• No results found

DOC.NAME :: TECHNICAL TECHNICAL SPECIFICATION SPECIFICATION FOR FOR LT LT SWITCHGEAR SWITCHGEAR 18.1

In document Tech Specification for LT MCC (Page 32-36)

18.1 StaticStatic // ElectronicElectronic timerstimers of of rangerange (0(0

‐‐

6060 secs)secs) shallshall bebe usedused inin thethe starstar

‐‐

deltadelta starter.

starter.

18.2

18.2 Off Off 

‐‐

delaydelay staticstatic // ElectronicElectronic timerstimers of of (0(0

‐‐

120120 secs)secs) shallshall bebe usedused inin thethe capacitorcapacitor circuits

circuits 18.3

18.3 TimersTimers toto bebe usedused inin thethe lightinglighting circuitscircuits shallshall bebe of of digitaldigital typetype withwith 2424 hrhr setting

setting rangerange andand batterybattery backback

‐‐

upup forfor dawndawn andand duskdusk controlcontrol of of thethe lightinglighting feeders.

feeders.

19.0

19.0 RelaysRelays 19.1

19.1 AllAll protectiveprotective relaysrelays shallshall bebe backback connected,connected, drawdraw outout type,type, suitablesuitable forfor flushflush mounting

mounting andand fittedfitted withwith dustdust tighttight covers.covers. AllAll relaysrelays shallshall bebe mountedmounted onon thethe front

front of of thethe panelpanel andand shallshall bebe specifiedspecified asas perper requirement.requirement. TheThe currentcurrent andand thethe voltage

voltage coilscoils shallshall bebe ratedrated asas specified.specified.

19.2

19.2 AllAll relaysrelays shallshall havehave builtbuilt

‐‐

inin flagflag // indicatorindicator toto indicateindicate operation.operation. AllAll trippingtripping relays

relays shallshall bebe suitablesuitable toto operateoperate onon thethe specifiedspecified DCDC voltage.voltage.

19.3

19.3 AutomaticAutomatic powerpower factorfactor correctioncorrection relayrelay shallshall bebe providedprovided whereverwherever specifiedspecified toto maintain

maintain thethe powerpower factorfactor inin aa particularparticular busbus sectionsection atat prepre

‐‐

setset value.value. ThisThis relayrelay shall

shall bebe of of micromicro processorprocessor basedbased type.type. TheThe numbernumber of of stepssteps toto switchswitch ONON // OFFOFF the

the capacitorcapacitor feedersfeeders shallshall bebe providedprovided inin thisthis relayrelay asas specifiedspecified inin thethe drawings.drawings.

19.4

19.4 TimerTimer relayrelay of of staticstatic typetype withwith 00

‐‐

1sec1sec timetime delaydelay shallshall bebe providedprovided forfor discrepancy

discrepancy function,function, whereverwherever applicable.applicable.

20.0

20.0 MetersMeters andand TransducersTransducers 20.1

20.1 TrivectorTrivector metersmeters shallshall bebe capablecapable of of indicatingindicating allall phasephase instantaneousinstantaneous PARAMETERS

PARAMETERS andand recordingrecording kWH,kWH, kVARHkVARH andand kVAH.kVAH. TheseThese shouldshould bebe suitablesuitable for

for 33 phase,phase, 44 wirewire 5050 HzHz circuitscircuits withwith unbalancedunbalanced loadingloading andand withwith threethree setssets of of  elements

elements connectedconnected toto currentcurrent andand potentialpotential transformerstransformers of of specifiedspecified ratio.ratio.

The

The trivectormetertrivectormeter shallshall bebe digitaldigital type,type, classclass 0.50.5 oror betterbetter withwith communicationcommunication port,port, RS

RS 485485 interface–interface– MODBUSMODBUS

‐‐

RTURTU protocol,protocol, forfor hookinghooking upup toto PCPC // DCS.DCS. TheThe metermeter shall

shall havehave datadata retentionretention facilityfacility inin thethe eventevent of of supplysupply sourcesource failurefailure forfor minimum

minimum oneone monthmonth period.period. TheThe metersmeters shallshall alsoalso bebe capablecapable of of indicatingindicating thethe total

total harmonicharmonic levelslevels upup toto 25th25th harmonicharmonic inin thethe systemsystem forfor currentcurrent asas wellwell asas inin voltage

voltage parameters.parameters.

