UEH Exception traces print lh all te log read|grep -i "UEH_*"
#################################################################################
Check out this command : lgvsm -s XXXXXXXX...with XXXXXXXX start date in the format of 20110215..for Feb 15th 2011 3:59:48 PM: Sivanesan Renganaickam: run it frm Node B or RNC depending the Node u wanna check
#################################################################################
Check T1 errors:
pget t1
to check the aal2 config on the RBS CHTWWVU4077> stv
To get the vc/atmport
CUDNWVAARNC001> get b4077
On the RNc to check AAL2
CUDNWVAARNC001> lget AtmPort=ES5-2-1VplTp=vp3 VpcTp=1 traff
######## CHECK for OPERATINAL HISTORY on NODEB ORNEK> lgo
100120-13:08:35 10.85.229.199 7.1p RBS_NODE_MODEL_L_10_9 stopfile=/tmp/528 Startdate=19661031.171320 Enddate=20100121.110836
Get /c/logfiles/audit_trail/CORBA_AUDITTRAIL_LOG.xml /var/opt/ericsson/amos/moshell_logfiles/scol/logs_moshell/tempfiles/20100120-111323_144/audit_trailLog528.xml.tmp ... OK
======================================================================================================
Timestamp (UTC) Description
FAULT DETECTION
======================================================================================================
2010-01-19 09:30:42 MO-A SET NodeBFunction=1Iub=ORNEKIubDataStreams=1 maxHsRate 120
2010-01-19 09:30:57 MO-A ACT SwManagement=1ConfigurationVersion=1 create aftermaxhsrate120|aftermaxhsrate120|5|gboz|none 2010-01-19 09:30:58 MO-A ACT SwManagement=1ConfigurationVersion=1 setStartable aftermaxhsrate120
2010-01-19 10:31:06 MO-A ACT SwManagement=1ConfigurationVersion=1 create before_restart|before_restart|5|scol|none 2010-01-19 10:31:07 MO-A ACT SwManagement=1ConfigurationVersion=1 setStartable before_restart
2010-01-19 10:31:41 MO-A ACT ManagedElement=1 manualRestart 2|0|2 2010-01-19 10:36:44 MO-A SET ManagedElement=1 userLabel ORNEK 2010-01-19 15:14:35 MO-A SET Equipment=1SectorAntenna=1AuxPlugInUnit=RRUW-1 administrativeState 0 2010-01-19 15:15:21 MO-A ACT Equipment=1SectorAntenna=1AuxPlugInUnit=RRUW-1 restartAuxUnit 2010-01-19 15:15:57 MO-A SET Equipment=1SectorAntenna=1AuxPlugInUnit=RRUW-1 administrativeState 1 2010-01-19 17:22:48 MO-A SET ManagedElement=1 userLabel ORNEK 2010-01-19 17:25:23 MO-A ACT Equipment=1Subrack=1 Slot=1 PlugInUnit=1 manualRestart 2|0|ss 2010-01-19 17:29:48 MO-A SET ManagedElement=1 userLabel ORNEK
######## CHECK for ALARM HISTORY on NODEB ORNEK> lga
100120-13:07:21 10.85.229.199 7.1p RBS_NODE_MODEL_L_10_9 stopfile=/tmp/528 Startdate=19661031.171320 Enddate=20100121.110722
...Get /c/logfiles/alarm_event/ALARM_LOG.xml /var/opt/ericsson/amos/moshell_logfiles/scol/logs_moshell/tempfiles/20100120-111323_144/alarmLog528.xml ... OK
====================================================================================================================
######## CHECK for RESTARTS on NODEB ORNEK> bo
100108-12:34:30 10.85.229.13 7.1p RBS_NODE_MODEL_L_10_9 stopfile=/tmp/7580
================================================================================================================================
00 BoardType SwAllocation
================================================================================================================================
01 CBU1 Main_CBU
ORNEK> lhsh 000800 llog-> Check for RAX board Restart ORNEK> lhsh 001000 llog-> Check for TX board Restart ....
######## CHECK Error/Fault/Failure on NODEB
ORNEK> ter | grep -i error ORNEK> ter | grep -i Fault ORNEK> ter | grep -i Failure Use PRIMUS for analize
http://e-support.ericsson.se/reader_iview/ui/eserver.asp
######## CHECK for BOARD FAULTY on NODEB ORNEK> bo
100108-12:34:30 10.85.229.13 7.1p RBS_NODE_MODEL_L_10_9 stopfile=/tmp/7580
================================================================================================================================
ORNEK> lhsh 000800 te log read
ORNEK> lhsh 000600 te log read
[2009-11-02 13:32:14.232] ecEfhFhEncC[28] ../src/EcEfhRuGroupFhEncC.cpp:2088 INFO:ABN:Equipment fault: /RU:0:13:8:2/ bbClockFaultInd faultType: RBS_FAULT_TYPE_BFN_PHASE_ERROR faultTypeId: 511 faultRecoveryAction: RBS_RECOVERY_ACTION_NO_SUGGESTED_ACTION Additional info: clockSignalId: 2 [2009-11-02 13:34:23.256] ecEfhFhEncC[26] ../src/EcEfhRuGroupFhEncC.cpp:2088 INFO:ABN:Equipment fault: /RU:0:13:0:2/ bbClockFaultInd faultType: RBS_FAULT_TYPE_BFN_PHASE_ERROR faultTypeId: 511 faultRecoveryAction: RBS_RECOVERY_ACTION_NO_SUGGESTED_ACTION Additional info: clockSignalId: 2
Use PRIMUS for analize
http://e-support.ericsson.se/reader_iview/ui/eserver.asp
Check out this command : lgvsm -s XXXXXXXX...with XXXXXXXX start date in the format of 20110215..for Feb 15th 2011
Get /c/logfiles/audit_trail/CORBA_AUDITTRAIL_LOG.xml /var/opt/ericsson/amos/moshell_logfiles/scol/logs_moshell/tempfiles/20100120-111323_144/audit_trailLog528.xml.tmp ... OK
======================================================================================================
======================================================================================================
...Get /c/logfiles/alarm_event/ALARM_LOG.xml /var/opt/ericsson/amos/moshell_logfiles/scol/logs_moshell/tempfiles/20100120-111323_144/alarmLog528.xml ... OK
====================================================================================================================
====================================================================================================================
================================================================================================================================
================================================================================================================================
================================================================================================================================
================================================================================================================================
################### ###################
copy to follow for each site Window2
/opt/ericsson/amos/moshell/monitor6054 10.174.0.196 33080 > "/home/scol/serhat/Rssi/20100115-ORNEK.log"
get file to local Computer open with wordpad and save
Window1
MTW02R1> lh mod32 te e all RNC_EXCEPTION MTW02R1> mon+ mod32
. . .
