Development and validation of a virtual reality transrectal ultrasound guided prostatic biopsy simulator
... the simulator is composed of a TRUS biopsy probe, a 3D magnetic tracking system, a mock pelvis and a biopsy activator foot pedal ...simulated biopsy within the mock pelvis ...our biopsy ... See full document
8
Virtual reality, ultrasound guided liver biopsy simulator: Development and performance discrimination
... medical virtual reality simulators, with some validated to show improved clinical skills, ...no simulator has met this standard [5, 6, 10], with validation studies typically failing to ... See full document
8
Validation of a Simulator Set Up Entirely in an Academic Setting: Low-Cost Surgical Trainer Rather than High-Cost Videogame
... Over the past several decades, surgical learning has been based on three different models: the traditional triad “see one, do one, teach one”, the cadaveric model and the animal one. According to the first method, the ... See full document
10
Caudal Block for Digital-guided Transrectal Prostate Biopsy
... The mean VAS in our study was 1.2±1.6 SD, this is similar to 1.49 ± 1.93 SD found by Ikuerowo et al among 34 patients randomised to receive caudal block for tranrectal prostate biopsy [5]. However Sahin et al in a ... See full document
5
Multiparametric magnetic resonance imaging transrectal ultrasoundguided cognitive fusion biopsy of the prostate: Clinically significant cancer detection rates stratified by the Prostate Imaging and Data Reporting System version 2 assessment categories
... TRUS guided biopsy in PI-RADSv2 category 4 and 5 lesions compared to rates of cancer detection reported in the literature using either in-bore or automated MRI-TRUS fusion systems, particularly in ... See full document
13
Transrectal ultrasound guided biopsy for prostate cancer detection: Systematic and/or magnetic resonance imaging targeted
... negative biopsy. In this study, we compared 12-core systematic biopsy (SYS), MRI-targeted biopsy (TAR), and the asso- ciation of systematic and MRI-targeted (SYS+TAR) prostate biopsy in ... See full document
8
Role of Transrectal Sonography with Colour Doppler and MRI in Evaluation of Prostatic Lesions with TRUS Guided Biopsy Correlation.
... Although prostate cannot be directly visualized by conventional methods, Intravenous urography and cystourethrography can show the prostatic impression in the floor of the urinary bladder. The urethra may be ... See full document
91
Clinical importance of the antibiotic regimen in transrectal ultrasound-guided biopsy: quinolone versus cephalosporin
... Until innovative new technology can replace the TRUS- PBx in the future, this procedure will be performed several million times every year worldwide to diagnose prostate cancer. Several prevention strategies to reduce ... See full document
6
An augmented reality simulator for ultrasound guided needle placement training
... the simulator by the public, radiological community and regulating bodies, it must be demonstrated that skills developed on the simulator are transferable to the clinical setting (transfer of training) and ... See full document
18
How valid are commercially available medical simulators?
... level of validity for the simulators was also determined by searching public scientific databases. Quite possibly, manu- facturers have performed validity tests with a small group of experts, but refrained from ... See full document
11
Multiparametric MRI to improve detection of prostate cancer compared with transrectal ultrasound-guided prostate biopsy alone: the PROMIS study.
... TRUS-guided biopsy, performs poorly as a diagnostic test for CS prostate ...to biopsy in all men with an elevated serum PSA level then one-quarter of men might safely avoid a biopsy, thus ... See full document
214
On road virtual reality driving simulator
... the virtual car window even though the participant is sitting straight ...the virtual representa- tion and the real situation can induce severe visual-vestibular conflicts that can lead to simulator ... See full document
48
Role of information in preparing men for transrectal ultrasound guided prostate biopsy: a qualitative study embedded in the ProtecT trial
... undergo biopsy [29] and this information will need adapting for men deciding whether to initiate PSA ...(MRI) guided biopsy are be- coming increasing common and will have a different pro- file of ... See full document
9
Multiparametric MRI to improve detection of prostate cancer compared with transrectal ultrasound-guided prostate biopsy alone : the PROMIS study
... TRUS-guided biopsy and TPM- biopsy as measured by sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) using the primary definition of CS ... See full document
215
Acute Prostatitis After Transrectal Ultrasound-guided Prostate Biopsy: Comparing Two Different Antibiotic Prophylaxis Regimen
... All patients were provided with informed consent before the biopsy and all personal informations reserved private. According to multiple studies Povodine Iodine would decrease infection rate sufficiently and ... See full document
5
Local anesthesia for pain control during transrectal ultrasound-guided prostate biopsy: a systematic review and meta-analysis
... The limitations of this meta-analysis mainly generated from the heterogeneity of study designs, including racial and age differences, numbers of core biopsies, caliber and shape of the ultrasound probes, and ... See full document
10
Development of a Virtual Reality Cycling Simulator
... bicycle simulator with a motion platform which simulates physical forces and the ...our simulator has Mestre et ...of virtual reality in sportive ...the virtual scene (Mestre, ... See full document
13
Rates and Determinants of Complications Following Trans-Rectal Prostate Biopsy in Enugu, Nigeria
... For prostate volume (PV) and AUR, 7 of the 8 patients (75%) with AUR in our series had PV >160mls and this was statistically significant (χ 2 =24.3, p<0.00002). This finding is in agreement with that of earlier ... See full document
8
Efficacy of Serum Prostate Specific Antigen (PSA), Digital Rectal Examination (DRE) and 12-core Transrectal ultrasound (TRUS) guided biopsy in detecting Carcinoma Prostate
... of biopsy detectable clinically significant disease The results were comparable to our study in that no DRE positive patients had a serum PSA values less than ...a transrectal biopsy only after ... See full document
9
Strategies for prevention of ultrasound-guided prostate biopsy infections
... cal considerations may have hindered its more widespread utilization. This includes the need for general or spinal anes- thetic, although some reports of local anesthesia have been reported. Also, the increased technical ... See full document
9