• No results found

[PDF] Top 20 FUZZY MODELLING OF LIQUID DESICCANT BASED AIR DEHUMIDIFICATION SYSTEM

Has 10000 "FUZZY MODELLING OF LIQUID DESICCANT BASED AIR DEHUMIDIFICATION SYSTEM" found on our website. Below are the top 20 most common "FUZZY MODELLING OF LIQUID DESICCANT BASED AIR DEHUMIDIFICATION SYSTEM".

FUZZY MODELLING OF LIQUID DESICCANT BASED AIR DEHUMIDIFICATION SYSTEM

FUZZY MODELLING OF LIQUID DESICCANT BASED AIR DEHUMIDIFICATION SYSTEM

... compression air conditioning system and Integrated fuzzy model was also developed for vapor compression air conditioning system ...the fuzzy self-tuning proportional ... See full document

11

An experimental investigation of a micro tubular SOFC membrane separated liquid desiccant dehumidification and cooling tri generation system

An experimental investigation of a micro tubular SOFC membrane separated liquid desiccant dehumidification and cooling tri generation system

... delivers liquid from a tank situated at the bottom of the rig to the membrane mass/heat exchangers at the top of the ...the dehumidification circuit, a pump (D Pump) delivers strong desiccant ... See full document

18

Experimental study of a membrane based dehumidification cooling system

Experimental study of a membrane based dehumidification cooling system

... environmental-friendly air conditioning approaches without the shortcomings of overcooling and reheating 1 ...solid desiccant system, the liquid desiccant system is more ... See full document

10

An investigation of heat and mass transfer enhancement of air dehumidification with addition of Ξ³-Al2O3 nano-particles to liquid desiccant

An investigation of heat and mass transfer enhancement of air dehumidification with addition of Ξ³-Al2O3 nano-particles to liquid desiccant

... the liquid desiccant and the air, in surface vapor pressure, is driving force for mass transfer ...studied liquid desiccant ...of liquid desiccant and develop new ... See full document

18

Parametric analysis of a cross flow membrane based parallel plate liquid desiccant dehumidification system: numerical and experimental data

Parametric analysis of a cross flow membrane based parallel plate liquid desiccant dehumidification system: numerical and experimental data

... units π‘π‘‡π‘ˆ, solution to air mass flow rate ratio π‘šβˆ—, solution temperature π‘‡π‘ π‘œπ‘™ , solution.. concentration πΆπ‘ π‘œπ‘™ , inlet air temperature π‘‡π‘Žπ‘–π‘Ÿ,𝑖𝑛 and relative humidity π‘…π»π‘Žπ‘–π‘Ÿ,𝑖𝑛.[r] ... See full document

32

Theoretical analysis of a membrane based cross flow liquid desiccant system

Theoretical analysis of a membrane based cross flow liquid desiccant system

... Abstract: Liquid desiccant air dehumidification has become one of the most widely used dehumidification technologies with advantages of high efficiency, no liquid condensate ... See full document

8

Performance assessment of a membrane liquid desiccant dehumidification cooling system based on experimental investigations

Performance assessment of a membrane liquid desiccant dehumidification cooling system based on experimental investigations

... membrane-based liquid desiccant dehumidification (MLDD) system is adopted, which involves an indirect contact process for ...of liquid desiccant solution into the supply ... See full document

38

Overview Of Liquid Desiccant Based Indirect Evaporative Cooling System

Overview Of Liquid Desiccant Based Indirect Evaporative Cooling System

... higher desiccant flow rate, moisture removal rate decreases as desiccant solution temperature increases but moisture removal rate increases with increasing desiccant solution concentration also with ... See full document

7

Experimental Study on the Performance of Cross Flow Regenerator in Liquid Desiccant Cooling System

Experimental Study on the Performance of Cross Flow Regenerator in Liquid Desiccant Cooling System

... a liquid desiccant (triethylene glycol) and air in a packed bed absorption tower using high liquid flow ...of dehumidification, as well as the effectiveness of the ... See full document

