• No results found

AVIONICS Workshop

TECHNICAL REQUIRMENTS

AVIONICS Workshop

MECH Workshop

AVIONICS Workshop

145.A.25 Yes Yes Yes Yes

145.A.30 Yes Yes Yes Yes

145.A.35 Yes Yes Yes Yes

145.A.40 Yes Yes Yes Yes

145.A.42 Yes Yes Yes Yes

145.A.45 Yes Yes Yes Yes

145.A.47 Yes Yes Yes Yes

145.A.50 Yes Yes Yes Yes

145.A.55 Yes Yes Yes Yes

145.A.60 Yes Yes Yes Yes

145.A.65 Yes Yes Yes Yes

2.1 MOE Yes Yes Yes Yes

2.2 MOE Yes Yes Yes Yes

2.3 MOE Yes Yes Yes Yes

2.4 MOE Yes Yes Yes Yes

2.5 MOE Yes Yes Yes Yes

2.6 MOE Yes Yes Yes Yes

2.7 MOE Yes Yes Yes Yes

2.8 MOE Yes Yes Yes Yes

2.9 MOE Yes Yes Yes Yes

2.10 MOE Yes No No No

2.11 MOE Yes Yes Yes Yes

2.12 MOE Yes Yes Yes Yes

2.13 MOE Yes Yes Yes Yes

2.15 MOE Yes No No No

2.16 MOE Yes Yes Yes Yes

2.17 MOE iff appl iff appl iff appl iff appl

2.18 MOE Yes Yes Yes Yes

2.19 MOE Yes Yes Yes Yes

2.20 MOE Yes Yes Yes Yes

2.21 MOE iff appl iff appl iff appl iff appl

2.22 MOE Yes Yes No No

2.23 MOE Yes No No No

2.24 MOE Yes Yes Yes Yes

2.25 MOE Yes Yes Yes Yes

2.26 MOE Yes Yes Yes Yes

2.27 MOE Yes Yes Yes Yes

2.28 MOE Yes Yes Yes Yes

Part 145 GM 145.A.65 (c)(1) Safety and quality policy, maintenance procedures and quality system

PARA Comment HANGAR ENGINE

Workshop

MECH Workshop

AVIONICS Workshop

3.10 MOE iff appl iff appl iff appl iff appl

3.11 MOE iff appl iff appl iff appl No

3.12 MOE Yes Yes No No

3.13 MOE Yes Yes Yes Yes

3.14 MOE Yes Yes Yes Yes

145.A.70 Yes Yes Yes Yes

145.A.75 Yes Yes Yes Yes

145.A.80 Yes Yes Yes Yes

145.A.85 Yes Yes Yes Yes

145.A.95 iff appl iff appl iff appl iff appl

Note 1: ‘if appl’ means if applicable or relevant.

Note 2: In the line station case all line stations should be audited at the frequency agreed with the competent authority within the limits of AMC 145.A.65 (c)(1).

>> Go to IR >> Go to AMC (a) >> Go to Contents

>> Go to AMC (b) >> Go to AMC (b)(2) >> Go to AMC (b)(3) >> Go to AMC (c)(1) >> Go to AMC (c)(2)

145.A.70 Maintenance organisation exposition

(a) ‘Maintenance organisation exposition’ means the document or documents that contain the material specifying the scope of work deemed to constitute approval and showing how the organisation intends to comply with this Part. The organisation shall provide the competent authority with a maintenance organisation exposition, containing the following information:

1. A statement signed by the accountable manager confirming that the maintenance organisation exposition and any referenced associated manuals define the organisation's compliance with this Part and will be complied with at all times. When the accountable manager is not the chief executive officer of the organisation then such chief executive officer shall countersign the statement;

2. the organisation's safety and quality policy as specified by 145.A.65; 3. the title(s) and name(s) of the persons nominated under 145.A.30(b);

4. the duties and responsibilities of the persons nominated under 145.A.30(b), including matters on which they may deal directly with the competent authority on behalf of the organisation;

5. an organisation chart showing associated chains of responsibility between the persons nominated under 145.A.30(b);

6. a list of certifying staff and support staff; 7. a general description of manpower resources;

8. a general description of the facilities located at each address specified in the organisation's approval certificate;

9. a specification of the organisation's scope of work relevant to the extent of approval;

10. the notification procedure of 145.A.85 for organisation changes; 11. the maintenance organisation exposition amendment procedure;

12. the procedures and quality system established by the organisation under 145.A.25 to 145.A.90;

13. a list of commercial operators, where applicable, to which the organisation provides an aircraft maintenance service;

Part 145 145.A.70 Maintenance organisation exposition 16. a list of contracted organisations, where applicable.

(b) The exposition shall be amended as necessary to remain an up-to-date description of the organisation The exposition and any subsequent amendment shall be approved by the competent authority.

(c) Notwithstanding paragraph (b) minor amendments to the exposition may be approved through an exposition procedure (hereinafter called indirect approval).

AMC 145.A.70 (a) Maintenance organisation exposition

The following information should be included in the maintenance organisation exposition:

The information specified in 145.A.70(a) subparagraphs (6) and (12) to (16) inclusive, whilst a part of the maintenance organisation exposition, may be kept as separate documents or on separate electronic data files subject to the management part of said exposition containing a clear cross-reference to such documents or electronic data files.

The exposition should contain the information, as applicable, specified in this AMC. The information may be presented in any subject order as long as all applicable subjects are covered. Where an organisation uses a different format, for example, to allow the exposition to serve for more than one approval, then the exposition should contain a cross reference Annex using this list as an index with an explanation as to where the subject matter can be found in the exposition.

The exposition should contain information, as applicable, on how the maintenance organisation complies with Critical Design Configuration Control Limitations’ (CDCCL) instructions.

Small maintenance organisations may combine the various items to form a simple exposition more relevant to their needs.

The operator may use electronic data processing (EDP) for publication of the maintenance organisation exposition. The maintenance organisation exposition should be made available to the approving competent authority in a form acceptable to the competent authority. Attention should be paid to the compatibility of EDP publication systems with the necessary dissemination of the maintenance organisation exposition, both internally and externally.

PART 0 GENERAL ORGANISATION (Operators within the European Union)

This section is reserved for those maintenance organisations approved under Part- 145 who are also operators within the European Union.

PART 1 MANAGEMENT

1.1 Corporate commitment by the accountable manager

1.2 Safety and quality policy

1.3 Management personnel

1.4 Duties and responsibilities of the management personnel

1.5 Management organisation chart

1.6 List of certifying staff and B1 and B2 support staff

1.7 Manpower resources

1.8 General description of the facilities at each address intended to be approved 1.9 Organisations intended scope of work