[PDF] Top 20 Using self drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study
Has 10000 "Using self drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study" found on our website. Below are the top 20 most common "Using self drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study".
Using self drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study
... intra-articular fractures needs to be investigated, but we assume that more complex fracture patterns require the use of individually oriented ...of screws with predetermined ... See full document
7
Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
... the radius and the other platform distal on the second metacarpal, offered by Synthes (code – ...threaded self-drilling pins will be used with the proximal platforms that are ...the ... See full document
7
Complication rates and reduction potential of palmar versus dorsal locking plate osteosynthesis for the treatment of distal radius fractures
... oversized screws, was not confirmed in our ...of volar plating, tendon irritations seem to derive from technical errors and oversized screws ...oversized screws may derive from the traditional ... See full document
6
The influence of distal screw length on the primary stability of volar plate osteosynthesis—a biomechanical study
... biomechanical study was conducted on 11 paired fresh-frozen ...unicortical distal screw ...extra-articular distal radius fractures (AO-23 A3) was ...Polyaxial volar locking ... See full document
8
Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating technique
... A distal Henry approach was carried out in the interval between the flexor carpi radialis tendon and the radial ...The distal part of the pronator quadratus muscle was released from the ...and plate ... See full document
6
Short term comparative study of external fixation versus volar locking compression plate in the treatment of unstable distal radius fractures
... the radius moves.If there is a dislocation , it is technically the radius that displaced dorsally or palmarly with respect to the ...ulna.The distal radioulnar joint has both rotational and ... See full document
72
Comparative study on the analysis of functional outcome in distal radius articular fractures treated by closed reduction through bridging external fixator augmented with K-wires and Volar-locking plating
... issuesdon’t affect elderly people and low-demand patients probably due to low functional and physical demand. In general anatomic reduction should be pursued in younger and high-demand elderlypatients (because of longer ... See full document
136
Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes
... The patients were given general/regional anesthesia at the discretion of the anesthesiologist. All of the surg- eries were performed under tourniquet control. The frac- ture was approached through the base of flexor ... See full document
8
Effectiveness of Biological Fixation of Distal Tibial Fractures with Locking Compression Plates in Adults
... assessed using Karlsson and Peterson scoring system for ankle ...Template using the uninvolved leg with the operated leg especially valgus, varus, anterior and posterior angulation is ... See full document
129
Volar Locking Plate Breakage after Nonunion of a Distal Radius Osteotomy
... DR plate breakage that were fabricated from grade II titanium ...the volar surface of the distal radius. There are seven distal screw holes ...first plate and seven proximal ... See full document
6
Original Article Volar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis
... of volar locking plate fixation and K-wire fixation on treatment of distal radius fractures was ...of volar locking plate and K-wires for distal radius ...of ... See full document
10
Benefits of Palmer T- Plate Osteosynthesis in Unstable Distal Radius Fracture Management
... Our study has been conducted in locally to assess the functional outcome of unstable distal radius fracture in adults treated with palmer T-plate ...T- plate can be the choice of ... See full document
5
Mid-term functional outcome after the internal fixation of distal radius fractures
... radiographic study, Mackenney et ...this study did not look at results after fixation with a volar locking plate, which has specific design applications for use in osteo- porotic unstable ... See full document
8
Volar locking plates not touching the flexor pollicis longus tendon appear as prominences on radiographs: a cadaver study
... thus distal placement of the plate is a factor for higher Soong ...rupture using lateral radiographs alone would be ...status using ultrasound following VLP surgery ...surgery using ... See full document
7
Original Article Volar locking plate versus percutaneous fixation for the treatment of distal radial fractures: a meta-analysis of randomized controlled trials
... a volar locking plate is becoming increasingly popular for treatment of distal radius fractures, it is not clear whether it is superior to other conventional treatment methods such as ... See full document
14
Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model
... the distal radioulnar joint were left ...and distal radioulnar joints, creating an unstable intra-articular fracture with both radial- and unlar-side fracture frag- ...the distal radius across ... See full document
8
Original Article Results of type C fractures of distal radius treated by volar locking plate (VLP), an observational comparative study
... the study of investigating results of AO type C3 fractures of distal radius, Schneeberger et al found favorable results in wrist motion and grip strength at postoperative 12 months (70- 100% ... See full document
9
Clinical outcomes after carbon-plate osteosynthesis in patients with distal radius fractures
... Our study has certain ...our study is valuable for the following reasons: ...In distal radius fractures, this is achievable within 3 months after ...respect, radius frac- tures ... See full document
7
Treatment of neglected mal:union: of the distal radius: a cases series study
... Malunited fractures of the distal radius with volar angulation Corrective osteotomy in 6 cases using the volar approach.. Nalbantoglu U, Gereli A, Ucar Y, Turkmen M.[r] ... See full document
5
Volar locking distal radius plates show better short-term results than other treatment options: a prospective randomised controlled trial
... for study purposes. Volar tilt of the distal radius joint surface and anterior- posterior radial inclination were measured in degrees and ulnar variance as an indicator of radius ... See full document
9
Related subjects