Entry 1 attribute is triggered under arm mode, the Entry Delay Timer will begin to countdown The system must be disarmed before the timer expires or an alarm will be
6. Device Management
6.4. Edit Device
Step1. UnderDevice Managementwebpage, click “Edit”. The Control Panel will enter device editing page.
Step2.Proceed to edit device settings, click “Submit” when you are satisfied with all settings or information.
Name:Enter a name for the device, A maximum of 20 characters are allowed
Zone:Select the device zone number.
Attribute:The Attribute setting determines Control Panel reaction when the device is triggered under different system modes. Different accessory devices will have different available attribute for selection according to their function.
For more information about Control Panel response
Attribute List:
Perimeter
When the system is in Away and Home Arm mode, or counting down Entry / Exit Delay Timer, if a “Perimeter” device is triggered, a “Burglar Alarm” will be activated immediately and reported.
Perimeter, FollowerAway and Home Arm Mode:
When the system is in Away and Home Arm mode, if a “Perimeter, Follower” device is triggered, a “Burglar Alarm” will be activated immediately and reported.Away and Home Arm Entry Delay:
When the system is counting down Away or Entry Entry Delay Timer, if a “Perimeter, Follower” device is triggered, the Control Panel will wait until the Entry Timer expires before activating a “Burglar Alarm”. If the system is disarmed before Entry Time expires, the Control Panel will not respond.Exit Delay:
When the system is counting down Exit Delay Timer, if a “Perimeter, Follower” device is triggered, the Control Panel will not respond.
Interior
When the system is in Away Arm mode, if an “Interior” device is triggered, a “Burglar Alarm” will be activated immediately and reported.
When the system is in Home Arm mode, if an “Interior” device is triggered, the Control Panel will not respond.Away and Home Arm Entry Delay:
When the system is counting down Away Arm Entry Delay Timer, if an “Interior” device is triggered, a “Burglar Alarm” will be activated immediately and reported.
When the system is counting down Home Arm Entry Delay Timer, if an “Interior” device is triggered, the Control Panel will not respond.Exit Delay:
When the system is counting down Exit Delay Timer, if a “Interior” device is triggered, the Control Panel will not respond.
Interior, FollowerAway and Home Arm Mode:
When the system is in Away Arm mode, if an “Interior, Follower” device is triggered, a “Burglar Alarm” will be activated immediately and reported.
When the system is in Home Arm mode, if an “Interior, Follower” device is triggered, the Control Panel will not respond.Away and Home Arm Entry Delay:
When the system is counting down Away Arm Entry Delay Timer, if an “Interior, Follower” device is triggered, the Control Panel will wait until the Entry Timer expires before activating a “Burglar Alarm”. If the system is disarmed before Entry Time expires, the Control Panel will not respond.
When the system is counting down Home Arm Entry Delay Timer, if an “Interior, Follower” device is triggered, the Control Panel will not respond.Exit Delay:
When the system is counting down Exit Delay Timer, if a “Interior, Follower” device is triggered, the Control Panel will not respond.
Interior with DelayAway and Home Arm Mode:
When the system is in Away Arm mode, if an “Interior with Delay” device is triggered, the Control Panel will start an Entry Delay countdown timer according to Entry 1 Delay setting programmed for the user to disarm the system. (please refer to5.4. Areafor detail)
If the delay period expires and no correct PIN code has been entered, the Control Panel will activate its built-in siren immediately and follow Entry Timer Extendsetting. (please refer to5.4. Areafor detail)
If Entery Timer Extend is set to OFF, the Control Panel will report a Burglar Alarmimmediately.
If Entery Timer Extend is set to ON, the Control Panel will wait for 30 seconds before reporting aBurglar Alarm. If the panel is disarmed within 30 seconds, no burglar alarm will be reported.
When the system is in Home Arm mode, if an “Interior with Delay” device is triggered, the Control Panel will not respond.
When the system is counting down Away Arm Entry Delay Timer, if an “Interior with Delay” device is triggered, the Control Panel will wait until the Entry Timer expires before activating a “Burglar Alarm”. If the system is disarmed before Entry Time expires, the Control Panel will not respond.
When the system is counting down Home Arm Entry Delay Timer, if an “Interior with Delay” device is triggered, the Control Panel will not respond.Exit Delay:
When the system is counting down Exit Delay Timer, if an “Interior with Delay” device is triggered, the Control Panel will not respond.
Entry 1 / Entry 2Away and Home Arm Mode:
When the system is in Away and Home Arm mode, if an “Entry 1” or “Entry 2” device is triggered, the Control Panel will start an Entry Delay countdown timer according to Entry 1 Delay or Entry 2 Delay setting programmed for the user to disarm the system. (please refer to5.4. Areafor detail)
If the delay period expires and no correct PIN code has been entered, the Control Panel will activate its built-in siren immediately and follow Entry Timer Extendsetting. (please refer to5.4. Areafor detail)
If Entery Timer Extend is set to OFF, the Control Panel will report a Burglar Alarmimmediately.
If Entery Timer Extend is set to ON, the Control Panel will wait for 30 seconds before reporting aBurglar Alarm. If the panel is disarmed within 30 seconds, no burglar alarm will be reported.
