EFI Error and Warning Messages

EFI error and warning messages are displayed on the console as part of the boot process. They can also be retrieved using the EFI info warnings command.Table 4-5lists possible error messages.

Table 4-5 EFI Error and Warning Messages

Description/Solution Message

Error Number

Incorrect I/O configuration. Contact the HP Support Center for assistance.

Insufficient resources to assign to one or more I/O devices

2

Incorrect I/O configuration. Contact the HP Support Center for assistance.

Unexpected hardware I/O configuration 4

Update BMC firmware. No BMC installed on the platform

7

Check system logs for errors. Replace the system board.

BMC cannot be accessed 8

Communication with the BMC failed. Check power. Replace the system board.

One or more BMC ports failed 9

Clear the SEL. BMC system event log is full

10

Contact the HP Support Center for assistance. Platform silicon-controlled rectifier (SCR) is bad

11

Communication with the BMC failed. Replace the system board.

Set time to BMC SEL failed 12

Communication with the BMC failed. Replace the system board.

SEL get info failed 13

Communication with the BMC failed. Replace the system board.

Initial BMC SEL event failed 14

Communication with the BMC failed. Replace the system board.

Update of BMC buffered data failed 15

Communication with the BMC failed. Replace the system board.

All advanced configuration and power interface (ACPI) BMC ports bad

16

Communication with the BMC failed. Replace the system board.

Read error on BMC token 17

Table 4-5 EFI Error and Warning Messages (continued)

Description/Solution Message

Error Number

Communication with the BMC failed. Replace the system board.

Error writing BMC token on download 19

Communication with the BMC failed. Replace the system board.

Non-volatile Memory (NVM) token access error 20

Communication with the BMC failed. Replace the system board.

BMC token write error during NVM write through

21

Communication with the BMC failed. Replace the system board.

Error reading BMC token on upload to NVM 22

Communication with the BMC failed. Replace the system board.

Error reading BMC first boot token 23

Reflash firmware. Primary field interoperability testing (FIT) failed

24

Reflash firmware. Secondary FIT failed

25

Reflash firmware. Processor abstraction layer (PAL) A warning;

One copy of PAL is bad 26

Update firmware. PAL A warning; PAL is not compatible with at

least 1 CPU 27

Reseat DIMMs; if error persists replace bad DIMMs.

Memory errors detected and Page Deallocation Table (PDT) is disabled

28

Information only, no action required. Memory required reinterleave to get a good

page 0 30

Information only, no action required. One or more ranks have chipspare disabled

31

Check memory installation. Match DIMM part numbers within each quad.

One or more memory ranks are mismatched or deallocated

33

Check memory installation. DIMMs must be installed with smallest capacity in the first quad, Memory deallocated because of a loading error

34

an equal or larger capacity in the second quad, and an equal or larger capacity in the third quad. Check memory installation. DIMMs must be installed with smallest capacity in the first quad, Memory load order error

35

an equal or larger capacity in the second quad, and an equal or largest capacity in the third quad. Clear with pdt clear command in the EFI Shell. The PDT is full

36

Check processor installation. Verify installation and that identical processors have been installed. At least one CPU has bad fixed core ratio

37

Processor failure. Verify installation and replace processor. Contact the HP Support Center for assistance.

All CPUs were slated for compatibility deconfiguration

38

Check processor installation and match CPU part numbers. CPUs must be identical.

Incompatible CPUs detected 39

Check processor installation. Match CPU part numbers. CPUs must be identical. This always causes a stopboot.

CPUs installed with mixed cache sizes 40

Check processor installation and match CPU part numbers. CPUs must be identical.

CPUs installed with mixed steppings 41

Check processor installation and match CPU part numbers. CPUs must be identical.

All CPUs are overclocked 42

Table 4-5 EFI Error and Warning Messages (continued)

Description/Solution Message

Error Number

Check processor installation and match CPU part numbers. CPUs must be identical.

At least one (1) CPU is overclocked 43

Check processor installation and match CPU part numbers. CPUs must be identical.

Monarch changed to lowest stepping CPU 44

Reload processors in the correct order. CPUs loaded in wrong order

46

Information only, no action required. SAL NVM cleared

48

Information only, no action required. EFI NVM cleared

49

Reboot the server. If the error message is repeated, contact the HP Support Center for assistance. EFI NVM failed

50

Check and verify processor installation. Replace the processor that was deconfigured.

CPU deconfigured by SAL_B 51

One or more firmware components (FW, BMC, MP) is out of date. Update firmware as appropriate.

A ROM revision is inconsistent with FIT or REVBLOCK

52

Contact the HP Support Center for assistance. Error building S MBIOS

53

Contact the HP Support Center for assistance. Failure constructing the EFI Memory Data Table

(MDT) 54

Update with the sysset command. UUID error

55

Reboot the server. If the error message is repeated, replace the failing processor.

Error reading CPU S MBUS information ROM 56

Replace the CRU that was reported. If the error message is repeated, contact the HP Support Center for assistance.

Error accessing CRU information 57

Replace the CRU that was reported. If the error message is repeated, contact the HP Support Center for assistance.

Checksum error accessing CRU information 58

Contact the HP Support Center for assistance. CRU information version error

59