• No results found

Assembling the server

8.2 Replacement of non-hot-plug components

8.2.5 Assembling the server

V

CAUTION!

● Before attaching the cover, make sure no unnecessary parts or tools are left inside the server.

● Before turning on the server, make sure the top cover is closed.

V

CAUTION

Be careful not to pinch fingers or clothes when sliding out the server or pushing it back. Failure to do so may cause injury.

Figure 38: Mounting the top cover

Ê Place the top cover on the server (1).

Make sure that each bolt is positioned in the corresponding nut. Ê Push the top cover as far as it will go in the direction of the arrow (2).

Figure 39: Securing the two knurled screws

Ê Secure the top cover with the two knurled screws on the rear panel (1).

This section explains the specifications for the server. The specifications for this server are liable to be updated without any notice. Please be forewarned. System Board

Processor

Memory Modules Configuration

Interfaces

System board type D2863

Chipset Intel 3420

Processor quantity and type

1x Intel Xeon/Pentium/Core i3/Celeron processor

Memory slots 4

Memory slot type DIMM (DDR3) Memory capacity

(min. - max.)

1 GB - 32 GB Memory protection ECC

Memory notes with 2 channels and 2 slots per channel

USB connectors 8 x USB 2.0 (2x front (+1x optional), 4x rear, 1x internal)

Onboard or integrated controllers

Slots

RAID Controller Modular RAID 0/1 controller with "Integrated Mirroring Enhanced" (SAS IME) for SAS1.0. RAID levels 0, 1 and 1E are supported for internal hard disk drive configurations.

Modular RAID 0/1 controller with “MegaRAID functionality” (SAS MegaRAID) for SAS2.0.

RAID levels 0, 1,10 and 1E are supported for internal hard disk drive configurations.

Modular RAID 5/6 controller with "MegaRAID functionality" (SAS MegaRAID) for SAS1.0 and SAS2.0. RAID levels 0, 1, 10, 1E, 5, 50, 6 and 60 are supported for internal hard disk drive configurations. SATA Controller A 6-port SATA controller is integrated on the system

board; up to four SATA hard disk drives can be connected to the controller. The LSI Embedded MegaRAID software (SATA Software RAID) supports RAID levels 0, 1 and 10.

Remote Management Controller

Integrated Remote Management Controller (iRMC S2, 32 MB attached memory incl. graphics controller), IPMI 2.0 compatible

Trusted Platform Module (TPM)

Infineon / 1.2 (option)

PCI-Express Gen2 x4 1 x (for Modular RAID only)

Drive bays

Operating Panel

Dimensions / Weight Hard disk bay configuration

2 x 3,5-inch, for SAS / SATA or 4 x 2,5-inch for SAS/SATA/SSD optional

Accessible drive bays 1 x 5.25/0.5-inch

1 x 3.5/0.5-inch for ServerView Local Service Panel or front VGA + USB 2.0

Notes accessible drives all possible options described in relevant system configurator

Operating buttons On/off switch NMI button Reset button

Status LEDs System status (amber / yellow) Identification (blue)

Hard disks access (green) Power (amber / green) Status LED at system

rear side:

System status (amber / yellow) Identification (blue)

LAN connection (green) LAN speed (green / yellow) Service displays

(optional):

Dimensions (Base unit specific)

Environmental

Electrical values

Rack (W x D x H) 431 x 557x 42.5 mm (without projecting parts) Mounting Depth Rack 572 mm

Noise emission Measured according to ISO 7779 and declared according to ISO9296

Sound pressure (LpAm)

36 dB(A) (idle) / 42 dB(A) (operating) Sound power (LWAd;

1B = 10dB) 5.2 B (idle) / 5.7 B (operating) Operating ambient temperature 10 - 35°C Operating relative humidity 10 - 85 % (non condensing) Power supply configuration

1x standard power supply Max. output of standard

power supply

350 W Rated voltage range 100 - 240 V

Rated frequency range 100 - 127 V / 200 - 240 V

3rd party rack installing in 55 requirements 47 A accessible drives 18 acclimatization time 43, 95

Advanced Video Redirection 19

ambient conditions 25

articulated cable guide 53

ASR&R 18 availability 18 AVR 19 B BIOS security functions 81 BIOS update 21 C cables connecting 61 disconnecting 61 CE marking 24, 37

