[PDF] Top 20 Functional and radiological outcome of posterior plate osteosynthesis for displaced tibial plateau fractures
Has 10000 "Functional and radiological outcome of posterior plate osteosynthesis for displaced tibial plateau fractures" found on our website. Below are the top 20 most common "Functional and radiological outcome of posterior plate osteosynthesis for displaced tibial plateau fractures".
Functional and radiological outcome of posterior plate osteosynthesis for displaced tibial plateau fractures
... Tibial plateau fractures, one of the commonest intra articular fractures, occurring as a result of RTA, fall from height, violence ...these fractures has always been in debate because ... See full document
117
Functional and radiological evaluations of high-energy tibial plateau fractures treated with double-buttress plate fixation
... the posterior border of the tibia. Another plate was inserted through an interval created between the medial head of the gastrocnemius and the pes anserinus tendons, and was positioned at the lower portion ... See full document
6
Clinical and radiological outcome following treatment of displaced lateral clavicle fractures using a locking compression plate with lateral extension: a prospective study
... clavicle fractures new perspectives for the so far frustrating surgical therapy have ...clavicle plate leads to sufficient stabilization and good functional out- come with high patient satisfaction ... See full document
9
Comparison of outcome of unilateral locking plate and dual plating in the treatment of bicondylar tibial plateau fractures
... or functional outcome between the three groups in our ...locking plate can reduce the discomfort of hardware impingement ...locking plate reduces the soft tissue dissection, operation time, ... See full document
9
A Compartive analysis of functional outcome of tibial plateau fractures treated with proximal tibial locking plate with raft screw technique and conventional buttress plating
... cm posterior to the posteromedial edge of the tibial ...the posterior aspect of the tibia, and ...compression plate was contoured and fixed with screws in distal ...3.5-mm plate acting ... See full document
134
Functional Outcome Analysis of bicolumn plating in bicondylar tibial plateau fractures
... cm posterior to the posteromedial edge of the tibial ...the posterior aspect of the tibia, and ...compression plate was contoured and fixed with screws in distal ...3.5-mm plate acting ... See full document
96
Functional Outcome of Locking Compression Plating for Closed Schatzker Type V and Type VI Tibial Plateau Fractures: A Prospective study
... Forty year old male, presented to casualty following a road traffic accident, in a state of hemodynamic shock. He was revived with emergency blood transfusion and supportive measures. Primary survey revealed that he had ... See full document
108
Functional and Radiological outcome of Distal third Tibia fractures managed by Minimally invasive plate Osteosynthesis: A Prospective study
... for osteosynthesis and directly relates to the outcome of distal tibial fractures ...of fractures of the tibial plafond has been well ... See full document
113
A Prospective study of functional outcome of bicondylar tibial plateau fracture managed with locking compression plate
... and displaced fragments or larger articular depression usually heals with a valgus alignment and hence have a great risk of osteoarthritis due to uneven joint ...condyle fractures, even with minimal ... See full document
147
A study on functional and radiological outcome of complex tibial plateau fractures by posteromedial plating
... advent of arthroscope and pre-op MRI the incidence can still go high. The diagnosis is usually made during the surgery or arthroscopic examination. Meniscal injuries are not serious enough in relation to the osseous ... See full document
115
A prospective study of functional outcome of displaced middle third clavicular fractures treated by plate osteosynthesis.
... third displaced (Robinson type 2b1 and 2b2) clavicular fractures are treated with ...Reconstruction plate, Locking compression plate and 1/3 rd tubular plate for ...primary ... See full document
115
Functional and radiological outcome of Proximal tibial fractures type V and Type VI treated by modified hybrid external fixator
... All fractures (19 out of 20) united in an average time of 18 weeks (16- 25 ...open fractures and type VI tibial plateau fractures ... See full document
122
Functional and radiological outcome of fractures of dorso lumbar spine treated by short segment posterior stabilisation with intermediate screws.
... segment posterior stabilisation with intermediate screws provides better biomechanical stability when compared with conventional short segment ...better outcome especially in fractures involving the ... See full document
136
Why tibial plateau fractures are overlooked
... Conclusions: The major reasons for overlooking TPFs were 1) difficulty in recognizing the fractures on X-rays and 2) that X-ray decision rules were not employed. Two thirds of the patients, for whom a radiograph ... See full document
6
Fractures of both bones forearm: A Comparative study on fixation techniques and functional outcome between intramedullary nailing and plate osteosynthesis
... fixing fractures of radius involving distal 3 rd shaft, the titanium elastic nail did not provide with adequate stability of fracture fragments because of wide medullary ... See full document
120
Comparative analysis of functional outcome of intercondylar fracture distal humerus by plate osteosynthesis using trap approach and other posterior approaches
... of fractures of the distal humerus remained unpredictable until improved techniques for the fixation of small, articular fractures as developed by the AO (Arbeitsgemeinschaft f ür Osteosynthesefragen) or ... See full document
97
Comparison of radiological and functional outcome in patients with fracture shaft of humerus treated with interlocking nailing and with plate osteosynthesis: A Prospective study
... OF RADIOLOGICAL AND FUNCTIONAL OUTCOME IN PATIENTS WITH FRACTURE SHAFT OF HUMERUS TREATED WITH INTERLOCKING NAILING AND WITH PLATE OSTEOSYNTHESIS is a Bonafide work done by me at ... See full document
113
Outcome Analysis for Closed Intraarticular Displaced Calcaneal Fractures with Calcaneal Locking Plate.
... locking plate with 15 locking holes allows for fixation of different fracture pattern, with mouldable superior and inferior arms which provide support for anterior processes and plantar ...The plate is ... See full document
111
Functional Outcome of various modalities of management of Distal Tibial Fractures
... “FUNCTIONAL OUTCOME OF VARIOUS MODALITIES OF MANAGEMENT OF DISTAL TIBIAL FRACTURES” under my guidance and supervision in partial fulfillment of the regulations laid down by The Tamil Nadu ... See full document
92
Analysis of functional outcome of anterolateral plating in tibial pilon fractures
... Locking compression plating (LCP) is the most widely used implant for tibial pilon fractures at present. It can be performed by minimally invasive technique or standard open reduction and internal fixation ... See full document
140
Related subjects