EQUIPMENT DATA

In document TM 10-5419-206-13 FORCE PROVIDER (Page 61-69)

EQUIPMENT DATA

The following tables list equipment/site data by subsystem, followed by a module data summary. Data pertaining to Modification Systems is listed separately.

Transportation/Storage Container Subsystem

Number of Sites: As required Area: N/A

Capacity: N/A

Power Requirements: N/A Potable Water Usage: N/A Graywater Produced: N/A Blackwater Produced: N/A Fuel Requirements: N/A

Table 1. Transportation/Storage Container Subsystem Shipping Configuration. Container/

Item Type Quantity Cube (each)

Empty Weight (each) 1A TRICON 15 413.3 ft3 2,700 lbs 1B TRICON 15 413.3 ft3 2,700 lbs 1C TRICON 1 413.3 ft3 2,700 lbs 1D TRICON 1 413.3 ft3 2,700 lbs 2A TRICON 1 413.3 ft3 2,700 lbs 2B TRICON 1 413.3 ft3 2,700 lbs 2C ISO 1 1,280 ft3 5,510 lbs 3A ISO 4 1,280 ft3 4,960 lbs 3B TRICON 2 413.3 ft3 2,700 lbs 4A ISO 2 1,280 ft3 5,250 lbs 4B TRICON 1 413.3 ft3 2,700 lbs 4C TRICON 1 413.3 ft3 2,700 lbs 4D TRICON 2 413.3 ft3 2,700 lbs 4E TRICON 1 413.3 ft3 2,700 lbs 5A TRICON 2 413.3 ft3 2,700 lbs 5B TRICON 1 413.3 ft3 2,700 lbs 7B TRICON 1 413.3 ft3 2,700 lbs 7C TRICON 1 413.3 ft3 2,700 lbs 8A ISO 1 1,280 ft3 4,960 lbs 8B TRICON 1 413.3 ft3 2,700 lbs 8C TRICON 1 413.3 ft3 2,700 lbs 8D TRICON 1 413.3 ft3 2,700 lbs 10A ISO 1 1,280 ft3 4,960 lbs 10B TRICON 1 413.3 ft3 2,700 lbs 10C TRICON 1 413.3 ft3 2,700 lbs 10D TRICON 1 413.3 ft3 2,700 lbs 10E TRICON 2 413.3 ft3 2,700 lbs 10F TRICON 1 413.3 ft3 2,700 lbs 10G TRICON 1 413.3 ft3 2,700 lbs 10I TRICON 1 413.3 ft3 2,700 lbs 10J TRICON 1 413.3 ft3 2,700 lbs 10K TRICON 1 413.3 ft3 2,700 lbs 10L TRICON 1 413.3 ft3 2,700 lbs

TM 10-5419-206-13 0019 00

Table 1. Transportation/Storage Subsystem Shipping Configuration – Continued. Container/

Item Type Quantity Cube (each)

Empty Weight (each) 10M TRICON 1 413.3 ft3 2,700 lbs 10N TRICON 1 413.3 ft3 2,700 lbs 10P TRICON 1 413.3 ft3 2,700 lbs 11A TRICON 1 413.3 ft3 2,700 lbs 11B TRICON 1 413.3 ft3 2,700 lbs 11C TRICON 1 413.3 ft3 2,700 lbs 11D ISO 1 1,280 ft3 4,960 lbs 11G TRICON 1 413.3 ft3 2,700 lbs 11H TRICON 1 413.3 ft3 2,700 lbs 12A TRICON 2 413.3 ft3 2,700 lbs 12B TRICON 1 413.3 ft3 2,700 lbs 12C TRICON 5 413.3 ft3 2,700 lbs 12E TRICON 1 413.3 ft3 2,700 lbs 12F TRICON 3 413.3 ft3 2,700 lbs

8B Container, Reusable, Bulk

Equipment, Commercial 1 See Note See Note 7B (2), 11C (2) Container, Reusable, Bulk

Equipment, Half Size 4 See Note See Note 5A-1 (2), 5A-

2 (2), 8C (2)

Container, Reusable, Bulk

Equipment, Medium 6 See Note See Note 5B (2), 11A (1)

7C (3), 1B (3)

Container, Reusable, Bulk

Equipment, Small 9 See Note See Note

8B (2)

Container, Reusable, Bulk Equipment, Half Size, General Purpose

2 See Note See Note

TOTAL 112 54,956.60 ft3 45,864.00 lbs

Note: The cube and weight of each reusable container are included in the respective subsystem TRICON data.

