• No results found

[PDF] Top 20 The Design and Optimization of the Heat Exchanger of the Sea Water Source Heat Pump Air Conditioning System Based on the Baffle Spacing

Has 10000 "The Design and Optimization of the Heat Exchanger of the Sea Water Source Heat Pump Air Conditioning System Based on the Baffle Spacing" found on our website. Below are the top 20 most common "The Design and Optimization of the Heat Exchanger of the Sea Water Source Heat Pump Air Conditioning System Based on the Baffle Spacing".

The Design and Optimization of the Heat Exchanger of the Sea Water Source Heat Pump Air Conditioning System Based on the Baffle Spacing

The Design and Optimization of the Heat Exchanger of the Sea Water Source Heat Pump Air Conditioning System Based on the Baffle Spacing

... the sea water source heat pump system [1] uses sea water to provide cooling and heat sources for ships to exchange heat in the heat ... See full document

5

SHELL & TUBE HEAT EXCHANGER THERMAL DESIGN WITH OPTIMIZATION OF MASS FLOW RATE AND BAFFLE SPACING

SHELL & TUBE HEAT EXCHANGER THERMAL DESIGN WITH OPTIMIZATION OF MASS FLOW RATE AND BAFFLE SPACING

... tube heat exchangers (STHXs) from the economic ...shell-and-tube heat exchanger as the design variables and the genetic algorithm is applied to solve the associated optimization ...the ... See full document

6

A REVIEW ON SHELL AND TUBE HEAT EXCHANGER USING VARIOUS DESIGN ARRANGEMENT OF BAFFLE

A REVIEW ON SHELL AND TUBE HEAT EXCHANGER USING VARIOUS DESIGN ARRANGEMENT OF BAFFLE

... Three design variables such as shell internal diameter, outer tube diameter and baffle spacing are considered for ...for heat exchanger ... See full document

5

Optimization of a Residential Air Source Heat Pump using Heat Exchangers with Small Diameter Tubes

Optimization of a Residential Air Source Heat Pump using Heat Exchangers with Small Diameter Tubes

... ABSTRACT Heat exchangers play significant role in refrigeration and air conditioning ...the system performance while reducing the size, weight and cost of the heat ...lower ... See full document

10

Surface Water Source Heat Pump Air Conditioning System Simulation and Operation Performance Analysis

Surface Water Source Heat Pump Air Conditioning System Simulation and Operation Performance Analysis

... the heat pump system can be conducted on the basis of a relatively simple calculation ...of heat pump simulation models have been developed, these models can be approximately divided ... See full document

7

Performance Assessment of a Variable Capacity Air Source Heat Pump and a Horizontal Loop Coupled Ground Source Heat Pump System

Performance Assessment of a Variable Capacity Air Source Heat Pump and a Horizontal Loop Coupled Ground Source Heat Pump System

... Hot water was dumped daily in accordance with the IEA Schedule Task 26 model for a typical Canadian family of four people (Safa, ...30) based on climate normals derived from a 30-year historical record of ... See full document

9

Space Heating And Air Conditioning with Heat Exchanger Under Groundwater

Space Heating And Air Conditioning with Heat Exchanger Under Groundwater

... a heat pump when providing heating, not only to have a low heating distribution temperature but also to have as high a source temperature as ...for air source heat pumps because ... See full document

39

Investigation on thermal-hydraulic performance of outdoor heat exchanger in air sources heat pump

Investigation on thermal-hydraulic performance of outdoor heat exchanger in air sources heat pump

... micro-channel heat exchangers [27-32], but little information exists on the study of folded louvered fin tube heat exchanger under frosting ...fin-tube heat exchanger can perform well ... See full document

29

1.
													Vibration analysis of shell and tube heat exchanger by changing baffle spacing using chemcad

1. Vibration analysis of shell and tube heat exchanger by changing baffle spacing using chemcad

... in heat exchangers when the intensity increases to the point that it causes some part of the exchanger to fail mechanically, upsets the process conditions, or creates a condition that endangers those who ... See full document