9

A Review on Desiccant Dehumidification Assisted Air Conditioning System

A Review on Desiccant Dehumidification Assisted Air Conditioning System

... The desiccant assisted evaporative cooling is sustainable, economical and cleaner space cooling technique possibly the better option over traditional vapor-compression system based conventional ... See full document

5

A Novel Type-2 Adaptive Neuro Fuzzy Inference System Classifier for Modelling Uncertainty in Prediction of Air Pollution Disaster (RESEARCH NOTE)

A Novel Type-2 Adaptive Neuro Fuzzy Inference System Classifier for Modelling Uncertainty in Prediction of Air Pollution Disaster (RESEARCH NOTE)

... A fuzzy based air quality index (FAQI) method for air quality valuation has proposed by Sowlat et ...a fuzzy based algorithm based on Mamadani inference engine with one ... See full document

6

Control system for obtaining water from 
		air dehumidification by Peltier cells

Control system for obtaining water from air dehumidification by Peltier cells

... The dehumidification system is made mainly by two walls of 4 Peltier cells located face to face, they bring in their cold faces the condensation surface as shown in Figure ... See full document

7

State of art in modelling methods of membrane based liquid desiccant heat and mass exchanger: a comprehensive review

State of art in modelling methods of membrane based liquid desiccant heat and mass exchanger: a comprehensive review

... conjugate heat and mass transfer for counter and cross hollow fiber membrane modules.. Schematics of the membrane tube bank with in-line and staggered.[r] ... See full document

60

VENTILATION SYSTEM WITH GROUND HEAT EXCHANGER

VENTILATION SYSTEM WITH GROUND HEAT EXCHANGER

... The air collected by the air intake (Fig. 8) goes to ground air heat ...cold air is ...ventilation air after the data direc- tory of manufacturers and well-known literature sources to ... See full document

10

Experimental Study Of Counter Flow Air Dehumidifier For Different Packing Heights

Experimental Study Of Counter Flow Air Dehumidifier For Different Packing Heights

... the desiccant solution ...The system is allowed to run for some time till the steady state condition is ...The desiccant enters at the top of the dehumidifier and the liquid distributer tray ... See full document

8

The Effect of Absorber Packing Height on the Performance of a Hybrid Liquid Desiccant System

The Effect of Absorber Packing Height on the Performance of a Hybrid Liquid Desiccant System

... of air volumes and liquid desiccant flowrates experience an improved coefficient of performance compared with the vapour compression unit alone, as shown in ...both air patterns (mixed or ... See full document

10

Energy Performance Evaluation of Desiccant Based Air Conditioning Test Rig

Energy Performance Evaluation of Desiccant Based Air Conditioning Test Rig

... solar desiccant cooling system with heat recovery for regenerating the adsorption ...DEC Air Handling Unit, airflow 1250 m 3 /h, was installed and ...the Desiccant evaporative ...solar ... See full document

11

SEPARATION AND ANALYSIS OF OIL BASED AEROSOLS FROM COMPRESSED AIR

SEPARATION AND ANALYSIS OF OIL BASED AEROSOLS FROM COMPRESSED AIR

... Water or air cooled heat exchanger cools the high temperature of the air resulting from the heat of compression. A significant amount of entrained moisture condenses into liquids. Condensate separator ... See full document

8

Thermodynamic analysis of a hybrid energy storage system based on compressed air and liquid air

Thermodynamic analysis of a hybrid energy storage system based on compressed air and liquid air

... storage system, comprising a compressed air store supplemented with a liquid air store of relatively higher energy storage capacity, is ...compressed air in a pressurised steel tank has ... See full document

10

An experimental study of a novel integrated desiccant air conditioning system for building applications

An experimental study of a novel integrated desiccant air conditioning system for building applications

... Figure 9 IDCS regenerator performance with a inlet air absolute humidity, and b volumetric air flow.. Figure 9b shows the variation of moisture addition rate from the desiccant solution [r] ... See full document

29

Show all 10000 documents...