• No results found

[PDF] Top 20 Graphene-Modified Electrode for the Selective Determination of Uric Acid Under Coexistence of Dopamine and Ascorbic Acid

Has 10000 "Graphene-Modified Electrode for the Selective Determination of Uric Acid Under Coexistence of Dopamine and Ascorbic Acid" found on our website. Below are the top 20 most common "Graphene-Modified Electrode for the Selective Determination of Uric Acid Under Coexistence of Dopamine and Ascorbic Acid".

Graphene-Modified Electrode for the Selective Determination of Uric Acid Under Coexistence of Dopamine and Ascorbic Acid

Graphene-Modified Electrode for the Selective Determination of Uric Acid Under Coexistence of Dopamine and Ascorbic Acid

... highly selective graphene-modified glassy carbon electrode (GME) is ...investigated. Selective determination of UA by this sensor in the presence of high concentrations of DA and ... See full document

13

Selective Determination of Dopamine, Ascorbic Acid and Uric Acid at SDS-MWCNTs Modified Glassy Carbon Electrode

Selective Determination of Dopamine, Ascorbic Acid and Uric Acid at SDS-MWCNTs Modified Glassy Carbon Electrode

... Compared with the bare GCE, the peak currents of DA, UA and AA increased significantly at the modified electrode. Figure 2(B) show the peak potential of AA shifts to a more negative oxidation side and the ... See full document

9

Selective Determination of Dopamine and Uric Acid at Poly(acid red 176) Modified Glassy Carbon Electrode in the Presence of Ascorbic Acid

Selective Determination of Dopamine and Uric Acid at Poly(acid red 176) Modified Glassy Carbon Electrode in the Presence of Ascorbic Acid

... in dopamine hydrochloride injection [21, ...applying modified electrode for the determination of DA in real sample [6, 19] such as human urine [9, ...the determination of DA by using ... See full document

8

Poly(3-thiophenemalonic acid) Modified Glassy Carbon Electrode for Selective Determination of Dopamine and Urine Acid in the Presence of Ascorbic Acid

Poly(3-thiophenemalonic acid) Modified Glassy Carbon Electrode for Selective Determination of Dopamine and Urine Acid in the Presence of Ascorbic Acid

... 3-thiophenemalonic acid (3-TPA) was prepared on the surface of glassy carbon electrode (GCE) in neutral solution by cyclic voltammetry ...of dopamine (DA) and uric acid ...to ... See full document

8

Elimination of Ascorbic Acid and Sensitive Detection of Uric Acid at the MnO2 Nanorods /Graphene-based Modified Electrode

Elimination of Ascorbic Acid and Sensitive Detection of Uric Acid at the MnO2 Nanorods /Graphene-based Modified Electrode

... a graphene/Pt-modified glassy carbon electrode to simultaneously characterize AA, dopamine (DA), and UA ...the graphene surface. In our previous work[23], for the purpose of selective ... See full document

10

Separation of Ascorbic Acid, Dopamine and Uric Acid by Acetone/Water Modified Carbon Paste Electrode: A Cyclic Voltammetric Study

Separation of Ascorbic Acid, Dopamine and Uric Acid by Acetone/Water Modified Carbon Paste Electrode: A Cyclic Voltammetric Study

... the determination of DA has been carried out ...the coexistence of ascorbic acid (AA) and uric acid ...(UA). Uric acid is an end product from purine derivatives in ... See full document

8

One-step Fabrication of a New Carbon Paste Electrode for Dopamine, Ascorbic acid and Uric acid determination in Serum

One-step Fabrication of a New Carbon Paste Electrode for Dopamine, Ascorbic acid and Uric acid determination in Serum

... L(+)-ascorbic acid (AA, vitamin C) is the main antioxidant found in both animals and ...28]. Uric acid (UA) and other oxypurines are the main final products of purine metabolism in the human ... See full document

13

Electrochemical Determination of Dopamine in Serum in Presence of Uric Acid and Ascorbic Acid at a Sonogel-Carbon L-cysteine Modified Electrode

Electrochemical Determination of Dopamine in Serum in Presence of Uric Acid and Ascorbic Acid at a Sonogel-Carbon L-cysteine Modified Electrode

... their selective determination in a ternary mixtures is of great importance in electrochemical ...unmodified electrode and (b) 5% L-cysteine Sonogel-Carbon modified electrode in serum ... See full document

8

Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid by Differential Pulse Voltammetry using Tiron Modified Glassy Carbon Electrode

Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid by Differential Pulse Voltammetry using Tiron Modified Glassy Carbon Electrode

... compound. The electrochemical oxidation of DA has been studied to show that it is a two-electron irreversible process with transfer of two protons. Uric acid is the primary end product of purine metabolism. ... See full document

15

Selective Determination of Epinephrine in the Presence of Ascorbic Acid and Dopamine at Silver Doped Polyglycine Modified Electrode

Selective Determination of Epinephrine in the Presence of Ascorbic Acid and Dopamine at Silver Doped Polyglycine Modified Electrode

