• No results found

X-ray Phase Shift and Phase Contrast

Effects of Tube Voltage on Phase Contrast Imaging for Different Microfocus X Ray Tubes

Effects of Tube Voltage on Phase Contrast Imaging for Different Microfocus X Ray Tubes

... Keywords: Phase-Contrast Imaging; Edge Enhancement; X-Ray; Tube Voltage ...Conventional x-ray imaging is based on the attenuation properties of an object, however, for some weak ...

5

Edge illumination x-ray phase contrast CT

Edge illumination x-ray phase contrast CT

... the phase and absorption (analyser) gratings are placed downstream of the object, a significant fraction of radiation that delivers dose to the object does not contribute to the image formation ...the phase ...

217

Sensitivity of edge illumination X-ray phase-contrast imaging

Sensitivity of edge illumination X-ray phase-contrast imaging

... edge phase-based signal has been extended here to the case of EI XPCi, a technique currently under intensive development at ...the phase shift and to a function of the illumination curve and its first ...

9

X-ray phase contrast imaging: From synchrotrons to conventional sources

X-ray phase contrast imaging: From synchrotrons to conventional sources

... the vertical direction, and to extend sufficiently to cover the full extent of the object in the horizontal one. The detector consists of a single row of pixels, as large as the beam in the horizontal direction. As often ...

42

Phase-contrast X-ray imaging with synchrotron radiation for materials science applications

Phase-contrast X-ray imaging with synchrotron radiation for materials science applications

... the phase con- trast achieved depends on a derivative (first or second) of the phase shift u, and are particularly appropriate to studies which benefit from edge enhancement, ...of phase and ...

9

Inclusion of coherence in Monte Carlo models for simulation of x-ray phase contrast imaging

Inclusion of coherence in Monte Carlo models for simulation of x-ray phase contrast imaging

... the phase grating, the self image is ...the phase shift induced by the object can be ...keV X-ray beam. Both the phase and the absorption grating have a pitch of m and a 50% ...

10

Optimization and new applications of edge-illumination based X-ray phase contrast CT

Optimization and new applications of edge-illumination based X-ray phase contrast CT

... the phase shift directly however is not possible, since X-ray detectors are sensitive to changes in X-ray ...a phase contrast image, the imaging system must be able ...

170

Geometric correction method for 3d in-line X-ray phase contrast image reconstruction

Geometric correction method for 3d in-line X-ray phase contrast image reconstruction

... of X-ray phase contrast imaging (XPCI) components causes projection data misplaced, and thus result in the reconstructed slice images of computed tomography (CT) blurred or with edge ...a ...

11

3D Cardiac microvessels embolization imaging based on X-ray phase contrast imaging

3D Cardiac microvessels embolization imaging based on X-ray phase contrast imaging

... by X-ray phase contrast ...[17]. Contrast and resolution are derived from direct Fresnel diffraction with synchrotron radiation which has good spatial co- herence and high ...object, ...

9

Single-shot X-ray phase-contrast computed tomography with non-microfocal laboratory sources

Single-shot X-ray phase-contrast computed tomography with non-microfocal laboratory sources

... to shift the argument of the illumination curve by −Δx ¼ −k −1 z 2 ∇ x ϕ, where z 2 is the propagation distance between the sample and the detector mask, and Δx is the spatial shift of the beam along ...

6

The effect of the spatial sampling rate on quantitative phase information extracted from planar and tomographic edge illumination x-ray phase contrast images

The effect of the spatial sampling rate on quantitative phase information extracted from planar and tomographic edge illumination x-ray phase contrast images

... The lower optimal sampling rate in tomographic com- pared to planar EI XPCi can be understood intuitively. In planar EI XPCi, a low sampling rate is not sufficient since not all parts of the sample are illuminated by the ...

9

X-ray phase-contrast imaging

X-ray phase-contrast imaging

... Abstract X-ray imaging is a standard tool for the non-destructive inspection of the in- ternal structure of ...the X-rays traversing the sample are subjected to different amount of absorption in ...

43

Contrast detail phantoms for X-ray phase-contrast mammography and tomography

Contrast detail phantoms for X-ray phase-contrast mammography and tomography

... low- contrast details of different size on images obtained at conventional mammog- raphy unit, and at a monochromatic synchrotron radiation source, in absorp- tion based and phase contrast imaging ...

8

Quantitative edge illumination x-ray phase contrast tomography

Quantitative edge illumination x-ray phase contrast tomography

... Two sets of experiments have been performed to validate the theory: one with a “single slit” EI XPCi setup at a synchrotron, and one with a “multi slit” setup implemented entirely with commercial x-ray ...

11

Contributions to the characterization of grating-based x-ray phase-contrast imaging

Contributions to the characterization of grating-based x-ray phase-contrast imaging

... different contrast channels obtainable by grating- based imaging were investigated and ...the phase ϕ and the amplitude a 1 of the phase-stepping oscillation are described by a wrapped Gaussian PDF ...

153

Low-dose phase contrast tomography with conventional x-ray sources

Low-dose phase contrast tomography with conventional x-ray sources

... commercial x-ray source with an ex- tended nonmicrofocal spot and a polychromatic ...the phase shifting proper- ties of an object provided a higher SDNR than attenuation ...

6

Tilted-grating approach for scanning-mode X-ray phase contrast imaging

Tilted-grating approach for scanning-mode X-ray phase contrast imaging

... existent X-ray phase-contrast modalities, grating interferometry appears as a very promising technique for commercial applications, since it is compatible with conventional X-ray ...

13

X-ray phase contrast tomography; proof of principle for post-mortem imaging

X-ray phase contrast tomography; proof of principle for post-mortem imaging

... Conventional X-ray CT is quicker, easier to use and more widely available; however, it suffers from poor soft-tissue differentiation, especially in foetuses and children, in the absence of exogenous ...

6

Low temperature electroplating for highly conformal x-ray phase contrast gratings

Low temperature electroplating for highly conformal x-ray phase contrast gratings

... in contrast, only one half of the samples had plastic deformation regions, all others showed brittle behav- ...the phase contrast imaging process that temperature (induced by radiation) can deform ...

147

X-ray Phase-Contrast Tomography: Underlying Physics and Developments for Breast Imaging

X-ray Phase-Contrast Tomography: Underlying Physics and Developments for Breast Imaging

... high contrast sensitivity and spatial resolution in the order of 10 µm, while scan times range from hours to tens of ...and X-ray flux since the source size projected at the sample position is ...

168

Show all 10000 documents...

Related subjects