20.2

20.2 DigitalDigital energyenergy metersmeters shallshall bebe capablecapable of of indicatingindicating allall phasephase INSTANTANEOUSINSTANTANEOUS parameters

parameters andand recordingrecording kWh.kWh. TheseThese shouldshould bebe suitablesuitable forfor 33 phase,phase, 44 wirewire 5050

Hz

Hz circuitscircuits withwith unbalancedunbalanced loadingloading andand withwith threethree setssets of of elementselements connectedconnected to

to currentcurrent andand potentialpotential transformerstransformers of of specifiedspecified ratio.ratio. TheThe energyenergy metermeter shallshall be

be of of digitaldigital type,type, classclass 0.50.5 oror better,better, withwith RSRS 485485 communicationcommunication portport andand suitable

suitable forfor communicatingcommunicating toto ‘Energy‘Energy ManagementManagement System’System’ withwith MODBUSMODBUS

‐‐

RTURTU Protocol.

Protocol. TheThe metermeter shallshall havehave datadata retentionretention facility,facility, asas specified.specified.

20.3

20.3 TestTest terminalterminal blocksblocks shallshall bebe providedprovided inin thethe incomerincomer panelspanels forfor TVMTVM meter.

meter.

20.4

20.4 TheThe analoganalog meters,meters, whereverwherever provided,provided, shallshall bebe of of flushflush mountingmounting typetype withwith square

square patternpattern of of sizesize 144144 mmmm forfor incomerincomer feedersfeeders andand 9696 mmmm dialdial sizesize forfor outgoing

outgoing feeders.feeders. TheThe dialdial shallshall havehave blackblack numeralsnumerals withwith aa whitewhite backgroundbackground and

and shallshall bebe freefree fromfrom parallaxparallax errors.errors. TheThe metersmeters shallshall havehave provisionprovision forfor zerozero adjustment

adjustment outsideoutside thethe cover.cover.

21.0

21.0 CurrentCurrent TransformersTransformers 21.1

21.1 TheThe currentcurrent transformerstransformers shallshall bebe of of barbar primaryprimary woundwound secondarysecondary castcast resinresin type

type andand havehave aa shortshort timetime withstandwithstand ratingrating equalequal toto thatthat of of thethe associatedassociated switchgear

switchgear forfor oneone second.second. ItIt shallshall bebe thethe responsibilityresponsibility of of thethe vendorvendor toto coco

‐‐

ordinate

ordinate thethe burdenburden of of thethe CTsCTs withwith thethe actualactual requirementrequirement of of relays,relays, instruments,

instruments, andand leadsleads etc.,etc., associatedassociated withwith thethe particularparticular CTs.CTs. TheThe minimumminimum requirement

requirement shallshall bebe 55 VAVA burden,burden, accuracyaccuracy classclass 1.01.0 andand anan instrumentinstrument safetysafety factor

factor of of 5.5. CTsCTs withwith 0.50.5 // 0.20.2 accuracyaccuracy classclass shallshall bebe provided,provided, whereverwherever specified.

specified.

21.2

21.2 TheThe CTsCTs shallshall bebe providedprovided withwith thethe following:following:

• TestTest linkslinks inin bothboth secondarysecondary leadsleads toto carrycarry outout phasephase angleangle andand currentcurrent measurement

measurement tests.tests.

• EarthEarth linklink toto whichwhich thethe leadsleads of of thethe CTsCTs shallshall bebe connectedconnected soso asas toto facilitatefacilitate easy

easy measurementmeasurement of of InsulationInsulation ResistanceResistance of of thethe CTs.CTs.

22.0

22.0 PotentialPotential TransformerTransformer 22.1

22.1 TheThe potentialpotential transformertransformer shallshall bebe castcast

‐‐

resinresin insulatedinsulated type.type. InsulationInsulation of of PTPT shall

shall bebe suitablesuitable forfor unearthedunearthed system.system. ItIt shallshall bebe drawdraw outout typetype andand easilyeasily accessible

accessible soso thatthat thethe samesame cancan bebe attendedattended toto oror replacedreplaced whenwhen thethe panelspanels areare in

in serviceservice condition.condition. TheThe PotentialPotential transformerstransformers shallshall bebe of of singlesingle phasephase type,type, nono three

three phasephase typetype shallshall bebe used.used.

22.2

22.2 TheThe potentialpotential transformerstransformers shallshall bebe protectedprotected throughthrough HRCHRC fusesfuses onon primaryprimary side

side andand MCBsMCBs onon secondarysecondary side.side. TheyThey shallshall havehave ratios,ratios, outputsoutputs andand accuraciesaccuracies specified.

specified.

