• No results found

[PDF] Top 20 ICRF Heating in Helical Reactor

Has 10000 "ICRF Heating in Helical Reactor" found on our website. Below are the top 20 most common "ICRF Heating in Helical Reactor".

ICRF Heating in Helical Reactor

ICRF Heating in Helical Reactor

... wavelength is only 0.5 m even at the start point, which is much smaller than the plasma minor radius (≈2 m), therefore ray tracing is applicable. The ray bounced at a R-cutoff in the plasma edge. Figure 4-a shows the ... See full document

5

Measurements of Plasma Termination in ICRF Heated Long Pulse Discharges with Fast Framing Cameras in the Large Helical Device

Measurements of Plasma Termination in ICRF Heated Long Pulse Discharges with Fast Framing Cameras in the Large Helical Device

... For monitoring plasmas and the plasma-wall interac- tions in long pulse discharges, totally about thirty video rate (30 fps) visible CCD cameras are set in some view- ports. Additionally, three visible fast framing ... See full document

5

Generation of Supersonic and Super-Alfvénic Flow Using ICRF Heating and a Magnetic Nozzle

Generation of Supersonic and Super-Alfvénic Flow Using ICRF Heating and a Magnetic Nozzle

... In cosmic plasmas, an astrophysical jet from a fast ro- tating star is one of the most interesting phenomena [1]. A helical structure is often observed in the jet, and the physical mechanism of the jet formation ... See full document

5

Experimental Results for Electron Bernstein Wave Heating in the Large Helical Device

Experimental Results for Electron Bernstein Wave Heating in the Large Helical Device

... a heating method in fusion devices, electron cy- clotron heating (ECH) has a great advantage; that is, the electron cyclotron (EC) wave antennas can be installed apart from the plasma ...a helical ... See full document

5

Design Window Analysis for the Helical DEMO Reactor FFHR-d1

Design Window Analysis for the Helical DEMO Reactor FFHR-d1

... that of FFHR-2m2. Therefore, additional analysis was conducted by related task groups to confirm the validity of this design point. Radial-build design was conducted in order to utilize this limited space to the fullest ... See full document

5

Split and Segmented-Type Helical Coils for the Heliotron Fusion Energy Reactor

Split and Segmented-Type Helical Coils for the Heliotron Fusion Energy Reactor

... joule heating at the joint sections could be accepted more easily with elevated temperature opera- tions compared to the case with low-temperature super- conductors ... See full document

5

Improved Design of a Cartridge-Type Helical Blanket System for the Helical Fusion Reactor FFHR-b1

Improved Design of a Cartridge-Type Helical Blanket System for the Helical Fusion Reactor FFHR-b1

... cartridge-type helical blanket system called the CARDISTRY-B has been proposed for the helical fusion reactor ...the helical divertor, and ...injection heating are newly equipped ... See full document

24

Ignition Analysis for D Plasma with Non-Maxwellian 3He Minority in Fusion Reactors

Ignition Analysis for D Plasma with Non-Maxwellian 3He Minority in Fusion Reactors

... demonstrated in present numerical simulations. On this purpose the particle code based on test-particle ap- proach is developed. This code solves guiding center equations for 3 He ions in toroidal magnetic field ... See full document

5

Physics of Heliotron J Confinement

Physics of Heliotron J Confinement

... a helical-axis ...(ICRF) heating plasmas have been made for understanding global energy confinement in connection with the international stellarator scaling law (ISS04), spontaneous confinement ... See full document

6

An Analysis of an ICRF Antenna with Controllable Toroidal Wavenumber in LHD

An Analysis of an ICRF Antenna with Controllable Toroidal Wavenumber in LHD

... favorable heating efficiency with low impu- rity production in the LHD, and a long discharge, with a duration time of 54 ...cyclotron heating (ECH) support [5]. One-pair superconducting helical coils ... See full document

