8.2 Replacement of non-hot-plug components
8.2.5 Assembling the server
V
CAUTION!● Before attaching the cover, make sure no unnecessary parts or tools are left inside the server.
● Before turning on the server, make sure the top cover is closed.
V
CAUTIONBe careful not to pinch fingers or clothes when sliding out the server or pushing it back. Failure to do so may cause injury.
Figure 38: Mounting the top cover
Ê Place the top cover on the server (1).
Make sure that each bolt is positioned in the corresponding nut. Ê Push the top cover as far as it will go in the direction of the arrow (2).
Figure 39: Securing the two knurled screws
Ê Secure the top cover with the two knurled screws on the rear panel (1).
This section explains the specifications for the server. The specifications for this server are liable to be updated without any notice. Please be forewarned. System Board
Processor
Memory Modules Configuration
Interfaces
System board type D2863
Chipset Intel 3420
Processor quantity and type
1x Intel Xeon/Pentium/Core i3/Celeron processor
Memory slots 4
Memory slot type DIMM (DDR3) Memory capacity
(min. - max.)
1 GB - 32 GB Memory protection ECC
Memory notes with 2 channels and 2 slots per channel
USB connectors 8 x USB 2.0 (2x front (+1x optional), 4x rear, 1x internal)
Onboard or integrated controllers
Slots
RAID Controller Modular RAID 0/1 controller with "Integrated Mirroring Enhanced" (SAS IME) for SAS1.0. RAID levels 0, 1 and 1E are supported for internal hard disk drive configurations.
Modular RAID 0/1 controller with “MegaRAID functionality” (SAS MegaRAID) for SAS2.0.
RAID levels 0, 1,10 and 1E are supported for internal hard disk drive configurations.
Modular RAID 5/6 controller with "MegaRAID functionality" (SAS MegaRAID) for SAS1.0 and SAS2.0. RAID levels 0, 1, 10, 1E, 5, 50, 6 and 60 are supported for internal hard disk drive configurations. SATA Controller A 6-port SATA controller is integrated on the system
board; up to four SATA hard disk drives can be connected to the controller. The LSI Embedded MegaRAID software (SATA Software RAID) supports RAID levels 0, 1 and 10.
Remote Management Controller
Integrated Remote Management Controller (iRMC S2, 32 MB attached memory incl. graphics controller), IPMI 2.0 compatible
Trusted Platform Module (TPM)
Infineon / 1.2 (option)
PCI-Express Gen2 x4 1 x (for Modular RAID only)
Drive bays
Operating Panel
Dimensions / Weight Hard disk bay configuration
2 x 3,5-inch, for SAS / SATA or 4 x 2,5-inch for SAS/SATA/SSD optional
Accessible drive bays 1 x 5.25/0.5-inch
1 x 3.5/0.5-inch for ServerView Local Service Panel or front VGA + USB 2.0
Notes accessible drives all possible options described in relevant system configurator
Operating buttons On/off switch NMI button Reset button
Status LEDs System status (amber / yellow) Identification (blue)
Hard disks access (green) Power (amber / green) Status LED at system
rear side:
System status (amber / yellow) Identification (blue)
LAN connection (green) LAN speed (green / yellow) Service displays
(optional):
Dimensions (Base unit specific)
Environmental
Electrical values
Rack (W x D x H) 431 x 557x 42.5 mm (without projecting parts) Mounting Depth Rack 572 mm
Noise emission Measured according to ISO 7779 and declared according to ISO9296
Sound pressure (LpAm)
36 dB(A) (idle) / 42 dB(A) (operating) Sound power (LWAd;
1B = 10dB) 5.2 B (idle) / 5.7 B (operating) Operating ambient temperature 10 - 35°C Operating relative humidity 10 - 85 % (non condensing) Power supply configuration
1x standard power supply Max. output of standard
power supply
350 W Rated voltage range 100 - 240 V
Rated frequency range 100 - 127 V / 200 - 240 V
3rd party rack installing in 55 requirements 47 A accessible drives 18 acclimatization time 43, 95
Advanced Video Redirection 19
ambient conditions 25
articulated cable guide 53
ASR&R 18 availability 18 AVR 19 B BIOS security functions 81 BIOS update 21 C cables connecting 61 disconnecting 61 CE marking 24, 37
Class A Compliance Statement 38
cleaning keyboard 79 monitor 79 mouse 79 server 79 components hardware 11 Video 58 consumables 41 control panel 63 controls 63 correcting faults 83 CSS indicator 63, 65, 69 D data manipulation 11 data protection 81 data security 18 DataCenter rack requirements 46 date, incorrect 86 delivery note 27, 44
