• No results found

[PDF] Top 20 On the absolute calibration of SO2 cameras

Has 10000 "On the absolute calibration of SO2 cameras" found on our website. Below are the top 20 most common "On the absolute calibration of SO2 cameras".

On the absolute calibration of SO2 cameras

On the absolute calibration of SO2 cameras

... cell calibration can give misleading re- sults since it cannot account for changes in camera sensitivity due to the presence of aerosol in the plume, as is explained ...below. Calibration with a co-located ... See full document

20

Shutter-less calibration of uncooled infrared cameras

Shutter-less calibration of uncooled infrared cameras

... of absolute and spatial deviation can be ...mean absolute deviation and the mean spa- tial standard deviation of the pixel signal voltages over the sensor ...the calibration using the offset ... See full document

8

A simplified nonlinear regression method for human height estimation in video surveillance

A simplified nonlinear regression method for human height estimation in video surveillance

... camera calibration method for estimating human height in video ...most cameras for video surveillance are installed in high positions at a slightly tilted angle, it is possible to retain only three ... See full document

9

A Variational Approach to Problems in Calibration of Multiple Cameras.

A Variational Approach to Problems in Calibration of Multiple Cameras.

... any calibration procedure is that when there are shape symmetries or constant radiance on the object, camera pose parameter estimation is not stable, however, these do not affect the 3D reconstruction ...the ... See full document

36

Calibration of uncooled thermal infrared cameras

Calibration of uncooled thermal infrared cameras

... The calibration of uncooled thermal infrared (IR) cameras to absolute temperature measurement is a time-consuming, complicated process that significantly influences the cost of an IR ...IR ... See full document

11

Reconstruction of 3D PIV data in complicated experimental arrangements

Reconstruction of 3D PIV data in complicated experimental arrangements

... the calibration target is recorded through components which significantly distort the resulting image of the pattern or particles, see paragraph ...the calibration pattern into the measurement area ... See full document

6

A. High quality cameras

A. High quality cameras

... the calibration table – for example a checkerboard pattern presented on Figure ...a calibration object has known geometry - alternate white and black ...of cameras only once after the set-up of the ... See full document

6

Elastic Scattering of Neutrons from 6Li  EUR 3454

Elastic Scattering of Neutrons from 6Li EUR 3454

... Por the absolute calibration of the cross sections, at each primary energy the neutron scattering from a polyethylene sample was measured at a certain angle.. Absolute values of the diff[r] ... See full document

18

Implementation and calibration of a multi sensor measuring system

Implementation and calibration of a multi sensor measuring system

... With the high-resolution stereo camera we take the next images of the combustion chambers machined surface. Because of the proper lighting conditions we achieve with the controllable lights the valve openings separate ... See full document

8

Calibration of Acoustic Emission System for Materials Characterization

Calibration of Acoustic Emission System for Materials Characterization

... Without applying any external loads (dynamic loading) the sample acoustic signals are produced with no deformation that is on sample. This type of static test is almost equal to calibration method. Similarly, ... See full document

8

Absolute charge calibration of scintillating screens for relativistic electron detection

Absolute charge calibration of scintillating screens for relativistic electron detection

... Oncoray, Technische Universität Dresden, Fetscher Straße 74, D-01307 Dresden, Germany 共Received 9 November 2009; accepted 18 January 2010; published online 3 March 2010兲 We report on new charge calibrations and linearity ... See full document

6

Absolute optical calibration using a simple tungsten light bulb: Experiment

Absolute optical calibration using a simple tungsten light bulb: Experiment

... We believe that we have developed a viable alternative to optical calibrations that is not only simple and cheap but also easily arranged by virtually any laboratory. An accuracy of ~15% seems realistic. In the ... See full document

5

Study on stability of reflectance characteristics of natural features for calibrating remote sensing data

Study on stability of reflectance characteristics of natural features for calibrating remote sensing data

... post-launch calibration, which produced low-quality images. The vicarious calibration technique can be adopted to provide post-calibration ...extracted. Calibration target can be generally ... See full document

32

A new method for the absolute radiance calibration for UV–vis measurements of scattered sunlight

A new method for the absolute radiance calibration for UV–vis measurements of scattered sunlight

... ibrated, because the DOAS technique is sensitive to differen- tial absorption structures and does not require absolute cali- bration. But some of the data products derived from DOAS observations (see above) can be ... See full document

16

The Climatic Importance of Uncertainties in Regional Aerosol-Cloud Radiative Forcings over Recent Decades

The Climatic Importance of Uncertainties in Regional Aerosol-Cloud Radiative Forcings over Recent Decades

... emissions, the rate of dry deposition of aerosols in the accumulation mode, and the diameter of carbonaceous aerosols emitted from biomass burning sources all con- tributed very little to global-mean CAE forcing un- ... See full document

19

A novel method for the absolute end-to-end calibration of the Auger fluorescence telescopes

A novel method for the absolute end-to-end calibration of the Auger fluorescence telescopes

... ibrated light source is done. This procedure uses a large, uniformly lit area as a light source (see fig. 1) covering the whole aperture. This so called "drum" is directly mounted to the UV filter of the FD ... See full document

5

The absolute calibration of echo sounders used for the detection of mid water organisms

The absolute calibration of echo sounders used for the detection of mid water organisms

... arguments similar to these used in a above, the effective power received by the transducer from a target with an acoustic cross-section c is ^T Since ^ and t/t are small, the solid angle[r] ... See full document

37

A novel approach for absolute radar calibration: formulation and theoretical validation

A novel approach for absolute radar calibration: formulation and theoretical validation

... vertical wind. Considering a study from Peters et al. (2005), specific attenuation can be overestimated by a factor of 2 for 1 m s −1 vertical wind, which is substantial. However, an anal- ysis of vertical wind data with ... See full document

10

Revisiting the absolute calibration of the Greenland ice-core age-scales

Revisiting the absolute calibration of the Greenland ice-core age-scales

... In order to assess the “absolute” accuracy of GICC05 and SFCP04 further, a comparison can be made with ages drawn from uranium-series dated speleothem records. The com- parison of speleothem records shown in Fig. ... See full document

8

Auto-Calibration and Three-Dimensional Reconstruction for Zooming Cameras

Auto-Calibration and Three-Dimensional Reconstruction for Zooming Cameras

... stationary cameras are concerned, the assumption of a mandatory pure rotation of the camera has been proposed in the literature [18, ...moving cameras in a pure rotation motion is not feasible in practice ... See full document

179

Show all 10000 documents...