The tenderer is to detail below any additional items with quantities and rates not previously included to complete the build up of the lump sum tender price for this section of the works. Should the tenderer fail to insert any items here, it will be deemed that his lump sum price for the tender includes all items and no subsequent claim for any additional item will be entertained.
CARRIED TO COLLECTION -
Item Ref Description Quantity Unit Rate Amount Dhs
COLLECTION - BILL NO. 3 - BLOCK WORKS
From Page No. 3 / 1 759,955.00
From Page No. 3 / 2 -
CARRIED TO GRAND SUMMARY 759,955.00
Item Ref Description Quantity Unit Rate Amount Dhs
BILL NO 4
ROOFING & WATERPROOFING WORKS FLAT ROOFING
Clean the entire surface and remove all debris from the roof structure to receive waterproofing system Modern Combo System
A Supply and Apply Polyurethane foam 45mm thick
(avg) with density 48kg/m3 3711 m2 126.00 467,586.00
B Acrylic UV resistant protective coat 3711 m2
C Grotectile Separation layer 3711 m2
D Ridges in panel using expansion joint board and cement
sand mortar 3711 m2
E Protective screed concrete (M26/10) to slope 3711 m2 F Angle fillet in cement sand mortar along the parapet/
upstand 500 m
G Final Coat acrylic cementation protective coating 3711 m2
H Extra over work to roof drain, as detailed. 28 No 79.00 2,212.00 J Extra over for water proof to Roof water tank RCC
decking 293 m2 105.00 30,765.00
CARRIED TO COLLECTION 500,563.00
B4/1
Included in Above Item -A
Item Ref Description Quantity Unit Rate Amount Dhs BILL NO 4( Contd.)
ROOFING & WATERPROOFING WORKS (Contd.) Upstands and parapets to roofing
A 21/2' x 21/2" cement and sand (1:3) angle fillet 660 LM 8.00 5,280.00 B Ruberit PE2000 minaralized: max girth 150mm 660 m 15.00 9,900.00 C 0.9mm thick x 150mm girth Plain aluminium mill
finish flashing 660 m 18.00 11,880.00
Waterproofing to all kitchens, bathrooms, toilets, planters and all wet areas generally
D Cement sand angle fillet to wet areas. 1134 LM 8.00 9,072.00 E 1 layer of Trem proof 60 single component bitumen
modified 1.5mm thick membrane (horizontal) 541 m2 44.00 23,804.00 F Trem proof 60, single component modified 1.5mm thick
membrane girth as per drawing to wet areas (vertical) 1134 m 11.00 12,474.00
Sundries
Allow Provisional Qty of 2000m2 for below Item G Two coats of bituminous paint as damp proof coating on
concrete /masonary walls to approval (behind Aluminium
cladding) 2000 m2 5.00 10,000.00
H Water Proofing to external planters Provisional Sum
J Water Proofing to external waterbody. Provisional Sum
K Water Proofing to Ground Floor exposed areas. 807 m2 105.00 84,735.00 L Water proofing over metal decking at side entrances 49 m2 105.00 5,145.00
CARRIED TO COLLECTION 172,290.00
Item Ref Description Quantity Unit Rate Amount Dhs BILL NO 4( Contd.)
ROOF & WATERPROOFING WORKS (Contd.) ADDITIONAL ITEMS
The tenderer is to detail below any additional items with quantities and rates not previously included to complete the build up of the lump sum tender price for this section of the works. Should the tenderer fail to insert any items here, it will be deemed that his lump sum price for the tender includes all items and no subsequent claim for any additional item will be entertained.
Note: The Contractor is reuired to insure the roofing and othe rwaterproofing works in favour of the Employer for a period of 10 years against any defects or leakages.
CARRIED TO COLLECTION -
B4/3
Item Ref Description Quantity Unit Rate Amount Dhs
From Page No. 4 / 1 500,563.00
From Page No. 4 / 2 172,290.00
From Page No. 4 / 3 -
CARRIED TO GRAND SUMMARY 672,853.00
B4/4
COLLECTION-BILL NO. 4 - ROOFING & WATERPROOFING
Item Ref Description Quantity Unit Rate Amount Dhs
BILL NO 5
CARPENTRY & JOINERY DOORS
Supply and install timber doors; complete with wooden frames rebated or plain fixed to block/concrete wall, with epoxy coated mild steel holdfast, hardwood sub frames and matching hardwood architraves on both s ides finished and installed to Architect's approval;
- All fire rated doors shall be 54 mm thick soilid core flush doors
- All other doors shall be 45 mm thick solid core flush doors - The fire rated doors shall have intumescent strips all
around as reuired by the Dubai Civil Defence Department.
- All fire rated doors shall be labelled
- All fire rated doors shall be to B.S. 459 Part 3 with calcium silicate boards of thickness to achieve specified fire rating
- All glass in vision panels in fire rate doors shall be 6 mm Provisional Sum thick wired fire rated glass to approval with intumescent
gasket.
- Doors on upstands to have frame on all four sides with rubber seal to have weather proof assembly
- All doors to have sound insulating quilt internally to approval
- All doors to have minimum 6 mm clearance from F.F.L - All doors to have solidwood lipping all around
All door frames to have full width to match the thickness of the wall
CARRIED TO COLLECTION
Item Ref Description Quantity Unit Rate Amount Dhs
V - Veneer finished on both sides with of 0.6 mm decorative ash/cherry beech veneer to match the EK wing, stained to Architect's approval finished with two coats of polyurathane lacquer paint, high gloss Flush for Frames and Architraves
Frames and architraves shall be solid beachwood stamed to Architect's approval, finished with two polyurathene lacquer panit to match the doors Flush Doors with Decorative Veneer on one side and laminated (decorative veneer pattern) finish on the other
VL - Veneer finished on one sides with of 0.6 mm decorative ash/cherry beech veneer to match the existing EK wing, stained to Architect' s approval, finished with two coats of polyurathane lacquer
paint , high gloss finish and 12 mm thick laminate Provisional Sum
(decorative veneer pattern ) on the other side.
Finish for Frames and Architraves
Frames and architraves shall be solid Beachwood stained to Architect's approval.
finished with two coats of polyurathane lacquer paint to match the doors.
LAMINATED DOORS