$moncommand = /opt/ericsson/amos/moshell/monitor6054 10.174.0.196 33080-> copy it and go to 2nd window Window 2
scol@selaps1> /opt/ericsson/amos/moshell/monitor6054 10.174.0.196 33080 > /home/scol/serhat/Traces/ORNEK.log-> Record it your selected folder .
wait how much you want .
. Ctrl+C Window 1
MTW02R1> lh Mod32 te d all RNC_EXCEPTION MTW02R1> mon- mod32
. . .
$ lhsh 001000 tm -disconnect
All monitored boards are disconnected and Target Monitor has shut down.
Go to your folder and download it your local computer
######## INSTAL DECODER for TRACE ANALIZE
1-) Download latest decoder from http://utran01.au.ao.ericsson.se/moshell/content.php?content.7 2-) Copy it your local directory in OSS
3-) un zip it in your local diroctory
scol@selcuk> unzip decoder3.1h.zip Archive: decoder3.1h.zip
inflating: decoder.tgz inflating: decoder_install scol@selcuk> ls
decoder.tgzdecoder3.1h.zip decoder_install 4-) scol@selcuk> ./decoder_install
#########################################
Installation of Field Decoder 3.1h
#########################################
Please enter the directory where decoder should be installed (auto-completion using <TAB>): /home/scol/decoder/-> Install it in your selected directory This directory doesn't exist. Creating it...
Path to perl: /usr/bin/perl. OK? [y/n] y
Starting Installation....
Unzipping decoder.tgz....
Untaring decoder.tar....
x decoder 0 bytes 0 tape blocks x decoder/SpBag 0 bytes 0 tape blocks x decoder/SpBag/Decode.pm 9015 bytes 18 tape blocks x decoder/SpBag/Map.pm 15469 bytes 31 tape blocks .
You can now run decoder from the directory /home/scol/decoder.
5-) scol@selcuk> chmod -R 700 /home/scol/decoder/
6-)Check Decoder files
*.pl files are specific decoders using for analize
scol@selcuk> cd decoder/
scol@selcuk> ls
GPEH_tab2flow.pl concat_segmented_rlib_traces.pl PmEventSpecification_AU3.xml decoder.pl
PmEventSpecification_BA4.xml decoder_ss7 PmEventSpecification_BC5.xml flow.pl PmEventSpecification_BJ5.xml flow_ss7 PmEventSpecification_BN1.xml flowfilter.pl PmEventSpecification_BN3.xml flowfox.pl
PmEventSpecification_BU5.xml historyDecoder.pl PmEventSpecification_RBS.xml lib
README msflow.pl
RELEASE_HISTORY_DECODER.TXT pdu_map.txt SpBag postprocess.pl
######## USE A DECODER for ANALIZE
scol@selcuk> cat /home/scol/serhat/Traces/ORNEK | /home/scol/decoder/teSummary.pl > /home/scol/serhat/Traces/ORNEK_DEC --->---analize ORNEK.log--->---use teSummary.pl--->---write slected
check ORNEK_DEC file in your folder
######## OTHER TRACES on RNC (CAN RUN SAME WAY)
* All of them can be run same way (Did not try all traces)
* teSummary.pl file can be use all traces
lh mod te e all RNC_EXCEPTION lh mod te e all UEH_EXCEPTION lh mod te e all DRH_EXCEPTION lh mod te e all PM_OBS_EXCEPTION lh mod te e trace3 IU_IF
lh mod te e all ADMISSION_REJECT_CELL lh mod te e trace4 UE_GENERAL
lh dc te e all SP_EXCEPTION lh cc te e all SP_EXCEPTION lh dc te e all SP_CONFIG_REJ lh cc te e all SP_CONFIG_REJ lh dc te e all DISCARD_UE lh dc te e all RETRANSM_UE
lh dc te e trace1 HANDOVER_EVAL_UE
/opt/ericsson/amos/moshell/monitor6054 10.174.0.196 33080 > "/home/scol/serhat/Rssi/20100115-ORNEK.log"
-> Get Iub for selecter Site (RncModule=32) -> Enable trace
-> Start monitoring
-> copy it and go to 2nd window
-> than go to 1st Window
-> Disable trace
-> Stop monitoring
-> Install decoder
scol@selcuk> cat /home/scol/serhat/Traces/ORNEK | /home/scol/decoder/teSummary.pl > /home/scol/serhat/Traces/ORNEK_DEC --->---analize ORNEK.log--->---use teSummary.pl--->---write slected