EFI error and warning messages are displayed on the console as part of the boot process. They can also be retrieved using the EFI info warnings command.Table 4-5lists possible error messages.
Table 4-5 EFI Error and Warning Messages
Description/Solution Message
Error Number
Incorrect I/O configuration. Contact the HP Support Center for assistance.
Insufficient resources to assign to one or more I/O devices
2
Incorrect I/O configuration. Contact the HP Support Center for assistance.
Unexpected hardware I/O configuration 4
Update BMC firmware. No BMC installed on the platform
7
Check system logs for errors. Replace the system board.
BMC cannot be accessed 8
Communication with the BMC failed. Check power. Replace the system board.
One or more BMC ports failed 9
Clear the SEL. BMC system event log is full
10
Contact the HP Support Center for assistance. Platform silicon-controlled rectifier (SCR) is bad
11
Communication with the BMC failed. Replace the system board.
Set time to BMC SEL failed 12
Communication with the BMC failed. Replace the system board.
SEL get info failed 13
Communication with the BMC failed. Replace the system board.
Initial BMC SEL event failed 14
Communication with the BMC failed. Replace the system board.
Update of BMC buffered data failed 15
Communication with the BMC failed. Replace the system board.
All advanced configuration and power interface (ACPI) BMC ports bad
16
Communication with the BMC failed. Replace the system board.
Read error on BMC token 17
Table 4-5 EFI Error and Warning Messages (continued)
Description/Solution Message
Error Number
Communication with the BMC failed. Replace the system board.
Error writing BMC token on download 19
Communication with the BMC failed. Replace the system board.
Non-volatile Memory (NVM) token access error 20
Communication with the BMC failed. Replace the system board.
BMC token write error during NVM write through
21
Communication with the BMC failed. Replace the system board.
Error reading BMC token on upload to NVM 22
Communication with the BMC failed. Replace the system board.
Error reading BMC first boot token 23
Reflash firmware. Primary field interoperability testing (FIT) failed
24
Reflash firmware. Secondary FIT failed
25
Reflash firmware. Processor abstraction layer (PAL) A warning;
One copy of PAL is bad 26
Update firmware. PAL A warning; PAL is not compatible with at
least 1 CPU 27
Reseat DIMMs; if error persists replace bad DIMMs.
Memory errors detected and Page Deallocation Table (PDT) is disabled
28
Information only, no action required. Memory required reinterleave to get a good
page 0 30
Information only, no action required. One or more ranks have chipspare disabled
31
Check memory installation. Match DIMM part numbers within each quad.
One or more memory ranks are mismatched or deallocated
33
Check memory installation. DIMMs must be installed with smallest capacity in the first quad, Memory deallocated because of a loading error
34
an equal or larger capacity in the second quad, and an equal or larger capacity in the third quad. Check memory installation. DIMMs must be installed with smallest capacity in the first quad, Memory load order error
35
an equal or larger capacity in the second quad, and an equal or largest capacity in the third quad. Clear with pdt clear command in the EFI Shell. The PDT is full
36
Check processor installation. Verify installation and that identical processors have been installed. At least one CPU has bad fixed core ratio
37
Processor failure. Verify installation and replace processor. Contact the HP Support Center for assistance.
All CPUs were slated for compatibility deconfiguration
38
Check processor installation and match CPU part numbers. CPUs must be identical.
Incompatible CPUs detected 39
Check processor installation. Match CPU part numbers. CPUs must be identical. This always causes a stopboot.
CPUs installed with mixed cache sizes 40
Check processor installation and match CPU part numbers. CPUs must be identical.
CPUs installed with mixed steppings 41
Check processor installation and match CPU part numbers. CPUs must be identical.
All CPUs are overclocked 42
Table 4-5 EFI Error and Warning Messages (continued)
Description/Solution Message
Error Number
Check processor installation and match CPU part numbers. CPUs must be identical.
At least one (1) CPU is overclocked 43
Check processor installation and match CPU part numbers. CPUs must be identical.
Monarch changed to lowest stepping CPU 44
Reload processors in the correct order. CPUs loaded in wrong order
46
Information only, no action required. SAL NVM cleared
48
Information only, no action required. EFI NVM cleared
49
Reboot the server. If the error message is repeated, contact the HP Support Center for assistance. EFI NVM failed
50
Check and verify processor installation. Replace the processor that was deconfigured.
CPU deconfigured by SAL_B 51
One or more firmware components (FW, BMC, MP) is out of date. Update firmware as appropriate.
A ROM revision is inconsistent with FIT or REVBLOCK
52
Contact the HP Support Center for assistance. Error building S MBIOS
53
Contact the HP Support Center for assistance. Failure constructing the EFI Memory Data Table
(MDT) 54
Update with the sysset command. UUID error
55
Reboot the server. If the error message is repeated, replace the failing processor.
Error reading CPU S MBUS information ROM 56
Replace the CRU that was reported. If the error message is repeated, contact the HP Support Center for assistance.
Error accessing CRU information 57
Replace the CRU that was reported. If the error message is repeated, contact the HP Support Center for assistance.
Checksum error accessing CRU information 58
Contact the HP Support Center for assistance. CRU information version error
59