• No results found

Signalling PP-Test and Signalling FP-Test

B- Field Modulation

Syntax:

Execute new measure- ment and signal result Only read result

READ[:SCALar]:BFIeld?

FETCh[:SCALar]:BFIeld? Return: <Value>, <Value> (Unit: Hz)

State: DCE Option: none Only query Note: The first value is the positive value, the second is the negative one; (N10)

1094.0006.60 C.15 E-5

Pass / Fail verdict for Frequency Drift

Syntax: CALCulate:LIMit:FREQuency:DRIFt:TOLerance:MATChing? Return: (MATC | NMAT | INV)

State: DCE Option: none Only query Note: It's only measured, if signalling mode is set to LOOPback and if data type in B-Field is set to Fig31 or BS55 (otherwise returns INValid) Returns the result of the last measurement (N10), (N12)

Frequency Drift

Syntax:

Execute new measure- ment and signal result Only read result

READ[:SCALar]:FREQuency:DRIFt?

FETCh[:SCALar]:FREQuency:DRIFt? Return: <Value> (Unit: Hz/s)

State: DCE Option: none Only query Note: It's only measured, if signalling mode is set to LOOPback and if data type in B-Field is set to Fig31 or BS55 (otherwise returns INValid) (N10)

The relations between the occuring frequency drift units are

slot

kHz

4

.

2

1

ms

kHz

1

s

Hz

10

6

=

=

. Frequency Drift (kHz/ms) Syntax: Execute new

measurement and signal result:

Only read result:

READ[:SCALar]:FREQuency:DRIFt:MS?

FETCh[:SCALar]:FREQuency:DRIFt:MS? Return: <value> (Unit: kHz/ms)

State: DCE Option: none Only query Note: Frequency drift is only measured if the signalling mode is set to LOOPback and if the data type is set to Fig31 or BS55 (otherwise returns INValid).

Frequency Drift (kHz/slot)

Syntax: Execute new

measurement and signal result:

Only read result:

READ[:SCALar]:FREQuency:DRIFt:SLOT?

FETCh[:SCALar]:FREQuency:DRIFt:SLOT? Return: <value> (Unit: kHz/slot)

State: DCE Option: none Only query Note: Frequency drift is only measured if the signalling mode is set to LOOPback and if the data type is set to Fig31 or BS55 (otherwise returns INValid).

Transmission of Z-field

Syntax: Execute new

measurement and signal result:

Only read result:

READ:XZField:MATChing?

FETCh:XZField:MATChing? Return: (MATC | NMAT | INV)

State: DCE Option: none Only query Note: The transmission of Z-field is only measured if the data type is set to PSRBS (otherwise returns INValid). (N10)

FM-Demodulated Signal

Syntax:

Execute new measure- ment and signal result Only read result

READ:ARRay:FREQuency:DEViation?

FETCh:ARRay:FREQuency:DEViation? Return: <Value> {, <Value>} (Unit: kHz)

1094.0006.60 C.17 E-5

9. Menu: Timing

Pass/Fail Verdict for Time Accuracy

Syntax: CALCulate:LIMit:TIME:ACCuracy:TOLerance:MATChing? Return: (MATC | NMAT | INV)

State: DCE Option: none Only query Note: Returns the result of the last measurement (N10), (N12)

Time Accuracy

Syntax:

Execute new measure- ment and signal result Only read result

READ[:SCALar]:TIME:ACCuracy?

FETCh[:SCALar]:TIME:ACCuracy? Return: <Value> (Unit: ppm) State: DCE Option: none Only query Note: (N10)

Pass / Fail Verdict for Jitter

Syntax: CALCulate:LIMit:JITTer:TOLerance:MATChing? Return: (MATC | NMAT | INV), (MATC | NMAT | INV)

State: DCE Option: none Only query Note: Returns the result of the last measurement, the first value is the positive value, the second is the negative one, (N10), (N12)

Jitter

Syntax:

Execute new measure- ment and signal result Only read result

READ[:SCALar]:JITTer?

FETCh[:SCALar]:JITTer? Return: <Value>, <Value> (Unit: sec)

State: DCE Option: none Only query Note: The first value is the positive value, the second is the negative one, (N10)

Pass / Fail Verdict for Packet Transmission Accuracy of a PP

Syntax: CALCulate:LIMit:PACKet:DELay:TOLerance:MATChing? Return: (MATC | NMAT | INV), (MATC | NMAT | INV)

State: DCE (PP test only)

Option: none Only query Note: Returns the result of the last measurement, the first value is the result for the minimum, the second is the result for the maximum, (N10), (N12)

Packet Transmission Accuracy of a PP

Syntax:

Execute new measure- ment and signal result Only read result

READ[:SCALar]:PACKet:DELay?

FETCh[:SCALar]:PACKet:DELay? Return: <Value>, <Value> (Unit: sec) State: DCE

(PP test only)

Option: none Only query Note: The first value is the minimum value, the second is the maximum one, (N10)

1094.0006.60 C.19 E-5

10.

Menu: Bit Error Rate

RF Level

Syntax: CONFigure:BER:RF:LEVel <numeric_value>

Value range: -100.0 dBm to -40.0 dBm (in steps of 0.1 dBm) Default: -73.0 dBm State: DCE Option: none With query

Pass / Fail Verdict for LongTerm BER and FER

Syntax: CALCulate:LIMit:BER:LTERM:TOLerance:MATChing? Return: (MATC | NMAT | INV), (MATC | NMAT | INV)

State: DCE Option: none Only query Note: Returns the result of the last measurement; the first value is the BER value, the second one the FER value; (N10), (N12)

LongTerm BER and FER

Syntax:

Execute new measure- ment and signal result Only read result

READ[:SCALar]:BER:LTERm?

FETCh[:SCALar]:BER:LTERm?

Return: <Value>, <Value> (Unit: BER %, FER %)

State: DCE Option: none Only query Note: The first value is the BER value, the second one the FER value, (N10)

Enable/disable BER Software Decoding

Syntax: CONFigure:BER:RF:SWDEcoding? Value range: ON,

OFF

Default: OFF

11.

Menu: Signalling PP-Test Configuration

Static System Info

Syntax: CONFigure:PP:PROTotype:SYSTem:INFO <string>

Value range: 12 digits in hex format Default: "000003FF0000" State: Set: IDLE, DPP

Query: ALL

Option: none With query

Fixed Part Capabilities

Syntax: CONFigure:PP:PROTotype:FP:CAPability <string>

Value range: 12 digits in hex format Default: "003041108008" State: Set: IDLE, DPP

Query: ALL

Option: none With query

Multiframe Number

Syntax: CONFigure:PP:PROTotype:MULTiframe <string>

Value range: 12 digits in hex format Default: "006F0F000000" State: Set: IDLE, DPP

Query: ALL

Option: none With query

Q Packet Multiplex Sequence

Syntax: CONFigure:PP:TABLe:QPACket:SEQuence <string>

Value range: 8 digits out of 0, 3, 6 Default: "03030303" State: Set: IDLE, DPP

Query: ALL

Option: none With query Note: The default value is different from the CMD60 default value which is "03060306"