• No results found

EQA MODIFY MOBILE ALLOCATION FRE- FRE-QUENCY LIST USAGE PARAMETERS

In document Zeqx Mml Description (Page 47-52)

Function With this command you define the mobile allocation usage of the BTS.

Parameters BTS identification, BTS name: mobile allocation frequency list, underlay mobile alloca-tion frequency list <opalloca-tion>, MAIO offset, underlay MAIO offset <opalloca-tion>, MAIO step

<option>, underlay MAIO step <option>, DFCA mobile allocation lists <option>, DFCA operation type <option>, DFCA unsynchronized mode MA list <option>;

Syntax EQA : ( BTS = <BTS identification> | NAME = <BTS name> :

( MAL = <mobile allocation frequency list> |

UMAL = <underlay mobile allocation frequency list>

<option> |

MO = <MAIO offset> |

UMO = <underlay MAIO offset> <option> | MS = <MAIO step> <option> |

UMS = <underlay MAIO step> <option> |

DMAL = <DFCA mobile allocation frequency lists>

<option> |

OPE = <DFCA operation type> <option> |

DUMAL = <DFCA unsynchronized mode MA frequency list> <option> ) ... ;

Parameter explana-tions

BTS identification BTS = decimal number

With this parameter you identify the BTS with its number. The value range depends on the BSC hardware configuration and the corresponding options.

You can enter several values at the same time by using the grouping characters & and

&& when attaching or detaching the same DFCA mobile allocation frequency list to several BTSs. The value ALL attaches or detaches the same DFCA mobile allocation frequency list to or from all DFCA BTSs.

If you give this parameter, you cannot give the parameter NAME.

BTS name

NAME = text string

With this parameter you identify the BTS with its name. The name can contain 1 to 15 characters.

You can enter several values at the same time by using the grouping character & when you attach or detach the same DFCA mobile allocation frequency list to several BTSs.

If you give this parameter, you cannot give the parameter BTS.

mobile allocation frequency list

EQ - Base Transceiver Station Handling in BSC EQA MODIFY MOBILE ALLOCATION FREQUENCY

LIST USAGE PARAMETERS

The values range from 0 to 4200. Use value 0 to detach the BTS from the mobile allo-cation frequency list.

You can modify this parameter only when the BTS is LOCKED or the overlay hopping mode is not RF hopping.

underlay mobile allocation frequency list <option>

UMAL = decimal number

With this parameter you define the mobile allocation frequency list to which the BTS's underlay layer will be attached.

The values range from 0 to 4200. Use value 0 to detach the BTS's underlay layer from a mobile allocation frequency list.

You can modify this parameter only when the BTS is LOCKED or the underlay hopping mode is not RF hopping.

MAIO offset

MO = decimal number

With this parameter you set the lowest MAIO (Mobile Allocation Index Offset) value per sector. The values range from 0 to 62.

You can modify this parameter only when the BTS is LOCKED, underlay TRXs are LOCKED, or the overlay hopping mode is not RF hopping.

underlay MAIO offset <option>

UMO = decimal number

With this parameter you set the lowest MAIO value of the underlay layer per sector.

The values range from 0 to 62.

You can modify this parameter only when the BTS is LOCKED, overlay TRXs are LOCKED, or the underlay hopping mode is not RF hopping.

MAIO step <option>

MS = decimal number

With this parameter you choose the MAIOs not to be allocated successively for the cell, but for instance every second or every third value. The values range from 1 to 62.

You can modify this parameter only when the BTS is LOCKED, underlay TRXs are LOCKED, or the overlay hopping mode is not RF hopping.

underlay MAIO step <option>

UMS = decimal number

With this parameter you choose the MAIOs of the underlay layer not to be allocated suc-cessively for the cell, but for instance every second or every third value.

The values range from 1 to 62.

You can modify this parameter only when the BTS is LOCKED, overlay TRXs are LOCKED, or the underlay hopping mode is not RF hopping.

DFCA mobile allocation frequency lists <option>

DMAL = decimal number

With this parameter you define the DFCA mobile allocation frequency lists that will be attached to the BTS.

EQ - Base Transceiver Station Handling in BSC EQA MODIFY MOBILE ALLOCATION FREQUENCY LIST USAGE PARAMETERS

The values range from 1 to 64.

You can enter several values at the same time by using the grouping characters & and

&&. If more than one BTS identification or name has been given, grouping characters cannot be used.