Away and Home Arm Entry Delay:
When the system is counting down Away or Home Entry Delay Timer, if an “Entry 1” or “Entry 2” device is triggered, the Control Panel will wait until the Entry Timer expires before activating a “Burglar Alarm”. If the system is disarmed before Entry Time expires, the Control Panel will not respond.Exit Delay:
When the system is counting down Exit Delay Timer, if an “Entry1” or “Entry 2” device is triggered, the Control Panel will not respond.
Home/DelayAway and Home Arm Mode:
When the system is in Away Arm mode, if a “Home/Delay” device is triggered, a “Burglar Alarm” will be activated immediately and reported.
When the system is in Home Arm mode, if a “Home/Delay” device is triggered, the Control Panel will start an Entry Delay countdown timer according to Entry 1 Delay setting programmed for the user to disarm the system. (please refer to5.4. Areafor detail)
If the delay period expires and no correct PIN code has been entered, the Control Panel will activate its built-in siren immediately and follow Entry Timer Extendsetting. (please refer to5.4. Areafor detail)
If Entery Timer Extend is set to OFF, the Control Panel will report a Burglar Alarmimmediately.
burglar alarm will be reported.
Away and Home Arm Entry Delay:
When the system is counting down Away or Home Entry Delay Timer, if a “Home/Delay” device is triggered, the Control Panel will wait until the Entry Timer expires before activating a “Burglar Alarm”. If the system is disarmed before Entry Time expires, the Control Panel will not respond.Exit Delay:
When the system is counting down Exit Delay Timer, if a “Home/Delay” device is triggered, the Control Panel will not respond.
Silent Burglar
When the system is in Away and Home Arm mode, or counting down Entry / Exit Delay Timer, if a “Silent Burglar” device is triggered, the Control Panel will report a “Burglar Alarm” but will not activated any audiable siren.
Burglar Outdoor
When the system is in Away and Home Arm mode, if a “Burglar Outdoor” device is triggered, the Control Panel will report a “Burglar Outdoor Alarm” but will not activated any audible siren.
24 Hour
The24 Hour device is active all the time regardless of system mode or Entry / Exit Time. When a 24 Hour device is triggered, the Control Panel will activate and report a “Burglar Alarm” immediately.
Fire
TheFire device is active all the time regardless of system mode or Entry / Exit Time. When aFiredevice is triggered, the Control Panel will activate and report a “Fire Alarm” immediately.
Medical Emergency
TheMedical Emergencydevice is active all the time regardless of system mode or Entry / Exit Time. When aMedical Emergencydevice is triggered, the Control Panel will activate and report a “Medical Alarm” immediately.
Water
TheWaterdevice is active all the time regardless of system mode or Entry / Exit Time. When a Water device is triggered, the Control Panel will activate and report a “Water Alarm” immediately.
Set/Unset (For Door Contact Only)
If the Door Contact is set to Set/Unset, the system will be disarmed when the Door Contract is triggered, and armed when Door Contact is closed.<
<NNOOTTEE>>
Please refer to Normal Open/Normal Close section below for further detail.
If the device attribute is set to Silent Panic, when the device is activated, the Control Panel will report aSlient Panicalarm without sounding an audible siren.
Personal Attack
If the device attribute is set asPersonal Attack, when the device is activated, the Control Panel will activate aPanic Alarmreport the event
Trigger Scene (Remote Controller Only)
When a Remote Controller set asTrigger Sceneis activated, the Control Panel will execute selected Scene number accord to Home Automation Setting. Please refer to10. Home Automationfor detail.
Permanantly Bypass: Permanantly Bypass will deactivated selected device until you unselect the function. The Control Panel will ignore all signal sent from Permanantly Bypassed device, include Low Battery and Tamper signal.<
<NNOOTTEE>>
For temporary device bypass function, refer to6.6. Temporary Bypass Device.
Latch Report:This function is for Door Contact set to Set/Unset attribute and Remote Controller only. If Latch Report is selected, the Control Panel will send report when the system is armed/disarmed with the Door Contact or Remote Controller.
Normal Open:This function is for for Door Contact using Set/Unset attribute only: If Normal Open is selected, the Door Contact is in Unset condition when opened. When Door Contact is closed, it will change to Set condition and arm the panelIf Normal Open is unselected, Door Contact is in Unset condition when closed. When Door Contact is opened, it will change to Set condition and arm the panel
Group:This option is only available for Power Switch. You can assign multiple Power Switches to a group and control the group together.
Trigger Scene:Select a Home Automation scene to be activated whenever the device is triggered. Please refer to10. Home Automation for detail.For Remote Controller, you must first select “Trigger Scene” in the Remote Controller’s Attribute selection for scene number selection to take effect.
Chime:When Chime function is enabled, if the device is triggered under Disarm mode, the Control Panel will emit a ding-dong Door Chime sound to notify user. If the function is not disabled, no sound will be emitted. Please refer to5.4. Areafor detail.<
<NNOOTTEE>>
To avoid accidental tamper trigger, when you are changing device batteries or moving device locations, you may use the Bypass function to temporarily deactivate the device.