CUSTOMER

CUSTOMER ::

EPC

EPC CONTACTOR CONTACTOR ::

DOC.NAME

DOC.NAME :: TECHNICAL TECHNICAL SPECIFICATION SPECIFICATION FOR FOR LT LT SWITCHGEAR SWITCHGEAR

23.0

23.0 ControlControl TransformersTransformers 23.1

23.1 InIn mainmain PCCPCC panelspanels twotwo numbersnumbers of of controlcontrol transformerstransformers withwith oneone asas standbystandby shall

shall bebe provided.provided. TheThe ratingrating of of thesethese transformerstransformers shallshall bebe sizedsized toto feedfeed toto ACBACB closing

closing coils,coils, ACBACB springspring chargingcharging motormotor coilcoil andand alsoalso forfor underunder voltagevoltage releaserelease of 

of thethe incomersincomers andand tietie feeders.feeders. SeparateSeparate reducantreducant transformerstransformers withwith changeover

changeover arrangementarrangement shallshall alsoalso bebe providedprovided forfor feedingfeeding toto thethe controlcontrol devicedevice requirements

requirements of of thethe panel,panel, panelpanel illumination.illumination.

23.2

23.2 InIn casecase of of MCCMCC panels,panels, minimumminimum twotwo (2)(2) numbersnumbers controlcontrol transformers,transformers, withwith one

one asas standby,standby, shallshall bebe providedprovided inin eacheach switchswitch boardboard forfor meetingmeeting controlcontrol andand auxiliary

auxiliary supplysupply requirementrequirement of of thethe individualindividual modules.modules. RatingRating of of controlcontrol transformer

transformer shallshall bebe sizedsized toto feedfeed allall controlcontrol devicedevice requirementrequirement of of panel,panel, panelpanel illumination

illumination spacespace heaterheater of of motormotor circuits.circuits.

23.3

23.3 TheThe transformerstransformers shallshall bebe providedprovided withwith independentindependent MCCBMCCB // SFUSFU atat primaryprimary with

with arrangementarrangement toto selectselect oneone atat time.time. TheThe transformerstransformers shallshall bebe adequatelyadequately sized

sized toto deliverdeliver 240V240V AC.AC. SupplySupply shallshall bebe protectedprotected againstagainst shortshort circuitscircuits andand over

over loadsloads onon primaryprimary asas wellwell asas secondarysecondary side.side. ControlControl transformers,transformers, SFU,SFU, selector

selector switchesswitches andand contactorscontactors shallshall bebe sizedsized toto feedfeed instrumentinstrument loadsloads andand space

space heaters,heaters, asas specifiedspecified technicaltechnical specification.specification. TheThe controlcontrol transformertransformer change

change overover switchesswitches shallshall bebe of of doordoor mountedmounted type.type. AlsoAlso thethe controlcontrol transformer

transformer shallshall bebe sizedsized toto feedfeed singlesingle phasephase motormotor feeders,feeders, whereverwherever specified

specified 24.0

24.0 PushPush Buttons,Buttons, ControlControl SwitchesSwitches andand PilotPilot LampsLamps 24.1

24.1 TheThe pushpush buttonsbuttons shallshall bebe of of shroudedshrouded typetype withwith actuatoractuator providedprovided withwith escutcheon

escutcheon platesplates markedmarked withwith itsits functionfunction onon it.it.

24.2

24.2 ControlControl switchesswitches shallshall bebe of of thethe heavyheavy dutyduty rotaryrotary typetype withwith namename platesplates clearlyclearly marked

marked toto showshow thethe operation.operation. TheyThey shallshall bebe semisemi

‐‐

flushedflushed mountingmounting withwith onlyonly the

the frontfront plateplate andand operatingoperating handlehandle projecting.projecting. CircuitCircuit breakerbreaker controlcontrol switchesswitches shall

shall bebe of of thethe springspring returnreturn toto neutralneutral type,type, whilewhile locallocal // remoteremote selectorselector switches

switches andand instrumentinstrument selectorselector switchesswitches shallshall bebe of of thethe staystay

‐‐

putput type.type.

24.3

24.3 TheThe indicatingindicating lampslamps shallshall bebe of of clustercluster LEDLED typetype of of lowlow wattwatt consumption.consumption. TheyThey shall

shall bebe providedprovided withwith seriesseries resistors.resistors.

