17. Data Input and Output
17.3 External Data Output
Preparations:
- Connect the external data medium (FE, ME or other peripheral unit, e.g. personal computer with HEIDENHAIN data transfer software) to the TNC.
- Prepare the external data medium for data transfer:
Press STOP , TNC and at the ME Press STOP at the FE.
- Select the operating mode, the baud rate and the interface assignment at the TNC (see section 16.1).
SERVICE MANUAL TNC 415B/425
Page 100 Issue: 20.08.95
17.3.1 Output of Files with the Extensions .H, .I, .T, .D, .P, .A, .PNT
Press Key Function
EXT
Operating mode PROGRAMMING/EDITING Activate data transfer menu
The different file types are distinguished by the file name and the extension.
In the TNC there are the following six different file types that can be selected via soft key:
- HEIDENHAIN dialogue programs <file name> .H
- ISO programs <file name > .I
- Tool tables <file name > .T 1)
- Datum tables <file name > .D
- Pallet tables <file name > .P
- Text files (ASCII) <file name > .A
- Point files <file name > .PNT
FE 1 interface mode
otherwise:
Soft keys to display all file types
Select file type
Soft key to confirm desired file type
Call external directory
Select file by pressing arrow keys
Start data transfer2)
Output further files
Soft key to exit data transfer
TNC in operating mode PROGRAMMING/EDITING
1) The file TOOL.T (active tool table) must be read out in another operating mode (see section 17.3.2) 2) see section 17.2
SERVICE MANUAL TNC 415B/425
Page 101 Issue: 20.08.95
17.3.2 Output of TOOL.T File (Active Tool Table) and of POCKET-TABLE
Press Key Function
EXT
EXT
TNC in MANUAL operating mode
Call tool table
Activate data transfer menu
Read out tool table
The active tool table is output to the external data medium;
filename: TOOL.T
Call pocket table
Activate data transfer menu
Read out pocket table
The POCKET TABLE is output to the external data medium;
filename: TOOL_P.R
Exit subprogram
SERVICE MANUAL TNC 415B/425
Page 102 Issue: 20.08.95
17.3.3 Output of the Machine Parameter List <NAME>.MP
NOTE:
The TNC only displays the external directory in the FE1 mode.
Press Key Function
MOD
9 5 1 4 8
ENTMOD
EXT
TNC in operating mode PROGRAMMING AND EDITING
Prepare TNC for entry of code number
Enter code number and confirm with ENT
Here an interface can be allocated to the MP editor
Activate data transfer menu
There may be several files with the extension .MP in the TNC. The active machine parameter list is distinguished by the STATUS M.
END
Soft key for data transfer
Exit data transfer menu
TNC in operating mode PROGRAMMING AND EDITING
SERVICE MANUAL TNC 415B/425
Page 103 Issue: 20.08.95
17.3.4 Output of the Compensation Value List for Multipoint Axis Error Compensation <NAME>.KOR
NOTE:
The TNC only displays the external directory in the FE1 mode.
Until NC software 259 93x.07 and 259 94x.07 the compensation values and the axis relations were filed in one table (file with extension .KOR). This file is stored in the RAM of the TNC and can be read out.
Press Key Function
MOD
1 0 5 2 9 6
ENTEXT
END
TNC in operating mode PROGRAMMING AND EDITING
Prepare TNC for entry of code number
Enter code number and confirm with ENT
Activate data transfer menu
Press soft key
The file <NAME>.KOR is stored on the external data medium as <NAME>.S
Exit data transfer menu
TNC in operating mode PROGRAMMING AND EDITING
SERVICE MANUAL TNC 415B/425
Page 104 Issue: 20.08.95
NOTE:
The TNC only displays the external directory in the FE1 mode.
As of NC software 259 93x.08 and 259 94x.08 the compensation values and axis relations can be stored as files with the extensions .COM and .CMA.
Press Key Function
MOD
8 0 7 6 6 7
ENTEXT
MOD
TNC in operating mode PROGRAMMING AND EDITING
Prepare TNC for entry of code number
Enter code number and confirm with ENT
Activate data transfer menu
Here the PLC editor can be assigned to an interface
Press arrow key to select the TNC directory
Soft key and arrow key on VDU
List <NAME>.COM
Read out <NAME>.COM
Soft key and arrow key on VDU
List <NAME>.CMA
Read out NAME>.CMA
*
If no .CMA file is defined and multipoint axis error compensation selected via MP730, the compensation value tables of the code number 105296 are valid.SERVICE MANUAL TNC 415B/425
Page 105 Issue: 20.08.95
17.3.5 PLC File Management
Press Key Function
MOD
8 0 7 6 6 7
ENTPGM NAME
TNC in operating mode PROGRAMMING AND EDITING
Prepare TNC for entry of code number
Enter code number and confirm with ENT
Call file manager
Split screen
Press soft key
Press soft key
The PLC is subdivided into two internal drives.
Drive TNC: PLC files in RAM 1)
Drive TNC/EPROM: PLC files in PLC EPROM 1)
The following files may be stored:
PLC programs
Error messages 1. language Error messages English
Dialogues 1. language
Dialogues English
ASCII files Help texts
Data for axis error compensation Data for axis error compensation
.PLC .ER1 .ERE .DI1 .DIE .A .HLP .COM .CMA
For each half of the screen the required "drive" can be selected by soft key.
1) Between the PLC RAM and the PLC EPROM similar functions are possible as between the RAM and external data medium.
SERVICE MANUAL TNC 415B/425
Page 106 Issue: 20.08.95
Selecting the Drives
Press Key Function
or
or
Select the window to be modified
Switch soft key row
Press soft key
SERVICE MANUAL TNC 415B/425
Page 107 Issue: 20.08.95
Press Key Function
or
Assign the "drive" by pressing a soft key
Press soft key
Switch soft key row back
SERVICE MANUAL TNC 415B/425
Page 108 Issue: 20.08.95
17.3.6 Output of Files from PLC Memory
NOTE:
The TNC only displays the external directory in the FE1 mode.
Overview of the Files PLC programs
Error messages 1. language Error messages English
Dialogues 1. language
Dialogues English ASCII files
Help texts
Files for axis error compensation Files for axis error compensation
.PLC .ER1 1) .ERE 1) .DI1 1) .DIE 1) .A 1) .HLP .COM 2) .CMA 2)
1) Note:
The error messages, dialogues and ASCII files are output as ASCII files with the extension .A.
Therefore, the files to be output must have different filenames so that they will not be overwritten on the external data medium.
(to rename a files, press the soft key .) Note down filename and the extension!
After having downloaded the files, the extension .A must be reconverted to the original extension
by pressing the soft key .
2) see section 17.3.4
*
There may be several files with the same extension in RAM.Note down status information (see section 17.2).
SERVICE MANUAL TNC 415B/425
Page 109 Issue: 20.08.95
Press Key Function
MOD
8 0 7 6 6 7
ENTEXT
in interface mode FE 1
otherwise:
END
TNC in operating mode PROGRAMMING AND EDITING
Prepare TNC for entry of code number
Enter code number and confirm with ENT
Activate data transfer menu
Soft keys to display all file types
List desired file type
Select desired file with arrow keys (if necessary)
Rename file with soft key (if necessary)
Start data transfer 1)
Output further file, if desired
Soft key to exit the data transfer menu
TNC in operating mode PROGRAMMING AND EDITING
1) see section 17.1
SERVICE MANUAL TNC 415B/425
Page 110 Issue: 20.08.95