• No results found

[PDF] Top 20 A Study of Cross-Flow Air Heating via a Multiport Serpentine Microchannel Heat Exchanger

Has 10000 "A Study of Cross-Flow Air Heating via a Multiport Serpentine Microchannel Heat Exchanger" found on our website. Below are the top 20 most common "A Study of Cross-Flow Air Heating via a Multiport Serpentine Microchannel Heat Exchanger".

A Study of Cross-Flow Air Heating via a Multiport Serpentine Microchannel Heat Exchanger

A Study of Cross-Flow Air Heating via a Multiport Serpentine Microchannel Heat Exchanger

... present study was to investigate air side forced convection heat transfer and fluid flow characteristics, microchannel heat exchanger performance characteristics, and ... See full document

235

Second Law Analysis of a Multiport Serpentine Microchannel Heat Exchanger

Second Law Analysis of a Multiport Serpentine Microchannel Heat Exchanger

... current study, independent and dependent parameters were identified for the uncertainty ...mass flow rate, average fluid temperature, Reynolds number, heat transfer rate, and entropy ... See full document

145

Experimental Study on Heat Transfer and Flow Characteristics of Air Cooling through Cross-flow Microchannel Heat Exchanger

Experimental Study on Heat Transfer and Flow Characteristics of Air Cooling through Cross-flow Microchannel Heat Exchanger

... for heat transfer and pressure drop for wavy fins and these correlations can predict 95% of experimental results within ...on air-side heat transfer and friction factor characteristics of five kinds ... See full document

136

Thermal Performance Study Of A Prototype Multiport Heat Exchanger

Thermal Performance Study Of A Prototype Multiport Heat Exchanger

... fluid flow behaviour in Minichannel Heat Exchangers (MICHX), however, the examination of air side in a multiport serpentine slab heat exchanger is ...on air ... See full document

18

Thermal Performance Study of a Prototype Multiport Heat Exchanger

Thermal Performance Study of a Prototype Multiport Heat Exchanger

... water flow in a microchannel test ...convective heat transfer in microchannels correlates with Brinkman number at constant wall heat flux boundary ...wall heat flux boundary condition ... See full document

149

A Study on Various Heat Transfer Enhancement Techniques

A Study on Various Heat Transfer Enhancement Techniques

... The flow structure holds good when the diameter and the heights are ...enrolls heat transfer and pressure ...maximum heat transfer rate is ... See full document

5

Performance Comparison of a Helical Coil Heat...

Performance Comparison of a Helical Coil Heat...

... for heating and cooling ...tube heat exchanger and helical heat exchanger for different flow configuration under variable operating ...efficient heat exchanger is ... See full document

5

Numerical Simulation On Micro Channel Heat Exchanger

Numerical Simulation On Micro Channel Heat Exchanger

... for microchannel is lightweight, environmental restoration, global climate control, and industrial chemical ...of microchannel heat exchangers are include man-portable heating and cooling ... See full document

24

Investigation of a Counter Flow Microchannel Heat Exchanger Performance with Using Nanofluid as a Coolant

Investigation of a Counter Flow Microchannel Heat Exchanger Performance with Using Nanofluid as a Coolant

... phase heat transfer coefficient especially for laminar flow. Higher heat transfer coefficient was achieved mostly in the entrance region of the microchannels and the enhancement was weaker in the ... See full document

9

Flow distribution analysis in a heat 
		exchanger with different header configurations

Flow distribution analysis in a heat exchanger with different header configurations

... This study presents the numerical results of liquid flow distribution in parallel flow heat ...the flow distribution for different header cross section (like circle, square, ... See full document

6

A Review On Enhancement Of Heat Transfer In Microchannel Heat Exchanger

A Review On Enhancement Of Heat Transfer In Microchannel Heat Exchanger

... the heat exchanger a coolant fluid is required, which dissipate heat form the ...water, air, engine oil and ethylene glycol. The heat transfer performance of these coolants depends on ... See full document

7

CFD study for cross flow heat exchanger with integral finned tube

CFD study for cross flow heat exchanger with integral finned tube

... to study the temperature difference for cross flow heat exchanger with smooth tube and low integral finned ...The study includes geometry creation with dimensions (250×500×1200) ... See full document

10

Heat Transfer and Numerical Analysis in Microchannel Heat Exchanger Using Nanofluids : A Review Divyesh Ubale 1, P. V. Ubale2

Heat Transfer and Numerical Analysis in Microchannel Heat Exchanger Using Nanofluids : A Review Divyesh Ubale 1, P. V. Ubale2

... Conventional heat transfer fluids like oil, water and ethylene glycol are used on a large scale in many industries, including power generation, chemical processes, heating and cooling processes, ... See full document

6

Development of experimental techniques for measurement of heat transfer rates in heat exchangers in oscillatory flows

Development of experimental techniques for measurement of heat transfer rates in heat exchangers in oscillatory flows

... rejects heat to the stack as its temperature is raised above that of the local ...irreversible heat transfer takes place from the stack plate to the gas parcel causing the expansion of gas parcel volume and ... See full document

37

Direct Contact Heat Exchange for Energy Recovery  from Hot Temperature Petroleum Refinery Streams

Direct Contact Heat Exchange for Energy Recovery from Hot Temperature Petroleum Refinery Streams

... contact heat exchangers which keep the fluids exchanging heat separate by the use of tubes or plates ...contact heat exchangers. Direct contact heat exchanger are classified according ... See full document

10

A COMPREHENSIVE REVIEW ON EATHE

A COMPREHENSIVE REVIEW ON EATHE

... of air-conditioning in desert climates; hence there is a significant use of energy in the domestic air conditioning ...domestic air- conditioning operates from the beginning of April to the end of ... See full document

14

Behavioral Analysis of Entrapped Condensate in a Vehicle Charge-Air-Cooler

Behavioral Analysis of Entrapped Condensate in a Vehicle Charge-Air-Cooler

... intake air of the vehicle before it enters the combustion ...Compressed air has a much higher density of oxygen than ambient air hence, when this compressed intake air ...charge air) ... See full document

139

Cataract Detection

Cataract Detection

... traditional air cooled heat sinks to keep the junction temperature below acceptable ...the air cooled heat sinks which defies the market demand for more compact electronics devices ...the ... See full document

7

Thermal design of steam coil for forced draft counter to cross flow air 
		cooled heat exchanger for extremely low ambient condition

Thermal design of steam coil for forced draft counter to cross flow air cooled heat exchanger for extremely low ambient condition

... the heat exchanger freezes, more steam and more auxiliary power (fan, motor, pump) is required to defreeze the fluid and it will also affect the performance of heat ... See full document

10

Design of a Solar Organic Rankine Cycle Prototype for 1 kW Power Output

Design of a Solar Organic Rankine Cycle Prototype for 1 kW Power Output

... During the rainy seasons, there are frequent power cuts in Assam. Which causes interruption in several works. Also, there is a lack of sufficient power plants in Assam to meet the electrical power demand in the state. ... See full document

11

Show all 10000 documents...