• No results found

[PDF] Top 20 Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing

Has 10000 "Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing" found on our website. Below are the top 20 most common "Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing".

Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing

Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing

... all screws in the same perfect central screw placement, it is possible that drilling and inserting the screw may result in a small degree of tilt that might cause the nail and screw to interlock, in turn cause ... See full document

7

Functional Outcome of Expert Tibial Intramedulary Nailing for Metaphyseal Distal One Third Fractures of Tibia

Functional Outcome of Expert Tibial Intramedulary Nailing for Metaphyseal Distal One Third Fractures of Tibia

... an intramedullary nailing system is indicated not only for distal third tibia fractures but also for proximal third fractures of tibia and fractures of shaft of ...routine ... See full document

5

Intramedullary nailing versus plating for distal tibia fractures without articular involvement: a meta-analysis

Intramedullary nailing versus plating for distal tibia fractures without articular involvement: a meta-analysis

... fibular fracture fix- ation. Locking and nonlocking plates were combined into one meta-analysis group and then compared with IM nail- ...among locking and nonlocking plates ...analyze locking ... See full document

12

Evaluating Outcome of Distal Tibia and Fibula Fractures Treated with Intra Medullary Nailing

Evaluating Outcome of Distal Tibia and Fibula Fractures Treated with Intra Medullary Nailing

... the distal of subchondral plate and then intramedullary canal was established using ...two distal locking screw was performed using intramedullary guide wire and then proximal ... See full document

6

Results of Dynamic Interlock Nailing in Distal Tibial Fractures

Results of Dynamic Interlock Nailing in Distal Tibial Fractures

... and intramedullary nailing in dynamic mode on union, implant failure and incidence of malalignment in patients who sustained an extra-articular fracture of the distal ...of distal ... See full document

10

A Comparative study on the Functional Outcome in the Management of Extra Articular Distal Femur Fractures by Retrograde Intramedullary Interlocking Nailing Vs Distal Femoral Locking Plate

A Comparative study on the Functional Outcome in the Management of Extra Articular Distal Femur Fractures by Retrograde Intramedullary Interlocking Nailing Vs Distal Femoral Locking Plate

... tibial nailing, hence the ability to fix a floating knee with minimal dissection) ...the distal femoral ...the distal fragment in both the AP and lateral ...the distal fragment by passage of ... See full document

109

Extra-articular proximal tibia fracture: minimally invasive plate osteosynthesis or intramedullary nailing - a comparative study

Extra-articular proximal tibia fracture: minimally invasive plate osteosynthesis or intramedullary nailing - a comparative study

... Comparative studies between IMN and MIPPO for extra- articular proximal tibial fractures are very limited. In our study, the average age of patients was between 38.6 years as compared to Sean Nork et al 9 : 42 years, ... See full document

6

Periprosthetic femoral fracture fixation: A biomechanical comparison between proximal locking screws and cables

Periprosthetic femoral fracture fixation: A biomechanical comparison between proximal locking screws and cables

... mm distal to the lesser trochanter, with an additional gauge positioned on the lateral side of the femur, 200 mm distal to the lesser ...and distal bony ... See full document

16

The use of tibial Less Invasive Stabilization System (LISS) plate [AO-ASIF] for the treatment of paediatric supracondylar fracture of femur: a case report

The use of tibial Less Invasive Stabilization System (LISS) plate [AO-ASIF] for the treatment of paediatric supracondylar fracture of femur: a case report

... the fracture was displaced and the boy was quite big for his ...flexible intramedullary nails was not a good choice as it is diffi- cult to control the alignment when there was comminu- ...small ... See full document

6

Comparison of Proximal Femur Locking Compression Plate and Intramedullary Nailing in the Treatment of Sub-Trochanteric Fractures

Comparison of Proximal Femur Locking Compression Plate and Intramedullary Nailing in the Treatment of Sub-Trochanteric Fractures

... ST fracture and Group B included patients using in- tramedullary nailing to treat their ST ...proximal screws were fitted to fix the ...five screws to the ...standard intramedullary ... See full document