5

Application Research on the Closed-loop Heat-source-Tower Heat Pump Air Conditioning System in Hot-summer and Cold-winter Zone

Application Research on the Closed-loop Heat-source-Tower Heat Pump Air Conditioning System in Hot-summer and Cold-winter Zone

... conventional air conditioning heat and cold source schemes usually set respectively cold sources (refrigerator) and heat source ...problems, air conditioning ... See full document

8

Efficiency of Mini Type Shell Heat Exchanger For Car Air Conditioning System

Efficiency of Mini Type Shell Heat Exchanger For Car Air Conditioning System

... shell heat exchanger for car air conditioning ...type heat exchanger and automotive industry ...the heat exchanger need to be ...Wira’s air ... See full document

24

Development of Air-to-air Heat Pump Simulation Program with Advanced Heat Exchanger Circuitry Algorithm

Development of Air-to-air Heat Pump Simulation Program with Advanced Heat Exchanger Circuitry Algorithm

... 2.2.2. Newton Raphson Method Besides the successive substitution method, the Newton-Raphson method is also used for system simulations. Mullen et al. (1998) developed the ACRC solver that uses the Newton-Raphson ... See full document

259

Study of Micro Channel Heat Exchanger for Automotive Heat Pump System

Study of Micro Channel Heat Exchanger for Automotive Heat Pump System

... residential air-conditioner is modified to apply to the automotive heat pump ...tube-pass design of our MC-HEX (FMC) for the outdoor unit of a residential air-conditioner gives priority ... See full document

11

Optimization of a Geothermal Heat Pump System with Aboveground Water Storage

Optimization of a Geothermal Heat Pump System with Aboveground Water Storage

... ventilation air, which would substantially reduce the overall building ...the air source heat pump was frequently observed in the defrost ...This heat pump function was ... See full document

102

FLOW AND HEAT TRANSFER CHARACTERISTICS OF AIR IN SQUARE CHANNEL HEAT EXCHANGER WITH C-SHAPED BAFFLE: A NUMERICAL STUDY

FLOW AND HEAT TRANSFER CHARACTERISTICS OF AIR IN SQUARE CHANNEL HEAT EXCHANGER WITH C-SHAPED BAFFLE: A NUMERICAL STUDY

... the heat transfer rate and thermal performance in various types of heat exchangers or engineering devices had been done by two methods; active and passive ...augment heat transfer ...for heat ... See full document

18

Exergy of heat flows of the air to air plate heat exchanger

Exergy of heat flows of the air to air plate heat exchanger

... of heat flows in the heat ...the heat loss exer- gy ∆E accounts for the biggest ...the heat loss exergy ∆E depend on the temperature gra- dient ∆t i,e1 = T i – T e , but it is also influenced by ... See full document

6

Research Article Modeling of an Air Conditioning System with Geothermal Heat Pump for a Residential Building

Research Article Modeling of an Air Conditioning System with Geothermal Heat Pump for a Residential Building

... the heat pump unit and the connection with the ground, specially drilling, but the operating costs are lower than conventional systems because of their high ...GSHP system may not be the cheapest ... See full document

6

Study on Air source Heat Pump Heating System Based on Photovoltaic Generation Complementary with Grid

Study on Air source Heat Pump Heating System Based on Photovoltaic Generation Complementary with Grid

... Air-source heat pump heating system based on photovoltaic generation complementary with grid is proposed in this ...the system to replace the photovoltaic array. The ... See full document

5

Wall Mounted Mini-Split System Air Conditioning/Heat Pump Service Manual

Wall Mounted Mini-Split System Air Conditioning/Heat Pump Service Manual

... the pump to operate until the system has been evacuated down to 300 ...the pump to continue running for an additional 15 minutes. Turn off the pump and leave the connections secured to the two ... See full document

69

Heat Exchanger Design

Heat Exchanger Design

... The TEMA-F - shell design provides for a longitudinal flow plate to be installed inside the tube bundle assembly. This plate causes the shell fluid to travel down one half of the tube bundle, then down the other ... See full document

32

Show all 10000 documents...