Class A Compliance Statement 38

cleaning keyboard 79 monitor 79 mouse 79 server 79 components hardware 11 Video 58 consumables 41 control panel 63 controls 63 correcting faults 83 CSS indicator 63, 65, 69 D data manipulation 11 data protection 81 data security 18 DataCenter rack requirements 46 date, incorrect 86 delivery note 27, 44

devices, connecting to server 57

disconnecting cables 61

disposal, devices 42

drive

defective 86

“dead” 86

dummy module, HDD module 96, 99

DVD drive 18

DVD drive activity indicator 66

E ECC 18 electrical data 23 electromagnetic compatibility 24, 37 electrostatic-sensitive devices (ESD) 36 EMC directive 24 EMC regulations 96, 99

incorrect time 86

no display on monitor 85

no mouse pointer 85

power-on indicator does not light 83

screen remains blank 84

screen shows flickering stripes 85

server switches itself off 84

Error Correcting Code 18

error message on screen 87

ESD (electrostatic-sensitive devices) 36

F fault

drifting display on monitor 85

drive defective 86

incorrect date 86

incorrect time 86

no display on monitor 85

screen remains blank 84

screen shows flickering stripes 85

FCC statement 38

features 14

flash EPROM 21

G

Global Error indicator 63, 66, 68

graphics card 59

H

hard disk activity indicator 63

hard disk activity, indicator 65

hard disk drive 16

handling 95 installation frame 91 HDD module 18, 91 acclimatization time 43, 95 indicators 67 installation frame 97 installing 97 hot-plug HDD module 18 I ID button 64 ID card 63, 64 product name 44, 64 serial number 44, 64 ID indicator 65 IME 17, 76 indicators CSS 63, 65, 69 DVD drive activity 66 Global Error 63, 66, 68

hard disk activity 63, 65

hot-plug HDD module 67

ID 65

on server 63

operating 65

ServerView Local Service Panel 66 system error 66, 68 information, additional 13 installation connectors 57 Installing server 53 installing in 3rd party rack 55 PRIMECENTER Rack 49

installing in the rack, notes 40

installing, server 45

Integrated Mirroring Enhanced 17,

76

integrated Remote Management Controller 19 iRMC S2 19 L labels 42 LAN connectors 58 laser information 35

light emitting diode (LED) 35

lithium battery 33

M

MAC address 64

main memory 103

mains voltage, connecting server 59

meaning of the symbols 22

MegaRAID 17, 76

monitor

display drifts 85

no display 85

mouse, no mouse pointer on screen 85 N NMI button 64 noise level 25 notational conventions 22 O On/Off button 64

onboard SAS controller configuring 78

onboard SATA controller 16, 75

configuring 78

operating system, installing 78

operation 63

overload 20

P

packaging 41, 44

PCI SAS controller, configuring 78

PDA 18, 20

power supply unit cable clamp 60

power-on indicator 65

does not light 83

PRIMECENTER Rack

R

RAID controller is not configured for this drive 86

RAID level 18

recycling devices 42

regulations and standards 24

Remote Storage 19 removing, server 45 requirements 3rd party rack 47 DataCenter rack 46 PRIMECENTER Rack 46 reset button 64 return of devices 42 routing cables 53 S safety instructions 29 safety standards 24

SAS IME controller 17

SAS MegaRAID controller 17

SAS/SATA RAID controller 17

configuring 76 saving energy 41 screen error message 87 flickering 85 remains blank 84

shows flickering stripes 85

security function 11 serial connector 58 serial number 44, 64 Server installing 53 server ambient conditions 25

electrical data 23 fitting in rack 45 indicators 63 installing 45 noise level 25 operation 63 product name 44 property protection 81 removing 45 routing cables 53 serial number 44 service 21 starting up 63

switches itself off (error) 84

switching off 72 switching on 72 technical data 23 transport 39 troubleshooting 83 unpacking 44 ventilation clearance 25 weight 25 server management 20

ServerView Installation Manager 21,

77

ServerView Local Service Display 18

ServerView Local Service Panel 66

ServerView Operations Manager 20

supported functions 20

ServerView Remote Management 21

service

PRIMERGY Diagnostic LED 21

server 21

touch point 21

service LAN connector 19

support bracket 50

switch off time, defining 73

switch on time, defining 73

switching off, server 72

switching on, server 72

system board

system board, features 15

system fan 104 system information 64 T target group 11 technical data 23 telescopic rail 53 time, incorrect 86 tips 83 top cover 102 touch point service 21 TPM 15 transport damage 27, 44

transporting the server 39

troubleshooting 83

troubleshooting, server 83

Trusted Platform Module 15

U

unpacking, server 44

USB connector 58

using the cable clamp 60

V

ventilation clearance 25

Video connector 58

W

Related documents