• No results found

[PDF] Top 20 Original Article Results of type C fractures of distal radius treated by volar locking plate (VLP), an observational comparative study

Has 10000 "Original Article Results of type C fractures of distal radius treated by volar locking plate (VLP), an observational comparative study" found on our website. Below are the top 20 most common "Original Article Results of type C fractures of distal radius treated by volar locking plate (VLP), an observational comparative study".

Original Article Results of type C fractures of distal radius treated by volar locking plate (VLP), an observational comparative study

Original Article Results of type C fractures of distal radius treated by volar locking plate (VLP), an observational comparative study

... classical type of die-punch fracture that frac- ture fragments are impacted longitudinally and separated from the lunate facet, periosteum elevator is introduced into the longitudinal ... See full document

9

Volar locking plate versus external fixation with optional additional K-wire for treatment of AO type C2/C3 fractures: a retrospective comparative study

Volar locking plate versus external fixation with optional additional K-wire for treatment of AO type C2/C3 fractures: a retrospective comparative study

... and locking screw/ hole allowed securing the small fragments and provided better ...or VLP was applied for treatment of AO type C unstable distal radius frac- tures [26, ... See full document

8

Incidence of complications and secondary procedure following distal radius fractures treated by volar locking plate (VLP)

Incidence of complications and secondary procedure following distal radius fractures treated by volar locking plate (VLP)

... this study, it was shown that open injury and AO type C fracture were independently associated with these ...of distal radius fractures treated by VLP and found ... See full document

9

Comparison of radiographic and functional results of die-punch fracture of distal radius between volar locking plating (VLP) and external fixation (EF)

Comparison of radiographic and functional results of die-punch fracture of distal radius between volar locking plating (VLP) and external fixation (EF)

... die-punch fractures necessitate the open reduction and locking plate/screws fixation via volar or dorsal ...non-locking plate/screws, wrist arthroscopy, intramedullary fixation, ... See full document

7

Original Article Efficacy of volar locking plate fixation for unstable distal radius fractures in elderly patients

Original Article Efficacy of volar locking plate fixation for unstable distal radius fractures in elderly patients

... maintain fractures reduction and make for bone healing ...lock plate, the stability of osteoporotic fractures was improved greatly, and volar DRF surgical techniques were also increasingly ... See full document

7

A comparative study of analysis of functional outcome of intra articular distal radius fractures treated with dynamic external fixator and locking compression plate.

A comparative study of analysis of functional outcome of intra articular distal radius fractures treated with dynamic external fixator and locking compression plate.

... retrospective study compared the outcomes of open reduction and internal fixation with locked volar plating with closed reduction and bridging external fixation and percutaneous K wire fixation of unstable ... See full document

135

Original Article Volar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis

Original Article Volar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis

... Previous study indicated that in patients sixty- five years of age or older, surgery could not give any improvement in terms of the range of motion, PRWE and DASH scores ...included study reported outcomes ... See full document

10

Short term comparative study of external fixation versus volar locking compression plate in the treatment of unstable distal radius fractures

Short term comparative study of external fixation versus volar locking compression plate in the treatment of unstable distal radius fractures

... The original plates had round ...Compression Plate (Fig.9) (DCP was introduced in 1969 and was the standard AO plate until a few years ...hole results in movement of the bone ... See full document

72

Original Article Comparison of open reduction volar locking plate fixation and closed reduction percutaneous K-wire fixation in the treatment of AO type C1 distal radius fractures

Original Article Comparison of open reduction volar locking plate fixation and closed reduction percutaneous K-wire fixation in the treatment of AO type C1 distal radius fractures

... simple fractures, locking plate seems to be appropriate for complicated frac- tures, especially when closed reduction is not possible ...a study in which radiographic and functional outcomes ... See full document

6

Failure of volar locking plate fixation of an extraarticular distal radius fracture: A case report

Failure of volar locking plate fixation of an extraarticular distal radius fracture: A case report

... tal radius nonunion ...tibial fractures [8]. In a monozygotic twin discordant tobacco use study, Hopper and Seeman discovered a 5% to 10% bone density deficit in patients who smoked compared with ... See full document

6

Original Article Volar locking plate versus percutaneous fixation for the treatment of distal radial fractures: a meta-analysis of randomized controlled trials

Original Article Volar locking plate versus percutaneous fixation for the treatment of distal radial fractures: a meta-analysis of randomized controlled trials

... a volar locking plate has becoming increasingly popular in the treatment of distal radius fractures [1, ...However, volar locking plate fixation is expen- ... See full document

14

Clinical study of the Pronator Quadratus muscle: anatomical features and feasibility of Pronator Sparing Surgery

Clinical study of the Pronator Quadratus muscle: anatomical features and feasibility of Pronator Sparing Surgery

... and plate fixation for distal radius requires wide exposure of the fracture site with stripping of the soft tissues which may devascularize the fracture fragments ...invasive plate ... See full document

5

Role of locking compression plate for Distal Radius Fractures in Postmenopausal Women

Role of locking compression plate for Distal Radius Fractures in Postmenopausal Women

... the volar cortex result in volar and dorsal cortical bone ...of distal end of radius with respect of the radial diaphysis, a dorsal displacement fracture ...of distal radius ... See full document

143

Distal radius fractures with diaphyseal involvement: fixation with fixed angle volar plate

Distal radius fractures with diaphyseal involvement: fixation with fixed angle volar plate

... Fixed-angle volar plates can adequately stabilize artic- ular fragments and both volar and dorsal comminution, even in osteoporotic bone [8, ...the plate, with screws and pins placed in the ... See full document

7

Biomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support

Biomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support

... Angle Locking Compression Plate Distal Radius System (VA-LCP, Synthes, Switzerland) were respectively 90, 70, and 54 mm in length and 20, 18, and 22 mm in ...outer radius, and inner ... See full document

10

A prospective study on short term analysis of clinical, radiological and functional outcome of surgical management of Type B & Type C distal radius fracture with volar locking plate

A prospective study on short term analysis of clinical, radiological and functional outcome of surgical management of Type B & Type C distal radius fracture with volar locking plate

... PROSPECTIVE STUDY ON SHORT TERM ANALYSIS OF CLINICAL, RADIOLOGICAL & FUNCTIONAL OUTCOME OF SURGICAL MANAGEMENT OF TYPE B & TYPE C DISTAL RADIUS FRACTURE WITH VOLAR ... See full document

125

Diagnosis of Medically Important Viruses: A Molecular Approach

Diagnosis of Medically Important Viruses: A Molecular Approach

... All fractures united at the three months ...mean volar tilt of 3.4°. The radial inclination and volar tilt did not show any significant change from surgery to final ...19 type B and C ... See full document

6

Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius : randomised controlled trial

Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius : randomised controlled trial

... and locking plate fixation are inherent in the design of the implants, there are several different implant systems and several different options for the positioning of wires and screws; the details of the ... See full document

11

Volar Locking Plate Breakage after Nonunion of a Distal Radius Osteotomy

Volar Locking Plate Breakage after Nonunion of a Distal Radius Osteotomy

... osteotomy. Plate breakages seem to occur in the vicinity of unfilled screw holes, adjacent to the fracture or osteotomy site [1–4, ...A locking mecha- nism on the screws implies that they cannot loosen out ... See full document

6

Using self drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study

Using self drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study

... Therefore, distal screw length has to be determined prior to ...any study assessing screw length ...First, radius width (measured from pa radio- graphs) correlates to radius depth, ...i.e. ... See full document

7

Show all 10000 documents...