• No results found

[PDF] Top 20 Cyclic out-of-plane shear behaviour of sc composite structures

Has 10000 "Cyclic out-of-plane shear behaviour of sc composite structures" found on our website. Below are the top 20 most common "Cyclic out-of-plane shear behaviour of sc composite structures".

Cyclic out-of-plane shear behaviour of sc composite structures

Cyclic out-of-plane shear behaviour of sc composite structures

... plant structures are designed withstand seismic loads that would subject the structure into cyclic load ...the cyclic behavior and ductility of SC design for out-of-plane ...high ... See full document

10

An experimental study of the in-plane cyclic behavior of steel-plate composite walls with boundary elements

An experimental study of the in-plane cyclic behavior of steel-plate composite walls with boundary elements

... Steel-plate composite (SC) walls are being constructed in nuclear power plants (NPPs) in the United States and ...provide out-of-plane shear reinforcement, and shear studs that ... See full document

9

A comparison of the shear behaviour of a fibre composite sandwich structure in the transverse and in-plane directions

A comparison of the shear behaviour of a fibre composite sandwich structure in the transverse and in-plane directions

... beam shear test creates a pure shear for composite sandwich structures at the location of maximum ...the shear strain is pure, both ten- sile and compressive strains should be equal and ... See full document

6

Experimental and numerical studies of combined in-plane and out-of-plane behavior of sc wall piers

Experimental and numerical studies of combined in-plane and out-of-plane behavior of sc wall piers

... rectangular SC wall specimens were built and tested under force-controlled monotonic OOP loading and displacement-control cyclic IP ...of SC composite shear walls; the effects become ... See full document

10

Experimental Study on Mechanical Behaviour of Composite Beam Using SCC with Shear Connectors

Experimental Study on Mechanical Behaviour of Composite Beam Using SCC with Shear Connectors

... engineering structures depends upon the materials and increasing load carrying ...sandwich composite structures was increased in many countries but curing process and erection process is very ... See full document

6

Behaviour of fibre composite sandwich structures under short and asymmetrical beam shear tests

Behaviour of fibre composite sandwich structures under short and asymmetrical beam shear tests

... Fibre composite sandwich structures are being increasingly used in applications requiring high bending stiffness and strength, combined with low ...Sandwich structures generally consist of face ... See full document

33

Development of a shear test to determine the cyclic behaviour of sheet materials

Development of a shear test to determine the cyclic behaviour of sheet materials

... simple shear tests have been developed: the one-sided shear test and the symmetrical shear ...one-sided shear test is the most basic way to perform a shear test in which the two clamped ... See full document

154

Behavior of fiber reinforced steel concrete systems under hazard loads

Behavior of fiber reinforced steel concrete systems under hazard loads

... the behaviour of large-scale steel-plate composite (SC) walls subjected to displacement-controlled cyclic lateral loading representative of seismic ...rectangular SC wall specimens with ... See full document

9

Experimental Behaviour of Flexure Critical Steel-Plate Composite SC Shear Walls

Experimental Behaviour of Flexure Critical Steel-Plate Composite SC Shear Walls

... rectangular SC wall specimens (SC1 through SC4) with an aspect ratio of ...displacement-controlled cyclic loading in the NEES laboratory at the University at ... See full document

10

Lateral Load Behaviour and Capacity of Structures Consisting of SC Walls

Lateral Load Behaviour and Capacity of Structures Consisting of SC Walls

... applied shear force increases beyond the point of steel yield, the condition of equilibrium on the composite shell element can no longer occur since the steel plates are no longer able to resist additional ... See full document

10

Study On Modeling Out-of-plane Behavior Of SC Walls Using Shell Elements

Study On Modeling Out-of-plane Behavior Of SC Walls Using Shell Elements

... of SC shear wall and wall panel tests using finite element method were conducted previously by the authors and were presented in detail Sener et ...unreinforced SC beam specimens using solid elements ... See full document

10

AN EXPERIMENTAL STUDY OF THE IN-PLANE CYCLIC BEHAVIOR OF LOW ASPECT RATIO SC WALL PIERS

AN EXPERIMENTAL STUDY OF THE IN-PLANE CYCLIC BEHAVIOR OF LOW ASPECT RATIO SC WALL PIERS

... (SC) composite walls are being constructed in nuclear power plants (NPPs) in the United States and ...provide out-of-plane shear reinforcement, and shear studs that enable ... See full document

10

On the interaction of in-plane and out-of-plane demands for steel-plate composite (sc) walls

On the interaction of in-plane and out-of-plane demands for steel-plate composite (sc) walls

... of SC wall piers is different than that of labyrinthine SC ...the SC walls (with flanges) resist the in-plane flexure through the flanges, and in-plane shear through the web; ... See full document

11

Behavior and Modeling of SC Composite Structures Under Out-of-Plane Shear Loading

Behavior and Modeling of SC Composite Structures Under Out-of-Plane Shear Loading

... Steel-concrete composite (SC) walls of safety-related nuclear facilities are subjected primarily to in-plane shear forces and gravity ...to out-of plane shear and bending ... See full document

10

Effects of Out-of-Plane Shear Force on the In-Plane Behaviour of SC Walls

Effects of Out-of-Plane Shear Force on the In-Plane Behaviour of SC Walls

... the SC wall pier behaviour and numerical evaluations discussed above, a test matrix for the experimental investigations is developed and is presented in Table ...are shear critical ...the ... See full document

10

Shear Transfer Mechanism in FRP Reinforced Composite Concrete Structures

Shear Transfer Mechanism in FRP Reinforced Composite Concrete Structures

... The specimens were ready to test after about twenty-eight days of curing at which the desired strength of approximately 35 MPa was achieved. After painting each specimen with white paint, it was placed horizontally in ... See full document

110

Static in plane shear behaviour of prefabricated wood wool panel wallettes

Static in plane shear behaviour of prefabricated wood wool panel wallettes

... The application of WWCP as a building material has been introduced since 1920’s, however, the application of this panel limited to non-structural application such as wall partition, ceiling, insulation, acoustic and ... See full document

9

Discrete element modelling of the in-plane and out-of-plane behaviour of dry-joint masonry wall constructions

Discrete element modelling of the in-plane and out-of-plane behaviour of dry-joint masonry wall constructions

... mechanical behaviour of such structures depends on the quality and strength of the connections between elements of the structure including partition walls, internal load-bearing partitions, floors and roof ... See full document

34

Identification of Out-of-Plane Material Characteristics through Sheet-Metal Blanking

Identification of Out-of-Plane Material Characteristics through Sheet-Metal Blanking

... the out-of-plane direction is proposed. The in-plane procedures from uniaxial tensile testing are implemented in the out- of-plane blanking experiments to determine shear yield ... See full document

10

Seismic Behaviour of Infilled Frame Structures with and Without Shear Wall

Seismic Behaviour of Infilled Frame Structures with and Without Shear Wall

... concrete shear walls are used in bare frame building to resist lateral force due to wind and ...utilities. Shear wall provide lateral load resisting by transferring the wind or earthquake load to ...with ... See full document

9

Show all 10000 documents...