Billeting Subsystem

Number of Sites: 41/2

Area: Approximately 9,000-ft2/site (7 each 20-foot x 32-foot TEMPER/site spaced 20 feet apart) Capacity: 550 soldiers, 110 Support personnel

Power Requirements: 208VAC/3 phase/60 Hz, 12 kW per TEMPER (avg.) 84kW/site Potable Water Usage: N/A

Graywater Produced: N/A Blackwater Produced: N/A

Fuel Requirements: MSCW configuration – ASH Heaters (32units/0.5Gal/hr/24 Hours) = 384 Gallon/day

Table 2. Billeting Subsystem Shipping Configuration. Container/

Item Type Quantity Cube (each) Weight (each)

1A TRICON 15 413.3 ft3 7,950 lbs 1B TRICON 15 413.3 ft3 5,450 lbs 1C TRICON 1 413.3 ft3 4,260 lbs 1D TRICON 1 413.3 ft3 9,110 lbs

TM 10-5419-206-13 0019 00

Laundry Subsystem

Number of Sites: 1

Area: Approximately 5,000-ft2/site Capacity: 200 lbs laundry/hour

Power Requirements: 208VAC/3 phase/60 Hz, 100 kW Potable Water Usage: 5,200 Gallon/day

Graywater Produced: 5,200 Gallon/day Blackwater Produced: N/A

Fuel Requirements: M-80 Water Heater (1unit/2.5Gal/hr/24 Hours) = 60 Gallon/day

Additional Fuel Requirements for MSCW: ASH Heater (1unit/0.5Gal/hr/24 Hours) = 12 Gallon/day

Table 3. Laundry Subsystem Shipping Configuration. Container/

Item Type Quantity Cube (each) Weight (each)

2A TRICON 1 413.3 ft3 5,850 lbs 2B TRICON 1 413.3 ft3 4,250 lbs 2C ISO 1 1,280 ft3 13,530 lbs TOTAL 3 2,106.6 ft3 23,630 lbs Latrine Subsystem Number of Sites: 2 Area: 6,530-ft2/site Capacity: 300 soldiers/site

Power Requirements: 208VAC/3 phase/60 Hz, 40kW/site Potable Water Usage: 3000 Gallon/day

Graywater Produced: N/A

Blackwater Produced: 3,780 Gal/day (6.3 Gallon/day/soldier) Fuel Requirements: 2 WWET/T, 4Gal/hr = 40 Gallon/day

Additional Fuel Requirements for MSCW: ASH Heater (2units/0.5Gal/hr/24 Hours) = 24 Gallon/day

Table 4. Latrine Subsystem Shipping Configuration. Container/

Item Type Quantity Cube (each) Weight (each)

3A (-1, -2) ISO 2 1,280 ft3 10,860 lbs 3A (-3, -4) ISO 2 1,280 ft3 9,900 lbs 3B TRICON 2 413.3 ft3 5,260 lbs WWET/T Trailer 2 1,224 ft3 7,920 lbs (Empty)

TOTAL 6 8,394.6 ft3 67,880 lbs

Shower Subsystem

Number of Sites: 2 Area: 6,970-ft2/site

Capacity: 275 soldiers/site

Power Requirements: 208VAC/3 phase/60 Hz, 27.5kW/site Potable Water Usage: 11,000 Gallon/day

Graywater Produced: 11,000 Gallon/day Blackwater Produced: N/A

Fuel Requirements: M-80 Water Heater (2units/2.5Gal/hr/24 Hours) = 120 Gallon/day

TM 10-5419-206-13 0019 00

Table 5. Shower Subsystem Shipping Configuration. Container/

Item Type Quantity Cube (each) Weight (each)

4A ISO 2 1,280 ft 3 9,500 lbs 4B TRICON 1 413.3 ft3 7,120 lbs 4C TRICON 1 413.3 ft3 5,420 lbs 4D TRICON 2 413.3 ft3 4,160 lbs 4E TRICON 1 413.3 ft3 3,990 lbs TOTAL 7 13,225.6 ft3 43,850 lbs

