• No results found

[PDF] Top 20 Distal radius fractures with diaphyseal involvement: fixation with fixed angle volar plate

Has 10000 "Distal radius fractures with diaphyseal involvement: fixation with fixed angle volar plate" found on our website. Below are the top 20 most common "Distal radius fractures with diaphyseal involvement: fixation with fixed angle volar plate".

Distal radius fractures with diaphyseal involvement: fixation with fixed angle volar plate

Distal radius fractures with diaphyseal involvement: fixation with fixed angle volar plate

... in fractures with major joint ...for fractures of the distal radius in adults, superior functional and radiological results of ORIF with respect to external fixation have been reported ... See full document

7

Mid-term functional outcome after the internal fixation of distal radius fractures

Mid-term functional outcome after the internal fixation of distal radius fractures

... standard volar approach through the bed of Flexor Carpi Radialis was ...Smartlock volar locking plate (Stryker Leibinger GmbH & ...titanium plate incorporating 20 degree variable ... See full document

8

Original Article Efficacy of volar locking plate fixation for unstable distal radius fractures in elderly patients

Original Article Efficacy of volar locking plate fixation for unstable distal radius fractures in elderly patients

... by volar fixed-angle plate fixation than those by cast immobilization [21], because unsatisfac- tory radiographic outcome in older patients did not necessarily translate into ... See full document

7

Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes

Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes

... Locking volar plates mechanically bridge the bone and bear the load through the locking construct, resulting in a lower incidence of ...of distal screws is essential to prevent a loss of correction and to ... See full document

8

External fixation versus volar locking plate for displaced intra-articular distal radius fractures: a prospective randomized comparative study of the functional outcomes

External fixation versus volar locking plate for displaced intra-articular distal radius fractures: a prospective randomized comparative study of the functional outcomes

... internal fixation include direct visualization and manipulation of the frac- ture fragments, stable rigid fixation, and the possibility of immediate postoperative ...motion. Fixed-angle ... See full document

6

Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius : randomised controlled trial

Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius : randomised controlled trial

... wire fixation: wires are passed through the skin over the dorsal aspect of the distal radius and into the bone to hold the fracture in the correct anatomical ...Locking plate fixation: ... See full document

11

Short term comparative study of external fixation versus volar locking compression plate in the treatment of unstable distal radius fractures

Short term comparative study of external fixation versus volar locking compression plate in the treatment of unstable distal radius fractures

... The original plates had round holes. If compression was needed for the fracture, a separate device was needed to accomplish this. The Dynamic Compression Plate (Fig.9) (DCP was introduced in 1969 and was the ... See full document

72

Incidence of complications and secondary procedure following distal radius fractures treated by volar locking plate (VLP)

Incidence of complications and secondary procedure following distal radius fractures treated by volar locking plate (VLP)

... the distal radius, which is the central axis of the loading on the wrist joint ...B distal radius fractures fixed by VLP, with a signifi- cant lunate fossa collapse in 21 cases ... See full document

9

Original Article Results of type C fractures of distal radius treated by volar locking plate (VLP), an observational comparative study

Original Article Results of type C fractures of distal radius treated by volar locking plate (VLP), an observational comparative study

... is fixed first which allows readjustment according to status of articular ...the distal locking penetrating beyond the dosal ...and fixation, the prona- tor quadratus is repaired with absorbable su- ... See full document

9

Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate

Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate

... a volar approach is easier than a dorsal approach and the reduction of the volar cortex is simple because of less comminution and the advantage of direct vision ...a volar locking plate ... See full document

6

Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial.

Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial.

... locking plate fixation, the locking plate is applied through an incision over the volar (palm) aspect of the ...of plate, and the number and configuration of screws were decided by the ... See full document

10

Distal radius fracture   outcome with volar locking compression plate

Distal radius fracture outcome with volar locking compression plate

... this plate enables early joint mobilization with stable fixation construct owing to its close forming near articular margin and availability of different screw directions; proving its biomechanical ...of ... See full document

5

Volar locking plate versus external fixation with optional additional K-wire for treatment of AO type C2/C3 fractures: a retrospective comparative study

Volar locking plate versus external fixation with optional additional K-wire for treatment of AO type C2/C3 fractures: a retrospective comparative study

... The fixed-angle and locking screw/ hole allowed securing the small fragments and provided better ...unstable distal radius frac- tures [26, ... See full document

8

Volar locking distal radius plates show better short-term results than other treatment options: a prospective randomised controlled trial

Volar locking distal radius plates show better short-term results than other treatment options: a prospective randomised controlled trial

... of distal radius fractures and although information on as many variables as possible was recorded, it proved difficult to ensure that baseline data was ... See full document

9

Evaluation of Functional results of distal end radius fractures managed by ligamentotaxis with or without percutaneous   K -wire augmentation

Evaluation of Functional results of distal end radius fractures managed by ligamentotaxis with or without percutaneous K -wire augmentation

... in distal end radius can be attributed to an over whelming large proportion of male patients and high outdoor activities and the female population largely work indoors ... See full document

11

Short Term Functional Outcome Analysis of Internal Fixation of Distal Ulna Fractures with Concomitant Distal Radius Fractures

Short Term Functional Outcome Analysis of Internal Fixation of Distal Ulna Fractures with Concomitant Distal Radius Fractures

... internal fixation techniques, which take advantage of this superior ...the radius has a somewhat trapezoidal ...the radius, which makes capture difficult from a dorsal ...the radius at this ... See full document

96

Original Article Comparison of open reduction volar locking plate fixation and closed reduction percutaneous K-wire fixation in the treatment of AO type C1 distal radius fractures

Original Article Comparison of open reduction volar locking plate fixation and closed reduction percutaneous K-wire fixation in the treatment of AO type C1 distal radius fractures

... unstable fractures [1, 3, ...of distal radial fractures, which include the use of percutaneous K-wire fixation, exter- nal fixation and open reduction internal fixation with ... See full document

6

Treatment of neglected mal:union: of the distal radius: a cases series study

Treatment of neglected mal:union: of the distal radius: a cases series study

... Malunited fractures of the distal radius with volar angulation Corrective osteotomy in 6 cases using the volar approach.. Nalbantoglu U, Gereli A, Ucar Y, Turkmen M.[r] ... See full document

5

Meta-analysis for dorsally displaced distal radius fracture fixation: volar locking plate versus percutaneous Kirschner wires

Meta-analysis for dorsally displaced distal radius fracture fixation: volar locking plate versus percutaneous Kirschner wires

... the pins may also loosen, with the possibility of causing tendon irritation or attritional rupture of tendons, as well as causing irritation of the superficial branch of the radial nerve. These complications could lead ... See full document

12

Volar locking plates not touching the flexor pollicis longus tendon appear as prominences on radiographs: a cadaver study

Volar locking plates not touching the flexor pollicis longus tendon appear as prominences on radiographs: a cadaver study

... thus distal placement of the plate is a factor for higher Soong ...and volar place- ment of the implant were risk factors for tendon attrition after VLP ... See full document

7