybrid Filter Using PSO

Performance Optimization of Pi Controller in Three Phase Shunt Hybrid Filter Using PSO

... ABSTRACT : This paper attempts to tune the PI parameters in the implementation on shunt hybrid filterby using ameta heuristic optimising technique like PSO.Total Harmonic Distortion is taken as the objective ...

9

Background voltage distortion and percentage of nonlinear load impacts on the harmonics produced by a group of personal computers

Background voltage distortion and percentage of nonlinear load impacts on the harmonics produced by a group of personal computers

... voltage distortion, decrease in Power Factor (PF), system resonance, equipment failure, impact energy metering, thermal effects on rotating machines, increase system losses, malfunction of electronic devices and ...

5

Grid-friendly Active Demand Strategy on Air Conditioning Class Load

Grid-friendly Active Demand Strategy on Air Conditioning Class Load

... Figure 9 is voltage waveform monitored from DC bus of the energy storage interface and current waveform of the grid side. The left are voltage waveforms happened at the time of nonlinear group load normal operation, LVRT ...

13

Simulation and Comparison of Twenty Five Level Diode Clamped & Cascaded H-Bridge Multilevel Inverter

Simulation and Comparison of Twenty Five Level Diode Clamped & Cascaded H-Bridge Multilevel Inverter

... of total twenty four dc voltage sources, V1R – V24R for R-phase, V1Y – V24Y for Y-phase, V1B-V24B for ...equal. Total 48 Power switch (IGBT) is used per phase, for three phase total 144 ...becomes ...

11

A Methodology for Low-Cost Optimization of Energy Efficient Passive Filters in Distribution Networks

A Methodology for Low-Cost Optimization of Energy Efficient Passive Filters in Distribution Networks

... Different researchers have studied the proper limitation of harmonic disturbance levels, and among several techniques used to reduce these harmonic disturbances, the most frequently employed are the passive filters, due ...

10

Performance analysis 
		of active power filter for harmonic compensation using PI PSO

Performance analysis of active power filter for harmonic compensation using PI PSO

... In recent years the world has witnessed an increase in the use of non-linear loads. These loads draw harmonic non-sinusoidal currents and voltages in the connection point with the utility and distribute them through it. ...

7

A Novel Energy Management Software Using NI LabVIEW

A Novel Energy Management Software Using NI LabVIEW

... Energy saving data input section: This section is very important section of the software. This section will give an exhaustive details of energy saving and management details. This section has four inputs: Improved ...

6

Controlled Rectifier with Improved Dynamic Response for Under Unbalanced Supply and Variable Line and Load Inductances

Controlled Rectifier with Improved Dynamic Response for Under Unbalanced Supply and Variable Line and Load Inductances

... voltage harmonics causing distortion of load waveform, voltage fluctuation, voltage dip, heating of equipment ...current harmonics in power ...of harmonics we have to compensate the harmonic ...

15

Enhancement of THD in HVDC System using Shunt Active Power Filters

Enhancement of THD in HVDC System using Shunt Active Power Filters

... This class of filters constitutes the most important and widely used filter configuration in industrial process. It is connected in parallel to the main power circuit as shown in Fig.2.1. The concept of the shunt active ...

7

Simulation Of A 3-, 2-Level Inverter With A Discrete 3- Pwm Generator To Reduce The Harmonics And Improve The Power Quality

Simulation Of A 3-, 2-Level Inverter With A Discrete 3- Pwm Generator To Reduce The Harmonics And Improve The Power Quality

... Distortion of harmonics in power/force appropriation system can be stifled utilizing 2 methodologies in particular, latent/passive and dynamic/active fueling. The passive type of sifting/filter is the least ...

9

Total Harmonic Distortion Minimization of Multilevel Converters Using Genetic Algorithms

Total Harmonic Distortion Minimization of Multilevel Converters Using Genetic Algorithms

... Among The topologies for high power multilevel in- verters, the cascaded inverter has the advantages that the DC-link voltage is balanced, the modularized circuit lay- out is possible, and it has the least components per ...

5

Show all 10000 documents...

Related subjects