[PDF] Top 20 Plate osteosynthesis of fractures of the shaft of the humerus: comparison of limited contact dynamic compression plates and locking compression plates

Has 10000 "Plate osteosynthesis of fractures of the shaft of the humerus: comparison of limited contact dynamic compression plates and locking compression plates" found on our website. Below are the top 20 most common "Plate osteosynthesis of fractures of the shaft of the humerus: comparison of limited contact dynamic compression plates and locking compression plates".

Plate osteosynthesis of fractures of the shaft of the humerus: comparison of limited contact dynamic compression plates and locking compression plates

Plate osteosynthesis of fractures of the shaft of the humerus: comparison of limited contact dynamic compression plates and locking compression plates

... fractured humerus shafts treated with DCP and LCP using minimally invasive plate osteosynthesis (MIPO) techniques, and showed that there was no significant differ- ence when outcomes and ... See full document

6

Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures

Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures

... In our study, radiologic findings of both groups showed complete bony union except 2 patients. And those 2 pa- tients achieved bony union after revision surgery. Their preoperative angulations in AP and lateral X-ray ... See full document

8

Functional Outcome of Diaphyseal Fractures of Shaft of Humerus Treated Surgically with Locking Compression Plates in Osteoporotic Bones: A Prospective study

Functional Outcome of Diaphyseal Fractures of Shaft of Humerus Treated Surgically with Locking Compression Plates in Osteoporotic Bones: A Prospective study

... bone fractures using plates and screws is a standard successful ...with plates and screws leads to additional trauma and disturbance of the bone blood supply, which increases the risk of delayed ... See full document

94

Comparison between minimally invasive, percutaneous osteosynthesis and locking plate osteosynthesis in 3 and 4 part proximal humerus fractures

Comparison between minimally invasive, percutaneous osteosynthesis and locking plate osteosynthesis in 3 and 4 part proximal humerus fractures

... PHILOS plate and 23 % for the ...the dynamic stabilization and controlled sintering and fracture consolidation of the head ...stable plates, only in cases of k-wire perforation or due to the wish of ... See full document

9

Mono  versus polyaxial locking plates in distal femur fractures – a biomechanical comparison of the Non Contact Bridging  (NCB) and the PERILOC plate

Mono versus polyaxial locking plates in distal femur fractures – a biomechanical comparison of the Non Contact Bridging (NCB) and the PERILOC plate

... such fractures in either osteoporotic as well as in younger individuals with higher bone ...testing plate osteosynthesis at an open gap fracture model, which was biomechanically similar to a ... See full document

7

Clinical outcomes of allograft with locking compression plates for elderly four-part proximal humerus fractures

Clinical outcomes of allograft with locking compression plates for elderly four-part proximal humerus fractures

... considerably limited compared with the normal side, there were no significant differences in pain and daily activity between the unaffected and affected sides at the last follow-up according to the ...fibular ... See full document

8

The Effects of Bone Screw Configurations on the Interfragmentary Movement in a Long Bone Fixed by a Limited Contact Locking Compression Plate

The Effects of Bone Screw Configurations on the Interfragmentary Movement in a Long Bone Fixed by a Limited Contact Locking Compression Plate

... Mid-shaft fractures of the femur are very common and one of the most prevalent fractures, especially in car ac- cidents ...segmental fractures of mid-shaft femur can be treated by ... See full document

11

Is Distal Femur Locking Plate a Superior Implant in Distal Femur Fracture?

Is Distal Femur Locking Plate a Superior Implant in Distal Femur Fracture?

... femoral fractures, ad- mitted in the hospital were treated using various modes of internal fixation like dynamic condylar screw, distal femur locking compression plate and distal femur ... See full document

6

EFFECTIVENESS OF LOCKING VERSUS DYNAMIC COMPRESSION PLATES FOR DIAPHYSEAL FOREARM FRACTURES

EFFECTIVENESS OF LOCKING VERSUS DYNAMIC COMPRESSION PLATES FOR DIAPHYSEAL FOREARM FRACTURES

... forearm fractures in ...intimate contact between the plate and bone [4] Development of the LC-DCP and point contact fixator was based on the theory that, if friction and intimate ... See full document

17

Outcome of proximal humerus locking plate fixation for proximal humerus fractures using the neer shoulder score

