• No results found

[PDF] Top 20 Seismic Response of the ACR(TM) Reactor Building

Has 10000 "Seismic Response of the ACR(TM) Reactor Building" found on our website. Below are the top 20 most common "Seismic Response of the ACR(TM) Reactor Building".

Seismic Response of the ACR(TM) Reactor Building

Seismic Response of the ACR(TM) Reactor Building

... the ACR-700 reactor building under the design earthquake is determined using two dynamic ...the reactor building are established using a stick model and a three-dimensional finite ... See full document

8

Results and insight from interim seismic margin assessment of the Advanced CANDU Reactor (ACR) 1000® reactor

Results and insight from interim seismic margin assessment of the Advanced CANDU Reactor (ACR) 1000® reactor

... following seismic events need to be identified in the ...(e.g., reactor building, reactor auxiliary building, ...a seismic induced ... See full document

10

Effect of Structural Modelling on the Response of a Reactor Building under Incoherent Seismic Ground Motion Excitation

Effect of Structural Modelling on the Response of a Reactor Building under Incoherent Seismic Ground Motion Excitation

... The structural geometry is extracted from the conventional 2D general overview and formwork drawings and structural surfaces are generated, see Figure 2. The structural surfaces are then meshed to generate the ... See full document

10

Seismic Analysis of Embalse Nuclear Power Plant for Life Extension Assessment

Seismic Analysis of Embalse Nuclear Power Plant for Life Extension Assessment

... The reactor building consists of an external pre-stressed concrete cylindrical shell and dome, and an internal building made up of reinforced concrete slabs and shear walls, connected to a ...minor ... See full document

7

Development of a Seismic Evaluation System (SES) for HANARO

Development of a Seismic Evaluation System (SES) for HANARO

... HANARO reactor building is ...DRS(Design Response Spectrum) of the HANARO reactor building is provided as a criterion for the seismic safety ...floor response analysis ... See full document

8

Seismic Resistant Analysis of Coupled Model of Reactor Coolant System and Reactor Building

Seismic Resistant Analysis of Coupled Model of Reactor Coolant System and Reactor Building

... From engineering point of view, Mr. Chang Chen pointed out that decoupling criteria should be based on the deviation of the system response which was very complex. He discussed the decoupling problem after the ... See full document

6

Probabilistic response analysis for ncoe scenario earthquake with focus on spatial variation of seismic ground motion

Probabilistic response analysis for ncoe scenario earthquake with focus on spatial variation of seismic ground motion

... for Seismic Margin Assessment) benchmark project organized by IAEA, the participants conducted soil-structure interaction analysis to predict the seismic response of the Unit 7 reactor ... See full document

10

Coupled vs Uncoupled Reactor Building / Reactor Coolant System Seismic Analysis - A Short Review

Coupled vs Uncoupled Reactor Building / Reactor Coolant System Seismic Analysis - A Short Review

... In this review we have shown that decoupling criteria are built so as to introduce shifts of less than 10% in modal fre- quencies. However, this doesn’t always ensure that the overall response level will be ... See full document

8

Seismic Ground Motion Incoherency Effects on Soil-Structure  Interaction Response of NPP Building Structures

Seismic Ground Motion Incoherency Effects on Soil-Structure Interaction Response of NPP Building Structures

... on seismic SSI responses of a typical axisymmetric nuclear reactor building and two industrial buildings with significant mass ...SSI response we used both stochastic and deterministic ... See full document

7

Uncertainty Of Different Modeling Methods Of NPP Building Subject To Seismic Ground Motions

Uncertainty Of Different Modeling Methods Of NPP Building Subject To Seismic Ground Motions

... NPP reactor building in two ways, using a 3D FE model (Figure 4a) with shell elements and using a conventional embedded SR model (Figure ...performed seismic-response analysis using 200 ... See full document

8

Seismic analysis of reactor building of a nppbased on asce 4-98 and rcc-g method

Seismic analysis of reactor building of a nppbased on asce 4-98 and rcc-g method

... floor response spectra (FRS) of containment of the Nuclear Power Plant (Design according to RCC-G Standard) are little than the FRS calculated from stiffness values of ASCE 4-98 ... See full document

5

Effects of Aircraft   Impact on a Seismically Isolated Reactor Building (K214)

Effects of Aircraft Impact on a Seismically Isolated Reactor Building (K214)

... the response of the isolation system to aircraft ...representative seismic isolation ...the response of a representative isolated reactor building subjected to the impact from a ... See full document

6

Three-Dimensional Probabilistic Nonlinear Response Analysis of the Mühleberg Nuclear Power Plant Reactor Building Drywell Internal Structure

Three-Dimensional Probabilistic Nonlinear Response Analysis of the Mühleberg Nuclear Power Plant Reactor Building Drywell Internal Structure

... the reactor pedestal, with in-phase response due to the orthogonal ground motion input components increasing the radial ...2D response, energy is probably radiated out into the Reactor ... See full document

10

Soil-Structure   Interaction Analysis Of RBMK-1000 MW Type NPP For Seismic Event

Soil-Structure Interaction Analysis Of RBMK-1000 MW Type NPP For Seismic Event

... The floor response spectra generated with the soil supported model can be used for seismic evaluation of the equipment and commodities in the Reactor Building. Seismic[r] ... See full document

8

Reanalysis and Evaluation of Seismic Response of Reactor Building

Reanalysis and Evaluation of Seismic Response of Reactor Building

... its’ seismic analysis of nuclear island was in accordance with the approaches in RCC-G standard for the model M310 in France, in which the Simplified impedance method was employed for the consideration of ...of ... See full document

5

SSI Analysis for a Reactor Building with High Frequency Seismic Ground Motion

SSI Analysis for a Reactor Building with High Frequency Seismic Ground Motion

... the building frequencies; how many sets of time histories and at what frequency ranges are appropriate; how many seconds each of the time histories should have; what are the PGAs for each set; what are the target ... See full document

8

Seismic Evaluation  of Containment Shell - WWER-1000 Type Reactor Building

Seismic Evaluation of Containment Shell - WWER-1000 Type Reactor Building

... A global finite element model is used for investigation of the seismic response of the whole building structure.. This model describes all main parts of the reactor [r] ... See full document

6

Study on the Soil-Structure   Interaction Model under Vertical Earthquake Motions (K173)

Study on the Soil-Structure Interaction Model under Vertical Earthquake Motions (K173)

... BWR reactor building part is used in this simulation ...the building part is multi-degree-of-freedom model shown in ...Vertical seismic response model of the building properly ... See full document

8

A  New Method for Essential Reduction of Seismic and External Loads on NPP's  Structures, Systems and Components (K279)

A New Method for Essential Reduction of Seismic and External Loads on NPP's Structures, Systems and Components (K279)

... floor response spectra is proposed in the ...than seismic external loads the acceleration range of floor response spectra could be dropped in factor 2 to 3 or even more depending on a number of ... See full document

5

Seismic Margin Assessment of a Reactor Building

Seismic Margin Assessment of a Reactor Building

... For the margin assessment using a dynamic response analysis the input time histories corresponding to the different intensity levels are applied simultaneously in x-, y- and z-direction. For the margin assessment ... See full document

10

Show all 10000 documents...