devices, connecting to server 57
disconnecting cables 61
disposal, devices 42
drive
defective 86
“dead” 86
dummy module, HDD module 96, 99
DVD drive 18
DVD drive activity indicator 66
E ECC 18 electrical data 23 electromagnetic compatibility 24, 37 electrostatic-sensitive devices (ESD) 36 EMC directive 24 EMC regulations 96, 99
incorrect time 86
no display on monitor 85
no mouse pointer 85
power-on indicator does not light 83
screen remains blank 84
screen shows flickering stripes 85
server switches itself off 84
Error Correcting Code 18
error message on screen 87
ESD (electrostatic-sensitive devices) 36
F fault
drifting display on monitor 85
drive defective 86
incorrect date 86
incorrect time 86
no display on monitor 85
screen remains blank 84
screen shows flickering stripes 85
FCC statement 38
features 14
flash EPROM 21
G
Global Error indicator 63, 66, 68
graphics card 59
H
hard disk activity indicator 63
hard disk activity, indicator 65
hard disk drive 16
handling 95 installation frame 91 HDD module 18, 91 acclimatization time 43, 95 indicators 67 installation frame 97 installing 97 hot-plug HDD module 18 I ID button 64 ID card 63, 64 product name 44, 64 serial number 44, 64 ID indicator 65 IME 17, 76 indicators CSS 63, 65, 69 DVD drive activity 66 Global Error 63, 66, 68
hard disk activity 63, 65
hot-plug HDD module 67
ID 65
on server 63
operating 65
ServerView Local Service Panel 66 system error 66, 68 information, additional 13 installation connectors 57 Installing server 53 installing in 3rd party rack 55 PRIMECENTER Rack 49
installing in the rack, notes 40
installing, server 45
Integrated Mirroring Enhanced 17,
76
integrated Remote Management Controller 19 iRMC S2 19 L labels 42 LAN connectors 58 laser information 35
light emitting diode (LED) 35
lithium battery 33
M
MAC address 64
main memory 103
mains voltage, connecting server 59
meaning of the symbols 22
MegaRAID 17, 76
monitor
display drifts 85
no display 85
mouse, no mouse pointer on screen 85 N NMI button 64 noise level 25 notational conventions 22 O On/Off button 64
onboard SAS controller configuring 78
onboard SATA controller 16, 75
configuring 78
operating system, installing 78
operation 63
overload 20
P
packaging 41, 44
PCI SAS controller, configuring 78
PDA 18, 20
power supply unit cable clamp 60
power-on indicator 65
does not light 83
PRIMECENTER Rack
R
RAID controller is not configured for this drive 86
RAID level 18
recycling devices 42
regulations and standards 24
Remote Storage 19 removing, server 45 requirements 3rd party rack 47 DataCenter rack 46 PRIMECENTER Rack 46 reset button 64 return of devices 42 routing cables 53 S safety instructions 29 safety standards 24
SAS IME controller 17
SAS MegaRAID controller 17
SAS/SATA RAID controller 17
configuring 76 saving energy 41 screen error message 87 flickering 85 remains blank 84
shows flickering stripes 85
security function 11 serial connector 58 serial number 44, 64 Server installing 53 server ambient conditions 25
electrical data 23 fitting in rack 45 indicators 63 installing 45 noise level 25 operation 63 product name 44 property protection 81 removing 45 routing cables 53 serial number 44 service 21 starting up 63
switches itself off (error) 84
switching off 72 switching on 72 technical data 23 transport 39 troubleshooting 83 unpacking 44 ventilation clearance 25 weight 25 server management 20
ServerView Installation Manager 21,
77
ServerView Local Service Display 18
ServerView Local Service Panel 66
ServerView Operations Manager 20
supported functions 20
ServerView Remote Management 21
service
PRIMERGY Diagnostic LED 21
server 21
touch point 21
service LAN connector 19
support bracket 50
switch off time, defining 73
switch on time, defining 73
switching off, server 72
switching on, server 72
system board
system board, features 15
system fan 104 system information 64 T target group 11 technical data 23 telescopic rail 53 time, incorrect 86 tips 83 top cover 102 touch point service 21 TPM 15 transport damage 27, 44
transporting the server 39
troubleshooting 83
troubleshooting, server 83
Trusted Platform Module 15
U
unpacking, server 44
USB connector 58
using the cable clamp 60
V
ventilation clearance 25
Video connector 58
W