7

Use of Poller Screws in Proximal and Distal Metaphyseal Fractures of Tibia: A Prospective study

Use of Poller Screws in Proximal and Distal Metaphyseal Fractures of Tibia: A Prospective study

... Open reduction and plate fixation is also associated with a high incidence of soft tissue complications in the range of 10 to 15% in many sereis 8 . But the recent advances in plating techniques and designing have ... See full document

88

A Comparison of Locking Versus Non-Locking Plates in Distal Femur Fractures

A Comparison of Locking Versus Non-Locking Plates in Distal Femur Fractures

... the locking plate the screw head has threads which lock into the plate, and the combination of screws and plate create a stable construct for comminuted and osteo- porotic ...fractures. Biomechanical ... See full document

5

A comparison of the cost effectiveness of intramedullary nail fixation and locking plate fixation in the treatment of adult patients with an extra articular fracture of the distal tibia

A comparison of the cost effectiveness of intramedullary nail fixation and locking plate fixation in the treatment of adult patients with an extra articular fracture of the distal tibia

... A comparison of the cost-effectiveness of intramedullary nail fixation and locking plate fixation in the treatment of adult patients with an extra-articular fracture of the distal ... See full document

29

Fatigue strength of common tibial intramedullary nail distal locking screws

Fatigue strength of common tibial intramedullary nail distal locking screws

... comminuted fracture that was treated by IM nailing assuming that all load was carried by the ...simulated screws placed in the distal region of an appropriately sized tibial IM ...screw ... See full document

7

Functional outcome of extrarticular  distal tibia fractures treated by Intramedullary nailing

Functional outcome of extrarticular distal tibia fractures treated by Intramedullary nailing

... a biomechanical study in 2002 on consequences of treating distal tibia fractures with modified tibial nails by cutting their distal ...4cm distal tibial fragments stabilised with ... See full document

116

Site-Specific Radiation Exposure during Intramedullary
Nails: A Comparison between the Free-Hand Technique
and the Electromagnetic Assisted Technique

Site-Specific Radiation Exposure during Intramedullary Nails: A Comparison between the Free-Hand Technique and the Electromagnetic Assisted Technique

... Technique: Fracture reduction and implant insertion was performed with the patient under general or regional anesthesia in a standard fashion according to the guidelines given by the ...the distal ... See full document

5

Modification of elastic stable intramedullary nailing with a 3rd nail in a femoral spiral fracture model – results of biomechanical testing and a prospective clinical study

Modification of elastic stable intramedullary nailing with a 3rd nail in a femoral spiral fracture model – results of biomechanical testing and a prospective clinical study

... this biomechanical model the 3rd nail from antero- lateral ‘ 3CL ’ was effective in reducing two of the three causes of poor clinical outcomes in ESIN-osteosynthesis: the danger of shortening (significantly higher ... See full document

10

Trochanteric Buttress Plate Combined with Proximal Femoral Nail for Unstable Intertrochanteric Fractures  [Innovative Technique]

Trochanteric Buttress Plate Combined with Proximal Femoral Nail for Unstable Intertrochanteric Fractures [Innovative Technique]

... of screws may be this protrusion is most likely because of the shearing force caused by the tendency for a lateral displacement of the proximal end and a medial displace- ment of the distal end in unstable ... See full document

13

Improving stability of elastic stable intramedullary nailing in a transverse midshaft femur fracture model: biomechanical analysis of using end caps or a third nail

Improving stability of elastic stable intramedullary nailing in a transverse midshaft femur fracture model: biomechanical analysis of using end caps or a third nail

... stable intramedullary nailing (ESIN osteosynth- esis) for displaced paediatric femoral fractures in child- hood has gained wide acceptance [7, 29], and even older children and sometimes adolescents are ... See full document

8

Distal radius fracture   outcome with volar locking compression plate

Distal radius fracture outcome with volar locking compression plate

... unstable distal radius fractures treated between July 2013 and August 2014 at the Department of Orthopaedics, and approved by Institutional Ethics committee for Human SSG Hospital, Vadodara, Gujarat, ... See full document

5

Show all 10000 documents...