Outcome of proximal humerus locking plate fixation for proximal humerus fractures using the neer shoulder score

... Proximal humerus fractures are common fractures presenting to any orthopaedic ...these fractures. These fractures are difficult to treat from the first evaluation to final ... See full document

5

Treatment of distal humeral fractures using conventional implants  Biomechanical evaluation of a new implant configuration

Treatment of distal humeral fractures using conventional implants Biomechanical evaluation of a new implant configuration

... test in simulated flexion of the arm was followed by cyc- lic loading in extension until failure occurred. Clinically, distal screw pull-out at the lateral column is frequently reported for angular stable plating in 90° ... See full document

7

Comparison of outcomes and analysis of risk factors for non-union in locked plating of closed periprosthetic and non-periprosthetic distal femoral fractures in a retrospective cohort study

Comparison of outcomes and analysis of risk factors for non-union in locked plating of closed periprosthetic and non-periprosthetic distal femoral fractures in a retrospective cohort study

... In the secondary analysis of risk factors for non-union, comminution was identified as a strong predictor of non- union. A systematic review of distal femoral non-unions showed metaphyseal comminution to be the most com- ... See full document

10

Percutaneous locking plates for fractures of the distal tibia: Our experience and a review of literature

Percutaneous locking plates for fractures of the distal tibia: Our experience and a review of literature

... closed fractures of either type. Exclusion criteria were diaphyseal fractures, non rec onstructable pilon fractures requiring fine wire external fixation, and open ...tibial fractures were ... See full document

5

The use of bidirectional rapid reductor in minimally invasive treatment of bicondylar tibial plateau fractures: preliminary radiographic and clinical results

The use of bidirectional rapid reductor in minimally invasive treatment of bicondylar tibial plateau fractures: preliminary radiographic and clinical results

... calcaneal fractures and received satisfactory outcomes ...The compression bolt which played as the bridge of lateral and medial plate could provide efficient compression force to further ... See full document

11

A Comparison of Locking Versus Non-Locking Plates in Distal Femur Fractures

A Comparison of Locking Versus Non-Locking Plates in Distal Femur Fractures

... the locking plate the screw head has threads which lock into the plate, and the combination of screws and plate create a stable construct for comminuted and osteo- porotic ...of locking ... See full document

5

Influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study

Influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study

... tubular plate with lag screws and a prepared hook (1/3 TP + L + H) (DePuy Synthes, Japan), a one-third tubular plate with lag screws without a hook (1/3 TP + L) (DePuy Synthes, Japan), and LCP (DePuy ... See full document

10

Functional Outcome of the Distal Femur Locking Compression Plates in the Treatment of Fractures of Distal Femur

Functional Outcome of the Distal Femur Locking Compression Plates in the Treatment of Fractures of Distal Femur

... the locking plate do not need it because of this when axial loading cycles is increased first the screws loosens then due to reduction of frictionforce, plate also loosenand if this occurs ... See full document

147

Efficacy comparison of intramedullary nails, locking plates and conservative treatment for displaced proximal humeral fractures in the elderly

Efficacy comparison of intramedullary nails, locking plates and conservative treatment for displaced proximal humeral fractures in the elderly

... study, the shoulder function scores were similar among the surgical groups and the conservative groups, and the VAS scores and forward elevation were only better in the surgical groups in the management of 2-part and ... See full document

8

Comparative Study of Management of Proximal Humerus Fractures in Elderly by Conservative Method Versus Operative Locking Compression Plate

Comparative Study of Management of Proximal Humerus Fractures in Elderly by Conservative Method Versus Operative Locking Compression Plate

... The study of literature has revealed predominance of prox- imal humeral fractures in females in an elderly age group. This has been evident in other published studies. In our study, the male to female ratio was ... See full document

8

Comparison of efficacy of the intermittent pneumatic compression with a high- and low-pressure application in reducing the lower limbs phlebolymphedema

Comparison of efficacy of the intermittent pneumatic compression with a high- and low-pressure application in reducing the lower limbs phlebolymphedema

... multichamber compression sleeve, supporting the opinion that its effectiveness during treatment is higher than a single-chamber ...intermittent compression with a pressure of 120 mmHg, which led to ... See full document

10