Potable Water Distribution Subsystem

Number of Sites: 4 Area: 6,530-ft2/site

Capacity: 20,000 Gallons potable water storage/site Power Requirements: 208VAC/3 phase/60 Hz, 1.5kW/site

Additional Power Requirements for MSCW configuration: (2 heat traced hoses/3.4kW each) Potable Water Usage: N/A

Graywater Produced: N/A Blackwater Produced: N/A Fuel Requirements: N/A

Additional Fuel Requirements for MSCW: ASH Heaters (4units/0.5Gal/hr/24 Hours) = 48 Gallon/day

Table 6. Potable Water Distribution Subsystem Shipping Configuration.

Container/ Item Type Quantity Cube (each) Weight (each)

5A TRICON 2 413.3 ft3 7,470 lbs 5B TRICON 1 413.3 ft3 5,130 lbs 400 Gallon Tank Trailer 4 625 ft3 2,800 lbs

TOTAL 7 3,739 ft3 31,270 lbs

Fuel Storage and Distribution Subsystem

Diesel/JP8 Storage and Distribution Number of Sites: 1

Area: 2,500-ft2/site

Capacity: 20,000 Gallon Diesel/JP8 storage, 2,517 Gallon/day Power Requirements: 208V/3Phase, 1.5 kW

Fuel Requirements: N/A

Shipping Configuration: Container 7B (see Table 7)

Power Generation Fuel Stores (Used when Modification System Power Generation is deployed) Number of Sites: 9

Area: 500-ft2/site

Capacity: 500 Gallon Diesel/JP8 storage per site Power Requirements: N/A

Fuel Requirements: N/A

TM 10-5419-206-13 0019 00

Fuel Storage and Distribution Subsystem – Continued.

Prime Power Fuel Storage (Used when Modification System Prime Power is deployed) Number of Sites: 1

Area: 2,500-ft2/site

Capacity: 20,000 Gallon Diesel/JP8 fuel storage Power Requirements: N/A

Fuel Requirements: N/A

Shipping configuration: Container 7C (see Table 7)

Table 7. Fuel Storage and Distribution Subsystem Shipping Configuration.

Container/ Item Type Quantity Cube (each) Weight (each)

7B TRICON 1 413.3 ft3 5,390 lbs 7C TRICON 1 413.3 ft3 5,420 lbs 21B* TRICON (1) (413.3 ft3) (8,040 lbs)

TOTAL 2 826.6 ft3 10,810 lbs

*Shipped with Modification System Power Generation

Wastewater Collection Subsystem

Number of Sites: 1 (When set up in the MSCW Configuration: 2) Area: 10,000-ft2/site (5,000-ft2/site in MSCW configuration)

Capacity: 40,000 Gallons graywater storage (average 17,575 Gallons/day collected) Power Requirements: 208VAC/3 phase/60 Hz, 1.5kW/site

Additional Power Requirements for MSCW Configuration: (2 heat traced hoses/3.4kW each) Potable Water Usage: N/A

Graywater Produced: N/A Blackwater Produced: N/A

Fuel Requirements: 1 Gallon/day, DF-2 or JP8 (for tank draining pumps/site)

Additional Fuel Requirements for MSCW configuration: ASH Heaters (4units/0.5Gal/hr/24 Hours) = 48 Gallon/day

Table 8. Wastewater Collection Subsystem Shipping Configuration. Container/

Item Type Quantity Cube (each) Weight (each)

8A ISO 1 1,280 ft 3 12,320 lbs 8B TRICON 1 413.3 ft3 5,950 lbs 8C TRICON 1 413.3 ft3 5,570 lbs 8D TRICON 1 413.3 ft3 5,570 lbs

TM 10-5419-206-13 0019 00

Food Service Subsystem

Number of Sites: 1 Area: 28,000-ft2/site

Capacity: 660 Type A or B meals, three times daily

Power Requirements: 208VAC/3 phase/60 Hz, 120kW/site Potable Water Usage: 1,925 Gallon/day

Graywater Produced: 1,375 Gallon/day

Fuel Requirements: M-80 Water Heater (1unit/2.5Gal/hr/24 Hours) = 60 Gallon/day

Additional Fuel Requirements for MSCW: ASH Heater (7units/0.5Gal/hr/24 Hours) = 84 Gallon/day

