• No results found

Fixed in version 28.1.6.0

In document AAS-28_1_11_0-RN (Page 38-45)

Item Description Bug ID

1. When cookie insert for persistency and Layer 7 string matching were configured in an HTTPS offloading service, and the traffic did not contain any matching cookie or string, a server was selected instead of

responding with HTTP error 503 (server unavailable). prod00162602 2. With a heavy load of HTTP "Connection: close" traffic

and connection management enabled, software panic sometimes occurred when several responses were

sent from the server for one request. prod00162148 3. When the port command was retransmitted, Active

FTP load balancing did not work properly. prod00162078 4. Under certain circumstances, unpredictable behavior

occurred with certificate management (such as loss of keys, unable to connect via SSH, the diff flash holds

the configuration after reboot, and so on). prod00161974 5. When a client HTTPS request did not match any of the

strings assigned to the real servers, after Alteon reset

no response was received and SSL terminated. prod00161818 6. When the GSLB network IP version was not manually

defined, the proximity GSLB worked incorrectly. prod00161647 7. The redundant capability of setting an SNMP service

with TCP protocol was removed. prod00161584

Item Description Bug ID 8. The configuration apply command generated incorrect

and irrelevant VRRP syslog messages. prod00161579 9. Transferring a large file using an HTTPS service took

much longer compared to an HTTP service, because a

small TCP window size was set. prod00161459

10. For virtual services configured with SSL offloading where the front-end and back-end ports are the same, the service back-end port on the backup device was

changed during configuration synchronization. prod00161446 11. Using VRRP with stateful failover configured, when the

backup device booted up after upgrading to version

28.1.5, the master device rebooted repeatedly. prod00161442 12. In version 28.1.5.0, when X-Forwarded-For was using

with dbind enabled, the sequence number on the

second get request to server was incorrect. prod00161266 13. In version 28.1.2.0, an image upgrade via HTTP

transport caused a panic. prod00161254

14. In BBI, a clear operation in SLB monitoring cleared the

session table instead of clearing SLB statistics prod00161019 15. In an HTTP persistency configuration, the path was

added to the cookie header even though it was not

configured in the pbind cookie insert configuration. prod00161011 16. The connection splicing statistic was not updated with

dbind forceproxy. prod00161007

17. Alteon panicked when "host:" string was not found in

the URI of a request. prod00160900

18. The RADIUS secret password was synced during

configuration sync. prod00160668

19. When all the real servers in a group and backup group were down, the virtual server information displayed the

backup group as disabled. prod00160637

20. On Alteon with SSL acceleration card, a very heavy

load can cause a switch panic prod00160610

21. The swkey (license information) command did not

display the installed default throughput license. prod00160459 22. A non-updated Geo database was used, causing Geo

IP resolution for a DNS query to be incorrect. prod00160397

Item Description Bug ID 23. In certain cases, out-of-order fragments traffic with

proxy IP configured caused the device to crash. prod00160348 24. After upgrading from version 28.0 to 28.1, an apply

failed due to a certificate synchronization error, even

though no certificate was configured. prod00160341 25. Active FTP load balancing did not work properly when

PORT command retransmission occurs. prod00160294 26. On a virtual service with both caching and compression

policies, when compression was set disabled, caching

also stopped working prod00160249

27. After USB recovery, redundant message appeared

before the login prompt prod00159887

28. On on Alteon 5224, STP and LACP packets that were received on ports without a VLAN tag configured were

dropped. prod00159860

29. In a vADC hot-standby configuration with Layer 4 switch port tracking enabled, resetting the master vADC caused the backup vADC to take over only until

the master vADC started again. prod00159834

30. session matched on redirect filter with Linklb and FTPA enabled where created with ageing 0 and got

disconnected quickly prod00159775

31. On 4408/4408-XL devices, throughput license information showed irrelevant value when default

throughput license was installed prod00159763 32. It was possible to set the default gateway address to a

virtual server and PIP. prod00159741

33. In a vADC, server responses with the destination MAC of a different vADC were not processed and were then

dropped. prod00159723

34. During image download on VX, LACP trunks where blocked for about 2 minutes causing network traffic

instability prod00159550

35. When persistent entry exists but corresponding real server was down or disabled, Alteon answered with HTTP Error 503 (Service unavailable) instead of

selecting new server prod00159531

Item Description Bug ID 36. When TCP based health checks (i.e HTTP, FTP) were

configured for UDP based services, TCP port health

check was performed instead of ICMP prod00159427 37. The ADC-VX MIB-II did not support 64-bit counters.

ADC-VX interfaces were incorrectly displayed as

10/100 instead of Gigabit or 10Gigabit. prod00159381 38. In curtain cases, Direct Server Return (nonat enabled)

caused switch panic prod00159357

39. SSL session failed after configuration apply due to

certificate synchronization prod00159323

40. BBI showed incorrect user login information when login-in from the same host with different users which

has the same COS prod00159298

41. PIP statistics update of VLAN based PIP, caused the

vADC to crash prod00159297

42. In an ADC-VX environment, XL devices were not

indicated as XL in CLI displays. prod00159257 43. Switch panicked when real comes back up causing the

backup real servers to become disabled prod00158835 44. Navigation option between the Virtual Servers BBI

pages was missing prod00158669

45. After disabling connection management functionality in

a service, a persistency problem occurred. prod00158650 46. Active FTP load balancing did not work properly

because of the wrong adjustment to the sequence

number prod00158622

47. When static route is not covered by localnet, default gateway will be used. Removed confusing warning

message appeared in such cases prod00158609 48. Update of server certificate name via BBI was not