25.0

25.0 InterconnectionsInterconnections

25.1

25.1 AllAll switchgearswitchgear cubiclescubicles shallshall bebe suppliedsupplied completelycompletely wiredwired internallyinternally toto equipment

equipment andand terminalterminal blocksblocks andand readyready forfor PURCHASER'sPURCHASER's externalexternal connections

connections atat thethe outgoingoutgoing terminalterminal blocks.blocks. InterconnectionInterconnection betweenbetween allall compartments

compartments andand marshallingmarshalling cabinetscabinets shallshall alsoalso bebe completed.completed.

25.2

25.2 TheThe wiringwiring shallshall bebe completecomplete inin allall respectsrespects soso asas toto ensureensure properproper functioningfunctioning of 

of control,control, protectionprotection andand interlockinginterlocking schemes.schemes.

25.3

25.3 PowerPower interconnectionsinterconnections insideinside thethe panelpanel shallshall bebe donedone withwith 650/1100650/1100 VV gradegrade single

single corecore PVCPVC insulatedinsulated coppercopper conductorconductor upup toto 6363 AmpsAmps ratingrating andand aboveabove 6363 Amps

Amps ratingrating byby coppercopper flats.flats. WhereverWherever coppercopper withwith CopperCopper dirt’sdirt’s areare mademade bibi

‐‐

metallic

metallic connectorsconnectors // contactorscontactors shouldshould bebe used.used. ControlControl wiringwiring shallshall bebe donedone with

with 650/1100650/1100 VV gradegrade PVCPVC singlesingle corecore coppercopper conductorconductor of of minimumminimum crosscross section

section 2.52.5 Sq.mmSq.mm forfor CTCT wiringwiring andand 1.51.5 Sq.mm.Sq.mm. forfor others.others.

25.4

25.4 TheThe cablingcabling chamberchamber of of adequateadequate sizesize forfor accommodation,accommodation, supportsupport andand termination

termination of of coppercopper cablescables shallshall bebe providedprovided atat thethe rear.rear. FacilityFacility toto extendextend cabling

cabling areaarea byby additionaladditional cablecable chamberchamber shallshall bebe preferred.preferred.

25.5

25.5 AllAll wiringswirings andand cablescables atat thethe terminationsterminations atat thethe switchboardswitchboard shallshall havehave distinctdistinct marking

marking byby meansmeans of of ferrulesferrules withwith lettersletters // numeralsnumerals printedprinted correspondingcorresponding toto the

the wiringwiring diagramdiagram toto bebe furnishedfurnished byby thethe successfulsuccessful SUPPLIER.SUPPLIER.

26.0

26.0 TerminalTerminal BlocksBlocks 26.1

26.1 TheThe terminalterminal blocksblocks providedprovided inin thethe switchboardswitchboard shallshall bebe mountedmounted verticallyvertically near

near thethe bottombottom sideside of of eacheach modulemodule unit,unit, inin thethe cablecable chamberchamber atat aa slightlyslightly upward

upward angle,angle, toto provideprovide clearclear andand easyeasy accessaccess toto thethe terminals.terminals.

26.2

26.2 EachEach wirewire atat terminalterminal blocksblocks shallshall bebe distinctlydistinctly identifiedidentified withwith appropriateappropriate number

number // letterletter ferrulesferrules atat eacheach endend inin accordanceaccordance withwith thethe schematics.schematics.

26.3

26.3 WiringWiring toto thethe doordoor shallshall bebe donedone byby flexibleflexible cablecable andand thethe cablescables shallshall bebe bunched,

bunched, sleevedsleeved andand cleatedcleated soso thatthat nono mechanicalmechanical damagedamage cancan occuroccur toto thethe cables

cables whenwhen thethe doordoor swings.swings.

26.4

26.4 NotNot moremore thanthan 22 wireswires shallshall bebe terminatedterminated atat oneone controlcontrol terminal.terminal.

26.5

26.5 AllAll terminationsterminations shallshall bebe of of adequateadequate currentcurrent ratingrating andand sizesize toto suitsuit individualindividual feeder

feeder requirement.requirement.

CUSTOMER

CUSTOMER ::

EPC

EPC CONTACTOR CONTACTOR ::

DOC.NAME

DOC.NAME :: TECHNICAL TECHNICAL SPECIFICATION SPECIFICATION FOR FOR LT LT SWITCHGEAR SWITCHGEAR

In document Tech Specification for LT MCC (Page 32-36)

Related documents