5

A REVIEW ON LIQUID STUB TUNER FOR IMPEDANCE MATHING

A REVIEW ON LIQUID STUB TUNER FOR IMPEDANCE MATHING

... (ICRF) heating on the large helical device is characterized by high power up to 12 MW and steady state operation for 30 ...cyclotron heating has been established as one of the heating ... See full document

5

DT Fusion Ignition of LHD-Type Helical Reactor by Joule Heating Associated with Magnetic Axis Shift

DT Fusion Ignition of LHD-Type Helical Reactor by Joule Heating Associated with Magnetic Axis Shift

... type helical fusion reactor can be ignited by high-current Joule ...a helical system is analyzed ...the helical coil current is MHD ...LHD-type helical reactor is ... See full document

5

Numerical Analysis of ICRF Minority Heating in Helitoron J

Numerical Analysis of ICRF Minority Heating in Helitoron J

... minority heating in Heliotron J with special emphasis on the effect of the toroidal ripple (bumpiness) of the magnetic field ...by ICRF minority heating, a high bumpiness configuration is found to be ... See full document

5

Performance Assessment of an Allothermal Auger Gasification System for On Farm Grain Drying

Performance Assessment of an Allothermal Auger Gasification System for On Farm Grain Drying

... Reactor temperature is a key factor that affects its performance since all gasification reactions, whether endo- thermic or exothermic, are temperature sensitive. Figure 2 illustrates the temperature profile at ... See full document

14

Enhancement of Heat Transfer Coefficient through Helical Coil

Enhancement of Heat Transfer Coefficient through Helical Coil

... force. Helical coil configuration is very effective for heat exchange and chemical reactors because of their large heat transfer area in a small space with high heat transfer ...of helical coil type heat ... See full document

5

Application of EMC3-EIRENE to Estimation of Influence of a Liquid Metal Limiter on an LHD-Type Fusion Plasma

Application of EMC3-EIRENE to Estimation of Influence of a Liquid Metal Limiter on an LHD-Type Fusion Plasma

... a helical fusion reactor was ...Large Helical Device ...the helical divertor plates is significantly reduced when the limiter is inserted into the ergodic layer even without ... See full document

5

Efficient Heating at the Third-Harmonic Electron Cyclotron Resonance in the Large Helical Device

Efficient Heating at the Third-Harmonic Electron Cyclotron Resonance in the Large Helical Device

... High-harmonic heating of the electron cyclotron res- onance (ECR) is an attractive method to extend the heat- ing regime of plasma parameters by alleviating the den- sity limitation due to some cuto ff s of EC wave ... See full document

5

The Role of Combined ICRF and NBI Heating in JET Hybrid Plasmas in Quest for High D-T Fusion Yield

The Role of Combined ICRF and NBI Heating in JET Hybrid Plasmas in Quest for High D-T Fusion Yield

... the heating phase in discharge 90348 with ICRF ...central heating provided by ICRF ...on ICRF heating for core impurity control, see ... See full document

5

Design Status of the Structural Components of the Helical Fusion Reactor FFHR-d1

Design Status of the Structural Components of the Helical Fusion Reactor FFHR-d1

... The second round of the FFHR-d1 design activity is the 3D structural design of components. The supercon- ducting magnet system of FFHR-d1 comprises one pair of HCs and two sets of VFCs (the LHD has three sets of VFCs). ... See full document

6

JET Joint Undertaking progress report 1990, Volume I. Report for the period 1 January - 31 December 1990. EUR 13493 EN (EUR-JET-PR8)

JET Joint Undertaking progress report 1990, Volume I. Report for the period 1 January - 31 December 1990. EUR 13493 EN (EUR-JET-PR8)

... Contents Volume I Introduction, Background and Report Summary Technical Achievements during 1990 - Torus Systems Power Supplies and Magnet Systems Neutral Beam Heating System ICRF Heatin[r] ... See full document

224

Show all 10000 documents...