20 069-581 Diverter Valve Installation 1 RSP
21 069-581 Diverter Valve Assembly 1 RSP
22 071-001 Heavy Duty Battery 1 RSP
23 071-1240 Teleradio Control System (Transmitter and
Receiver) 1 RSP
24 071-1242 Pressure Transmitter (Transducer) 1 RSP
25 071-1382 Murphy Control Panel 1 RSP
ITEM FLOWPLANT PART
NO DESCRIPTION QTY CODE
33 071-1494 25 Amp Fues (Blade) 1 RSP
34 071-367 E-Stop Twist to Release 1 RSP
35 071-664 40 Amp Fues (Blade) 1 RSP
36 071-886 Float Valve 1 RSP
37 A030784 Hydraulic Cylinder 1 RSP
38 N05-105 Line Strainer 1 1/4" 1 RSP
39 N05-108 Line Strainer O'ring/Seal 1 RSP
40 N06-021 Line Strainer Element 1 RSP
SSP = SERVICE SCHEDULE PARTS – PARTS THAT ENGINEERS SHOULD HOLD TO USE WITHIN SERVICE
RSP = RECOMMENDED SPARE PARTS – PARTS THAT ENGINEERS SHOULD HOLD TO COVER LIKELY PARTS TO FAIL OR CAUSE BREAKDOWNS
10) TELERADIO PAIRING
Erasing a Transmitter from the Receiver
This procedure requires the receiver to be erased to have power and the operator has to be in range of that receiver.
Pull out the e-stop on the remote.
1. Press and hold button 6 (bottom right start button).
2. While holding button 6, push in the e-stop.
3. Release button 6. Remote is now in the menu. Pressing button 1 will lower the cursor, pressing button 2 will raise the cursor.
4. Press and release button 1 until the cursor is on [Erase].
5. Press and release button 5. Pressing button 1 will lower the cursor, pressing button 2 will raise the cursor.
6. Once the cursor is on the slot of the receiver that you want to erase, press and release button 5. Screen will [NO]
7. Press and release button 1. Screen will display [YES].
8. Press and release button 5. Screen will display [Erasing…]. If erasing failed, screen displays [Failed]; if erasing is successful, screen displays [Ok].
Register a New Transmitter in the Receiver
Release the e-stop of the new remote. If no receivers are in memory of the transmitter, screen will display [NO RECEIVERS Press MENU + STOP].
1. Press and hold button 6.
2. While holding button 6, push in the e-stop. Remote is now in the menu. Pressing button 1 will lower the cursor, pressing button 2 will raise the cursor.
3. Press and release button 1 until the cursor is on [Register].
4. Press and release button 5 to enter the register submenu. Screen will display all the slots that are in use (with a serial number of the receiver) and/or available (with empty). Pressing button 1 will lower the cursor, pressing button 2 will raise the cursor.
5. Once the cursor is on an [Empty] slot, press and release button 9. Screen will [NO]
6. Press and release button 1. Screen will display [YES].
7. Press and release button 6. Screen will display [Registering…]. Transmitter is now in register mode.
8. Inside the receiver, press and release the function button (see image below for reference).
Next step must be completed within 4 seconds.
9. Inside the receiver, press and release the select button. All red relay LEDs will light up red, indicating the receiver is in register mode. Receiver will remain in register mode for 1 minute or until it acknowledges a transmitter in register mode.
10. Once all red relay LEDs begin to flash, confirm the pairing by pressing and releasing the select button inside the receiver. Screen on the transmitter will display [Successful] and shut off.
Erasing all Receivers from the Transmitter (Reset)
This procedure will erase all receivers from the transmitter. This procedure should only be completed if the receiver(s) in memory are lost or destroyed.
While the e-stop is in, press and hold button 1+2.
1. While holding buttons 1+2, release the e-stop. Screen will display [KEEP BUTTONS PRESSED]. Continue to hold buttons for about 5 seconds. Screen will display [Release Buttons].
2. Release the buttons. Screen displays [Erase All RX push blinking buttons to confirm reset]
and LEDs 1-4 blinking.
3. Press and release the buttons in the following order. 1-2-3-4. If a button is not pressed after 4 seconds between each press, the transmitter will start up and this procedure has to be restarted. [All receivers erased] will be displayed if successful.
Replace
Make note of the serial number of the transmitter to be replaced, this serial number must be entered in the new transmitter. The new transmitter must be within range of the receiver and receiver must have power during this procedure. Please note, the slot on the new transmitter where the receiver is saved on the old transmitter must be free for the replace to be successful.
1. Release the e-stop of the new remote. If no receivers are in memory of the transmitter, screen will display [NO RECEIVERS Press MENU + STOP].
2. Press and hold button 6.
3. While holding button 6, push in the e-stop.
4. Release button 6. Remote is now in the menu. Pressing button 1 will lower the cursor, pressing button 2 will raise the cursor.
5. Press and release button 1 until the cursor is on [Replace].
6. Press and release button 5 to enter the replace submenu. Screen will display Replace and 6 available digits will be on the screen.
7. Enter the serial number of the old transmitter. Button 1 will decrease the value of the digit that is flashing by 1, button 2 will increase the value of the digit that is flashing by 1, button 3 will move the flashing cursor to the left, button 4 will move the flashing cursor to the right.
8. Once the serial number is displayed correctly on the screen, press and release button 5.
Screen will display [REPLACING]. If successful, screen will display [OK] and the remote will shut off. If unsuccessful, the screen will display [FAILED].
11) ALARM FAULT CODES – DTK500 UNIT
Fault Severity DTK500
Overspeed Shutdown 2600
Overcrank Shutdown 3 attempts Speed signal lost Shutdown N/A
Water Empty Shutdown Warning
Teleradio lost Shutdown Shutdown
High battery Warning 15
Low battery Warning 8
Weak battery Warning 6
Overpressure Warning Warning
Engine J1939 Various See QR Code