DFCA MA list operation <option>

With this parameter you add or remove valid DFCA mobile allocation frequency list(s) to/from the BTS.

If you give this parameter, you must also give the DMAL parameter.

DFCA unsynchronized mode MA frequency list <option>

DUMAL = decimal number

With this parameter you define the DFCA unsynchronised mode MA list. The MA list is to be used in the DFCA TRXs if a BTS in 'DFCA hopping' mode loses synchronisation or BSC-BSC connection. This is a reference to any existing normal (non-DFCA) MA list defined in the BSC.

The values range from 0 to 4200. Use value 0 to detach the BTS from the DFCA unsyn-chronised mode MA frequency list.

Examples 1. Attach BTS-8 to mobile allocation frequency list 3 and set MAIO offset to 2.

ZEQA:BTS=8:MAL=3,MO=2;

2. Detach BTS CENTRUM1 from the mobile allocation frequency list.

ZEQA:NAME=CENTRUM1:MAL=0;

Additional informa-tion

(trx-1) * ms + mo < fma where

TRX= the number of underlay/overlay unlocked hopping TRXs in the cell ms= underlay/overlay MAIO step

mo= underlay/overlay MAIO offset

fma= the number of frequencies in the associated underlay/overlay mobile allocation frequency list

Execution printouts The execution printout of the command ZEQA:BTS=16:MAL=10,MO=3;

is:

Parameter Value Explanation

OPE = A Add DFCA mobile

allocation frequency list(s) to the BTS.

R Remove DFCA mobile

allocation frequency list(s) from the BTS.

EQ - Base Transceiver Station Handling in BSC EQA MODIFY MOBILE ALLOCATION FREQUENCY

LIST USAGE PARAMETERS

MOBILE ALLOCATION FREQUENCY LIST USAGE PARAMETER MODIFY COMPLETED:

==================================================================

SEG-0002 BIGCENTRUM002

BCF-0002 BTS-0016 CENTRUM16

---BTS ADMINISTRATIVE STATE ... LOCKED BTS OPERATIONAL STATE ... BL-USR

MOBILE ALLOCATION FREQUENCY LIST...(MAL).... 10 UNDERLAY MA FREQUENCY LIST...(UMAL)... DFCA MOBILE ALLOCATION FREQUENCY LIST (S)..(DMAL)... CS: PS: DFCA UNSYNCHRONIZED MODE MA FREQ LIST...(DUMAL)..

-MAIO OFFSET...(MO)... 3 UNDERLAY MAIO OFFSET...(UMO).... 0 MAIO STEP...(MS)... 1 UNDERLAY MAIO STEP...(UMS).... 1

BSC DATABASE UPDATED

COMMAND EXECUTED

The execution printout of the command ZEQA:BTS=50:MAL=0;

is:

DX 200 DX220-LAB 2007-11-29 01:58:00

MOBILE ALLOCATION FREQUENCY LIST USAGE PARAMETER MODIFY COMPLETED:

==================================================================

SEG-0001 BIGCENTRUM1

BCF-0001 BTS-0050 CENTRUM50

---BTS ADMINISTRATIVE STATE ... LOCKED BTS OPERATIONAL STATE ... BL-USR

MOBILE ALLOCATION FREQUENCY LIST...(MAL).... UNDERLAY MA FREQUENCY LIST...(UMAL)... DFCA MOBILE ALLOCATION FREQUENCY LIST (S)..(DMAL)... CS: PS: DFCA UNSYNCHRONIZED MODE MA FREQ LIST...(DUMAL)..

-MAIO OFFSET...(MO)... 3 UNDERLAY MAIO OFFSET...(UMO).... 0 MAIO STEP...(MS)... 1 UNDERLAY MAIO STEP...(UMS).... 1

BSC DATABASE UPDATED

EQ - Base Transceiver Station Handling in BSC EQA MODIFY MOBILE ALLOCATION FREQUENCY LIST USAGE PARAMETERS

COMMAND EXECUTED Semantic error messages

If an error occurs, the general semantic error messages of the MML commands are output. For more information, see General Notice Messages of MML Session.

Execution error messages

If an error occurs, the general execution error messages of the MML commands are output. For more information, see Radio Network Administration and General Error Messages of System.

EQ - Base Transceiver Station Handling in BSC EQB MODIFY BCCH FREQUENCY LIST USAGE

PA-RAMETERS <option>

EQB MODIFY BCCH FREQUENCY LIST

In document Zeqx Mml Description (Page 47-52)