possible prod00158590

49. Active FTP load balancing did not work properly due to

wrong adjustment of the sequence number prod00158572 50. Certain SNMP traps caused the device to crash prod00158525 51. Virtual server current session statistics, showed

strange value via BBI prod00158470

Item Description Bug ID 52. It was not possible to disable SSL offloading for a VIP

via BBI prod00158456

53. Responses from Virtual Server were linked to the same port of the trunk and therefore limit the

throughput to 1 Gbps. This happened since the trunk load balancing algorithm used only source IP instead of

source IP + destination IP prod00158403

54. Enable "IP TOS matching" on a filter through BBI also

enabled the "IP Option Matching" prod00158281 55. Empty trunk name appeared in the configuration dump

caused failure in restoring configuration prod00158111 56. On a 5412 platform, TACACS+ authentication caused

the device to crash.

prod00157976

57. In BBI, the Alteon-VX dashboard did not work.

Also, HTTP request over management port with an empty Host header caused the device to crash

prod00157799

58. VRRP flap occurred when uploading tech support dump or viewing real servers information on backup

vADC1. prod00157771

59. On 4408 and 4416 devices, the putdumps maintenance command failed.

prod00157731

60. On a 5412 platform, the device crashed with a link load balancing configuration with fragmented traffic.

prod00157666

61. In CLI and BBI displays, an Alteon 4408 device with an SSL card was not identified as 4408XL.

prod00157617

62. Heavy load caused Alteon to sent irrelevant trap

(OCSP related) prod00157309

63. When "regex" or "none" where incorrectly defined as the HTTP modification element, a panic occurred.

prod00157033

64. The default compression license for 5224XL was changed from 500 Mbps to 1Gbps.

prod00157011

65. On device startup, a duplicate SNMP temperature trap was sent where one of the messages had incorrect information.

prod00156974

66. When only one power supply was installed in a dual power supply device, an SNMP trap reporting this problem was not generated.

prod00156903

Item Description Bug ID 67. After upgrading to version 28.1.5, all vADCs went down

and their image statuses were displayed as Incompatible.

prod00156868

68. In SNMP traps sent on data port, the wrong agent-address was included, and the incorrect OID was reported in slbCurCfgRealServerOid.0

prod00156813

69. In a vADC environment, when the syslog default port was configured on a management port, the source IP address of the syslog packets was the ADC-VX management IP instead of the vADC management IP.

prod00156720

70. Persistency break sometime occurred when a cookie arrived to an SP which did not contain the persistent

entry of that cookie prod00156706

71. During configuration sync, port number was replaced

with port allies causing a problem in VRRP failover prod00156661 72. When all primary servers were configured as disabled,

the backup servers moved from the blocked to the up state when one of the backup servers was disabled

operationally. prod00156636

73. In certain cases, active FTP LB with client NAT did not work.

prod00156619

74. When VLAN based PIP was configured, no PIP statistics were generated.

prod00156548

75. An Apply generated incorrect and irrelevant VRRP syslog messages.

prod00156531

76. In a vADC, a user with CoS set to user was unable to enable or disable the real servers that were assigned to him, while the l3oper user was able to do enable or

disable real servers that were not assigned to him. prod00156384 77. After upgrading from version 28.0 to 28.1, an apply

failed when VRRP hot-standby was configured.

prod00156344

78. The string "v4" was mistakenly added to the SMTP hostname in the configuration dump.

prod00156070

79. False fan traps were sent on a vADC. prod00155948 80. When a vADC was down, BPDUs in corresponding

VLAN were not blocked.

prod00155824

81. After upgrading from version 27.0.x to 28.1.2.x, An prod00155794

Item Description Bug ID apply failed when X-ForwardedFfor configured for a

service.

82. Throughput license is up to 16 Gbps for the 5224 and 5224XLplatforms. This was incorrectly stated in previous release notes.

prod00155691

83. After upgrade from 27.0.2.0 to 28.1.2.0 with dbind disabled and X-Forward-For enabled, after changing dbind to enabled on a service, an error message was issued, and the device crashed.

prod00155689

84. A vADC panic caused the SYS LED to turn red. Only rebooting the device turned the LED back to green.

prod00154297

85. During the upgrade process of a cluster, after one device was upgraded from version 28.0. to 28.1, the cluster changed to the VRRP Master-Master state.

prod00153379

86. A link UP was reported on port with the Copper SFP module inserted, even though the cable was not connected.

prod00152580

87. vADC throughput statistic was shown in MB rather than

Mbps prod00152104

88. When attempting to reset a vADC or device, a

message is issued that there is an unapplied/unsaved configuration even though the configuration was applied and saved.

prod00151807

89. An NTP server IP address could not be deleted (set to default 0.0.0.0 value).

prod00151632

90. After SSH login, the SSH management session sometimes hangs.

prod00151316

91. In dbind forceproxy service, If the client delayed in sending the FIN,ACK to Alteon as a response to FIN, the session entry was aged in slow aging rather than

fast aging prod00151145

92. After applying system configuration changes, incorrect SLB log messages were issued.

prod00151057

93. When an IPv4 VRRP group was enabled, it was possible to define an IPv6 VSR. This caused the IPv6 VSR to be unreachable.

prod00150485

94. When connection management was enabled and prod00141402

Item Description Bug ID egress PIP was configured (as recommended), Alteon

still required the ingress PIP address to be configured.

In document AAS-28_1_11_0-RN (Page 38-45)

Related documents