... polyglycine modified electrode was prepared by cyclic ...the modified electrode was studied. A novel method for determination of epinephrine using cyclic voltammetry was ...the ... See full document

8

Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Graphene/Polyaniline/Glod Nanohybrids

Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Graphene/Polyaniline/Glod Nanohybrids

... functionalized-graphene modified graphite electrode (199 mV for AA and DA, 164 mV for DA and UA, and 363 mV for AA and UA) [25] and ERGO/GCE (240 mV for AA and DA, 130 mV for DA and ... See full document

12

Electrochemical Determination of Dopamine, Uric acid and Ascorbic acid at Mn0 02Sn0 98O2 Nanoparticles Modified Carbon Paste Electrode

Electrochemical Determination of Dopamine, Uric acid and Ascorbic acid at Mn0 02Sn0 98O2 Nanoparticles Modified Carbon Paste Electrode

... While modified electrode the formation of spindle-like nanostructures not only enlarges the surface area of the electrode and also improves the electron transfer rate between the electrode ... See full document

15

Electrochemical Detection of Norepinephrine in the Presence of Epinephrine, Uric Acid and Ascorbic Acid Using a Graphene-modified Electrode

Electrochemical Detection of Norepinephrine in the Presence of Epinephrine, Uric Acid and Ascorbic Acid Using a Graphene-modified Electrode

... indicates that the redox reaction involves a transfer process of two protons. The effect of solution pH on the electrochemical signal is similar to the effect of solution pH on carbon-loated nickel magnetic nanoparticles ... See full document

10

Sensitive Electrochemical Determination Uric Acid at Pt Nanoparticles Decorated Graphene Composites in the Presence of Dopamine and Ascorbic Acid

Sensitive Electrochemical Determination Uric Acid at Pt Nanoparticles Decorated Graphene Composites in the Presence of Dopamine and Ascorbic Acid

... PtNPs/GR modified electrode was successfully fabricated for the selective and quantitative detection of UA in the presence of DA and a very high concentration of ...the modified ... See full document

10

A Silver Hexacyanoferrate-Graphene Modified Glassy Carbon Electrode in Electrochemical Sensing of Uric Acid and Dopamine

A Silver Hexacyanoferrate-Graphene Modified Glassy Carbon Electrode in Electrochemical Sensing of Uric Acid and Dopamine

... catabolism and it widely exists in biological fluids, such as blood, urine and serum [3, 4]. Abnormal levels of UA may lead to several diseases like gout, Lesh-Nyhan syndrome, renal failure, hyperuricaemia, and ... See full document

14

Simultaneous Determination of Folic Acid and Uric Acid under Coexistence of L-Ascorbic Acid Using a Modified Electrode Based on Poly(3,4-Ethylenedioxythiophene) and Functionalized Single-Walled Carbon Nanotubes Composite

Simultaneous Determination of Folic Acid and Uric Acid under Coexistence of L-Ascorbic Acid Using a Modified Electrode Based on Poly(3,4-Ethylenedioxythiophene) and Functionalized Single-Walled Carbon Nanotubes Composite

... the modified electrode was applied to the determination of FA and UA in human urine ...proposed electrode system gave rise to better recoveries (Table 2) for the quantification of spiked two ... See full document

14

Highly Selective Differential Pulse Voltammetric Determination of Uric Acid using Modified Glassy Carbon Electrode

Highly Selective Differential Pulse Voltammetric Determination of Uric Acid using Modified Glassy Carbon Electrode

... [41], graphene, a novel two-dimensional (2D) carbon nanostructure, has garnered much attention due to its unique mechanical, physical and chemical ...that graphene possesses a high theoretical specific ... See full document

11

Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Nitrogen Doped Carbon Sphere Modified Glassy Carbon Electrode

Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Nitrogen Doped Carbon Sphere Modified Glassy Carbon Electrode

... NCSs modified electrode show an excellent electrocatalytic activity to oxidize small biological molecules (AA, DA and UA), and the oxidation peak do not appear to ... See full document

8

Fabrication of Poly(Aspartic Acid) Nanogold Modified Electrode and Its Application for Simultaneous  Determination of Dopamine, Ascorbic Acid, and Uric Acid

Fabrication of Poly(Aspartic Acid) Nanogold Modified Electrode and Its Application for Simultaneous Determination of Dopamine, Ascorbic Acid, and Uric Acid

... and modified electrode characterized by scanning electron microscopy ...partic acid film on the GCE shows a more uniform sur- face topography with pycnotic nanostructure with round parvules (Figure ... See full document

9

Simultaneous Determination of Epinephrine, Dopamine, Ascorbic Acid and Uric Acid by Polydopamine-nanogold Composites Modified Electrode

Simultaneous Determination of Epinephrine, Dopamine, Ascorbic Acid and Uric Acid by Polydopamine-nanogold Composites Modified Electrode

... for determination of EP, DA, AA and UA ...composites modified GCE was fabricated by a one-pot electropolymerization protocol using DA as a reducing agent and a monomer, while HAuCl ... See full document

12

Show all 10000 documents...