• No results found

Configuration Setup - AVEVA Engineering & AVEVA P&ID - A Worked Example

In document Tags Training Guide (Page 178-189)

Exercise 5 – List Manage

9.1 Compare/Update

9.1.3 Compare / Update – AVEVA Engineering and AVEVA Instrumentation

9.1.4.1 Configuration Setup - AVEVA Engineering & AVEVA P&ID - A Worked Example

database:

To illustrate this; Enter AVEVA Engineering-Tags module asPROCENGuser “B” with the following details:

Username:B. PROCENG; Password:B; MDB:A-TAGS Open ‘Lines list’ list view from Process Lines category.

Click the Compare/Update/Linkbutton located on the ‘Manage’ toolbar to display the secondary buttons, then the ‘Open’ to bring up a dialogue prompt and display a new contextualCompare/Update Actionstab on the ribbon bar.

Select ‘AVEVA P&ID’ from the pick list of available source databases as shown, as this is source application where the target engineering databases (via the Tags module) will be ‘getting’ its P&ID/Schematic data (or source data) from.

The ribbon menu will now display an included the ‘Login’ button in the ‘Source’ group.

www.aveva.com

Click the ‘Options’ button in the ‘Configuration’ group, to display the Options form.

Click the ‘Configure AVEVA P&ID…’ button in the ‘Configuration’ group, to display the Configure Source form.

An input address will point to the name of a required SQL database, Port number and Service name.

Allre le vant value sof th e Addre sswillb e sup p lie d b y th e sy ste m sadm inistrator.

Click the ‘Test Connection’ button to verify connection to the setup ‘AVEVA P&ID PIDRep service’. A valid connection will return a prompt form with the information as shown:

Click the ‘OK’ buttons on both the service connection and ‘Configure source’ forms to eliminate them from view, and return to the ‘Options’ form.

In th e e ve nt of an unsucce ssfulconne ction te st, orif th e following e rrorm e ssage isdisp lay e d, th e n th e se rvice can b e m anually starte d from th e windowsSe rvice stoolson th e m ach ine h osting th e se rvice . Ple ase re fe rto “Ap p e ndix A”forfurth e rde tail.

Ple ase re fe rto Ap p e ndix A forfurth e rde tail.

Click the ‘Manage Configuration’ button on the Options form to initiate the first step (Step 1 of 6) of the ‘Compare / Update Configuration Wizard’, and create a new configuration as previously demonstrated.

www.aveva.com

Create a new configuration as previously demonstrated.

(Step 2 of 6) Source Element Type.

Source: Select the entry ‘AVEVA P&ID’ from the drop down list.

Click on the ‘Login’ button

located besides the ‘Source’ pick list, to log in to a listed AVEVA P&ID project. Select the project ‘IPE’.

Th e ‘Login’b utton isonly visib le if an AVEVA P&ID Proje ct h asnot alre ady b e e n logge d into e arlie r.

Display Name: Enter the text ‘P&ID 001:

The selected AVEVA P&ID project has been pre setup via the integration service, and will be the source of source element types and attributes for mapping, as well as source data.

Click the ‘Select’ button and fill in the details as shown:

Element Type: Select “LINE”

Name Attribute: Select “Line Number”

from the available pull-down list.

Unique Attribute: Select “ID” from the available pull-down list.

www.aveva.com

(Step 3 of 6) Destination Element Type.

Display Name: Enter the text

‘Engineering Line’ in the text field Click the ‘Next’ button to proceed to the next step.

(Step 4 of 6) Define Rule Set

Th isste p isonly ap p licab le if th e Advance d Rule sisin use .

Project Configuration File: Retain the blank text field.

This allows user to select a “Project Configuration”

(e.g.%SAMDFLTS%\ModelManagement\Project Configuration.xml), if the advanced rules are required.

Rule Set: Retain the blank field.

Th isallowsuse rsto se le ct th e ap p rop riate a Rule Se t if th e advance d rule sare re quire d.

Use Advanced Rules: Retain the unchecked checkbox.

Restrict this Configuration to Admin Users Only: Retain the unchecked checkbox.

(Step 5 of 6) Define Source Filter(s)

Include a filter, which allows for the population of just pipelines, without inherent branches.

Click the ‘Next’ button to proceed to the next step.

(Step 6 of 6) Define Attribute Mapping(s) Map the attributes as shown:

www.aveva.com

Click the ‘Finish’ button to exit the attribute mapping form, and save the configuration. Click the ‘OK’ button on the information prompt to exit the wizard, and return to the ‘Options’ form.

Click the ‘OK’ button on the ‘Options’ form to exit the setup options.

The configuration display name P&ID 001: Pipelines will now be available on the configuration pick list in the ‘Source Selection’ group.

Select the ‘P&ID 001: Pipelines’ entry from the configuration pick list to populate the Compare/Update grid with available pipelines from the selected AVEVA P&ID project.

All entries are listed as ‘Not Matched’ as they have no matches with objects in the target database.

Th e Advance d configuration m ode cannot b e use d with th isdata source

Update the Engineering database as demonstrated previously, ensuring to create new data beneath the ‘LineTags’ group, in the ‘LineTags World’, ensuring to observe for any reported errors.

www.aveva.com

All newly created lines can be displayed on a pre-existing :LineTag based linelist.

Click on the ‘LogOff’ button on the ribbon menu, to disconnect from the current AVEVA P&ID project.

Comparisons and updates will no longer be possible.

Click on the ‘LogOff’ button on the ribbon menu, to disconnect from the current AVEVA P&ID project.

Comparisons and updates will no longer be possible.

9.2 View and Highlight Items on Schematic Diagrams and 3D Model in List View

In a List view, items (elements) that are associated (linked) with a schematic diagram and 3D model can be displayed and viewed in Diagram Viewer and 3D Viewer.

This user (s) can also highlight changes made to schematic diagram objects between selected sessions on which an item is located. This is described in the worked example below:

In document Tags Training Guide (Page 178-189)