Table 9. Food Service Subsystem Shipping Configuration. Container/

Item Type Quantity Cube (each) Weight (each)

10A ISO 1 1,280 ft 3 10,020 lbs 10B TRICON 1 413.3 ft3 6,300 lbs 10C TRICON 1 413.3 ft3 4,570 lbs 10D TRICON 1 413.3 ft3 5,420 lbs 10E TRICON 2 413.3 ft3 5,340 lbs 10F TRICON 1 413.3 ft3 7,180 lbs 10G TRICON 1 413.3 ft3 6,580 lbs 10I TRICON 1 413.3 ft3 5,530 lbs 10J TRICON 1 413.3 ft3 4,660 lbs

Table 9. Food Service Subsystem Shipping Configuration – Continued. Container/

Item

Type Quantity Cube (each) Weight (each)

10K TRICON 1 413.3 ft3 6,710lbs 10L TRICON 1 413.3 ft3 6,650 lbs 10M TRICON 1 413.3 ft3 4,440 lbs 10N TRICON 1 413.3 ft3 5,050 lbs 10P TRICON 1 413.3 ft3 4,270 lbs TOTAL 15 7,066.20 ft3 82,720 lbs

Site Preparation and Maintenance Subsystem

Number of Sites: N/A Area: N/A

Capacity: N/A

Power Requirements: 120VAC, 60 Hz Potable Water Usage: N/A

Graywater Produced: N/A Fuel Requirements: N/A

Table 10. Site Preparation and Maintenance Subsystem Shipping Configuration. Container/

Item Type Quantity Cube (each) Weight (each)

11A TRICON 1 413.3-ft3 7,440-lbs 11B* TRICON 1 413.3-ft3 7,410-lbs 11C* TRICON 1 413.3-ft3 8,950-lbs

TOTAL 3 1,239.9 15,730-lbs

TM 10-5419-206-13 0019 00

Administration Subsystem

Number of Sites: 1 Area: 20,000-ft2/site

Capacity: Approximately 4,480 square feet of tent space in 7 TEMPER for various functions Power Requirements: 208VAC/3 phase/60 Hz, 12kW/TEMPER

Potable Water Usage: N/A Graywater Produced: N/A Blackwater Produced: N/A Fuel Requirements: None

Fuel Requirements for MSCW Configuration: ASH Heater (7units/0.5Gal/hr/24 Hours) = 84 Gallon/day

Morale, Welfare and Recreation (MWR) Subsystem

Number of Sites: 1 Area: 10,000-ft 2/site

Capacity: Approximately 2,000 square feet of tent space in 3 TEMPER for various functions Power Requirements: 208VAC/3 phase/60 Hz, 12kW/TEMPER

Potable Water Usage: N/A Graywater Produced: N/A Blackwater Produced: N/A Fuel Requirements: None

Fuel Requirements for MSCW configuration: ASH Heater (3units/0.5Gal/hr/24 Hours) = 36 Gallon/day

Table 11. Administration/MWR Subsystems Shipping Configuration. Container/

Item Type Quantity Cube (each) Weight (each)

12F TRICON 3 413.3 ft3 7,310 lbs 12B TRICON 1 413.3 ft3 5,930 lbs 12C TRICON 5 413.3 ft3 5,330 lbs 12E TRICON 1 413.3 ft3 4,890 lbs 11D ISO 1 1,280.3 ft3 8,510 lbs 11G TRICON 1 413.3 ft3 4,360 lbs 11H TRICON 1 413.3 ft3 9,740 lbs 12A TRICON 2 413.3 ft3 6,760 lbs TOTAL 15 7,066.50 ft3 88,770 lbs

TM 10-5419-206-13 0019 00

Floodlight Subsystem

Number of Sites: As required Area: 50-ft2/site

Capacity: 1000-Watt (Two 500-Watt Light Heads), or 2000-Watt (Four 500-Watt Light Heads) Power Requirements: 120VAC, 60 Hz, 8.34Amp

Potable Water Usage: N/A Graywater Produced: N/A Fuel Requirements: N/A

Additional Fuel Requirements for MSCW: N/A

Table 12. Floodlight Subsystem Shipping Configuration.

Container/ Item Type Floodlight Quantity Cube (each) Weight (each)

04C-1 1000W 2000W 1 1 See Note See Note 12C-3 1000W 2000W 1 See Note See Note 12C-2 1000W 2000W 1 See Note See Note 12C-5 1000W 2000W 1 See Note See Note 12C-4 1000W 2000W 1 See Note See Note 12C-1 1000W 2000W 1 See Note See Note 01B-14 1000W 2000W 1 1 See Note See Note 01B-13 1000W 2000W 1 1 See Note See Note 01B-15 1000W 2000W 1 1 See Note See Note 03B-1 1000W 2000W 1 1 See Note See Note 01B-4 1000W 2000W 1 1 See Note See Note 01B-3 1000W 2000W 1 1 See Note See Note 01B-6 1000W 2000W 1 1 See Note See Note 01B-5 1000W 2000W 1 1 See Note See Note 01B-1 1000W 2000W 1 1 See Note See Note 01B-2 1000W 2000W 1 1 See Note See Note 01B-11 1000W 2000W 1 1 See Note See Note 01B-10 1000W 2000W 1 1 See Note See Note 01B-12 1000W 2000W 1 1 See Note See Note 01B-7 1000W 2000W 1 1 See Note See Note 01B-9 1000W 2000W 1 1 See Note See Note 01B-8 1000W 2000W 1 1 See Note See Note 10E-2 1000W 2000W 1 1 See Note See Note 10E-1 1000W 2000W 1 1 See Note See Note 11D-1 1000W 2000W 3 2 See Note See Note 03B-2 1000W 2000W 1 1 See Note See Note

TOTAL 1000W 2000W 28 22 See Note See Note

Note: The cube and weight of each packed floodlight are included in the respective container data

Modification System (Power Generation)

Number of Sites: 9 Area: 1,300-ft2/site

Capacity: 208VAC/3 phase/60 Hz, 120kW/site Power Requirements: N/A

Potable Water Usage: N/A Graywater Produced: N/A Blackwater Produced: N/A

TM 10-5419-206-13 0019 00

Table 13. Modification System (Power Generation) Shipping Configuration. Container/

Item Type Quantity Cube (each) Weight (each)

21A TRICON 1 413.3 ft3 8,880 lbs 21B TRICON 1 413.3 ft3 7,812 lbs 60 kW TQG Skid 24 130 ft3 4,240 lbs

TOTAL 26 3,946.6 ft3 118,452 lbs

Modification System (Prime Power)

Number of Sites: 1 Generating Site, up to nine transformer sites Area: 8,400-ft2/generating site, 400-ft2/each transformer site Capacity: Four 750kVA Trailer/Generators

Power Requirements: N/A Potable Water Usage: N/A Graywater Produced: N/A Blackwater Produced: N/A

Fuel Requirements: 3,000 - 4,500 Gallon/day (depending on utilization)

Table 14. Modification System (Prime Power) Shipping Configuration. Container/

Item Type Quantity Cube (each) Weight (each)

31A TRICON 9 413.3 ft3 5,268 lbs 31C TRICON 1 413.3 ft3 5,754 lbs 32A TRICON 1 413.3 ft3 7,575 lbs 32B TRICON 1 413.3 ft3 10,018 lbs

TOTAL 12 4,959.60 ft3 28,607 lbs

Modification System Cold Weather

Number of Sites: N/A

Area: Approximately 238,053-ft2

Capacity: Augmentation for module serving 550 soldiers, 110 Support personnel Power Requirements: 814.5kW

Potable Water Usage: 21,125 Gallon/day Graywater Produced: 17,575 Gallon/day Blackwater Produced: 3,780 Gallon/day Fuel Requirements: 1,045 Gallon/day

Table 15. Modification System Cold Weather Shipping Configuration. Container/

Item Type Quantity Cube (each) Weight (each)

41A TRICON 17 413.3 ft3 4,660 lbs 42A TRICON 1 413.3 ft3 6,700 lbs 42B TRICON 1 413.3 ft3 7,740 lbs 42C TRICON 1 413.3 ft3 7,620 lbs 43A Modified TRICON 3 413.3 ft3 6,860 lbs 44A TRICON 1 413.3ft3 7,146 lbs 45A Modified TRICON 1 413.3 ft3 6,860 lbs

TOTAL 25 10,332.50 ft3 135,866 lbs